Contents

External Pinsetter Interface Box..................................................... 1


Internal Pinsetter Interface Box (Non-“GS” Series Pinsetters,
Earlier “GS” Series Pinsetter Installations) .................................. 3
Pinsetter Controller PCB .............................................................. 4
Adaptor PCB ................................................................................ 7
“GS” Series Pinsetter Controller .................................................. 9
“GS” Series Pinsetter Setup ....................................................... 11

PCB Replacement Setup ................................................................ 12


Pinsetter Controller PCB ............................................................ 12
Configuration Jumpers (JP1, JP2, and JP3) ......................... 12
Termination Jumper (JP4) .................................................... 12
S1- ID Switch ....................................................................... 13
“GS” Controller PCB ................................................................. 13
Termination Jumper (J8) ...................................................... 13

Cable Diagrams .............................................................................. 14

i
Pinsetter Interface 29
Intentionally Blank

ii30 Pinsetter Interface


External Pinsetter Interface Box
The main purpose of the Pinsetter Interface Box is to connect a scanner,
pinsensor, or non-Direct Connect GS-Series pinsetter and selected pinsetter
signals to the Lane Group Processor (LGP) of a lane pair. The box provides
control for the pinsetter to allow the LGP to turn the machine on and off
automatically, reset the machine when needed, and obtain pinsetter cycle count
information.

The box also routes 28 VAC to power the scanner or pinsensor and allows
them to communicate properly with the LGP. When connected to a Brunswick
“GS” Series pinsetter, the box adapts the communication from the Gamesetter
or Consolidated Low Voltage Box. so it can be understood by the LGP. With
installations that include BowlerTrack, the Pinsetter Interface Box connects
the BowlerTrack PCB to the LGP.

Two interface boxes are currently available. The first is used for non-GS-
Series pinsetters and in earlier GS-Series pinsetter installations. The second is
used for later GS-Series pinsetter installations.

The Interface Box is typically located on a mounting board attached to the


curtain wall or between a pair of pinsetters. Refer to the figure titled External
Pinsetter Interface Box.

External Pinsetter Interface Box


(1) KEYSWITCH (2) DIAGNOSTICS LIGHT (3) MECHANIC OVERRIDE SWITCH
(4) CURTAIN WALL (5) MOUNTING BOARD (6) LATER “GS” SERIES PINSETTER
INSTALLATIONS
(7) NON “GS” SERIES PINSETTER INSTALLATIONS,
EARLIER “GS” SERIES PINSETTER INSTALLATIONS

Pinsetter Interface 1
The function of the components in the Pinsetter Interface Box are:

(1) Diagnostics LED - This light flashes to indicate the operation condition
and setup of the Pinsetter Controller PCB. In older units, this LED is
located on the Pinsetter Controller PCB. On newer interface boxes for
“GS” Series pinsetters, this LED is removed.

Flash Rate Meaning

Switch 8 of S1 is set to the "ON"


Slow
position
Switch 8 of S1 is set to the
"OFF" position and
Medium
communication to the scanner or
pinsensor has been established.
Switch 8 of S1 is set to the
"OFF" position, but
F a st communication to the scanner or
pinsensor has not been
established.

(2) Keyswitch - The keyswitch is present on some interface boxes. If


present, the switch should be disconnected from the Pinsetter Controller
PCB.

(3) Mechanic Override Switch - This switch allows the user to turn the
pinsetter on and off manually in the event of a failure in the system or
the Pinsetter Interface Box. When set to the “scorer control” position,
the LGP will control the on/off operation of each pinsetter. When set to
the “mechanic override” position, both pinsetters will turn on. On newer
interface boxes for “GS” Series pinsetters, this switch has been
removed.

2 Pinsetter Interface
Internal Pinsetter Interface Box (Non-”GS” and Earlier “GS” Series Pinsetter Installations)
Internally, the Pinsetter Interface Box consists of one main circuit board called
the Pinsetter Controller PCB and a main power transformer. When the box is
connected to a Brunswick “GS” Series pinsetter or the BowlerTrack option is
installed, an additional board called the Adaptor PCB is added to the box.
Refer to the figure titled Internal Pinsetter Interface Box.

Internal Pinsetter Interface Box

The functions of the components in the Pinsetter Interface Box are:

(1) Adaptor PCB - This board adapts the communication from the
Gamesetter of a “GS” Series pinsetter or BowlerTrack PCB so it can be
used by the LGP. It is only installed in the Pinsetter Interface Box if a
Brunswick GS-10, GS-92, or GS-96 Pinsetter is being used or if the
BowlerTrack option is installed. For installations after January 2000,
this PCB is located in the BowlerTrack chassis.

(2) Pinsetter Controller PCB - This board is responsible for all of the
functions provided by the interface box.

(3) Power Transformer - The transformer changes the incoming 28 VAC


received from the Secondard Console (Laneworx, Powerworx,
Touchworx) or LGP chassis (Skyworx and Teamworx) to 9.5 VAC.
This voltage is sthen used by the Pinsetter Controller PC to generate 5
VDC.

Pinsetter Interface 3
Pinsetter Controller PCB
The Pinsetter Controller PCB is responsible for all of the functions provided
by the Pinsetter Interface Box. It allows the control of the pinsetter so the LGP
can turn the machine on/off automatically and obtain pinsetter cycle count
information. The board also routes 28 VAC to power the scanner or pinsensor
and allows them to communicate properly with the LGP. Refer to the figure
titled Pinsetter Controller PCB.

Pinsetter Controller PCB

The functions of the comoponents and connectors on the Pinsetter Controller


PCB are:

(1) Adaptor Data (J6) - Connection for the communication cable to the
optional Adaptor PCB.

(2) Adaptor Power (J7) - Connection for the power cable to the optional
Adaptor PCB.

4 Pinsetter Interface
(3) Configuration Jumpers (JP1, JP2, JP3) - These jumpers are used to
set up the PCB for use with a scanner/pinsensor or a “GS” Series
Pinsetter. All jumpers must be set the same.

Jumper Placement
Installation Type
for JP1, JP2, and JP3
All Installations Short Pins 2 and 3 (A)

(4) Diagnostic LED (Light-Emitting Diode) (D4) - This light flashes to


indicate the operating condition and setup of the PCB. In newer
installations, this LED is located on the front panel of the chassis.

Flash R ate Meaning

Swi tch 8 of S1 i s set to the "ON"


Slow
posi ti on
Swi tch 8 of S1 i s set to the
"OFF" posi ti on and
Medi um
communi cati on to the scanner or
pi nsensor has been establi shed.
Swi tch 8 of S1 i s set to the
"OFF" posi ti on, but
F a st communi cati on to the scanner or
pi nsensor has not been
establi shed.

(5) ID Switch (S1) - Set the switches according to the following chart:

Sw itch
Settings
N o.
No.1 No.2
10 Pin Pinsetter Off Off
5 Pin Free Fall Pinsetter On Off
1, 2
(Double Diamond)
5 Pin String Pinsetter Off On
Duck Pin String Pinsetter On On
No. 3 No. 4 No. 5 No. 6 No.7
3-7 All Installations
Off Off Off Off Off
No. 8
8 Adaptor PCB Not Installed Off
Adaptor PCB Installed On

(6) Keyswitch (J5) - Not used. If the keyswitch is present, the cable from
the switch should be disconnected.

(7) Left Pinsetter (J10) - Connection to the left pinsetter. The Controller
PCB controls the left pinsetter on/off and cycle count functions from
this connection.

Pinsetter Interface 5
(8) LLAN (Local Local Area Network) In (J4) - Connection for the cable
that allows the PCB to communicate to the LGP. This connection
allows scores and pinsetter information to be sent to the LGP and allows
the LGP to control pinsetter functions.

(9) LLAN Out (J3) - Connection that allows the LLAN to continue to
additional devices if needed. Usually the TV-Only Monitor LLAN
cables attach here. Refer to (16) Termination Jumper (JP4).

(10) Main Power In (J2) - Connection for 28 VAC coming from the
Secondary Console (Laneworx, Powerworx, and Touchworx) or LGP
(Teamworx and Skyworx) Secondary Transformer.

(11) Main Power Out to Transformer (J11) - Connection for the


transformer located in the Pinsetter Interface Box. 28 VAC is sent to
the transformer from this connection.

(12) Mechanic’s Override Switch (J8) - Connection to the override switch


located on the front of the box. This switch allows the user to turn the
pinsetters on manually.

(13) Right Pinsetter (J9) - Connection to the right pinsetter. The Controller
PCB controls the right pinsetter on/off and cycle count functions from
this connection.

(14) Scanner (J1) - Connection to the scanner or pinsensor (string machine)


that provides 28 VAC power to the scanner/pinsensor and allows the
scanner/pinsensor to communicate with the Pinsetter Interface Box.
Refer to (8) LLAN In (J4).

(15) Secondary Transformer Power In (J12) - Connection to the


secondary side of the transformer located inside the box. 9.5 VAC
power used by the Pinsetter Controller PCB to generate 5 VDC enters at
this connection.

(16) Termination Jumper (JP4) - Jumper used to terminate the LLAN


signal if it does not continue to additional devices. Refer to (9) LLAN
Out (J3). Set the jumper as follows:

Configuration Jumper Placement

No additional devices
Short Pins 1 and 2 (T)
connected to J3 (Terminated)

Additional devices connected


Short Pins 2 and 3 (U)
to J3 (Not terminated)

6 Pinsetter Interface
Adaptor PCB
The Adaptor PCB adapts the communication used by the Gamesetter of a
“GS” Series Pinsetter and/or the BowlerTrack PCB so it can be understood by
the LGP. This board is only installed in the Pinsetter Interface Box for earlier
installations with Brunswick “GS” Series Pinsetter or the BowlerTrack system
is being used on non-”GS” Series pinsetters. Refer to the figure titled Adaptor
PCB (Part No. 57-300199-000).

Adaptor PCB (Part No. 57-300199-000)

The functions of the connections on the Adaptor PCB are:

(1) Adaptor Data (J3) - Connection for the communication cable coming
from the Pinsetter Controller PCB. (J6)

(2) Adaptor Power (J1) - Connection for the power cable coming from the
Pinsetter Controller PCB. (J7)

Pinsetter Interface 7
(3) Diagnostic LED - This light flashes whenever the board is functioning
properly.

Flash R ate Meaning

Swi tch 8 of S1 i s set to the "ON"


Slow
posi ti on
Swi tch 8 of S1 i s set to the
"OFF" posi ti on and
Medi um
communi cati on to the scanner or
pi nsensor has been establi shed.
Swi tch 8 of S1 i s set to the
"OFF" posi ti on, but
F a st communi cati on to the scanner or
pi nsensor has not been
establi shed.

(4) Gamesetter/BowlerTrack PCB (J2) - Connection for communication


to the Gamesetter of a “GS” Series Pinsetter or the BowlerTrack PCB.
If both the Gamesetter and the BowlerTrack PCB are used, this signal is
split by a “Y” cable so it can be routed to both locations.

8 Pinsetter Interface
“GS” Series Pinsetter Controller
The “GS” Series Pinsetter Controller is used exclusively for centers containing
GS-96 and GS-98 Pinsetters that had the scoring system installed between
March 1997 and June 1998. The purpose of this box is to convert the LLAN
(RS-485) information to a format that can be used by the Gamesetter of the GS
machine. Through this communication, pinsetter on/off frame count
monitoring and scoring is accomplished. The box is powered with 28VAC.

“GS” Series Pinsetter Controller

(1) J3 28VAC POWER IN (2) J4 28VAC POWER OUT (3) J5 9.5VAC POWER IN
(4) J2 TO GAMESETTER (5) J8 JUMPER (6) J7 LLAN OUT
(7) J6 LLAN IN (8) HEARTBEAT LED

The functions of the connections on the “GS” Series Pinsetter Controller are:

(1) 28 VAC Power In (J3) - Input for the voltage originating at the
secondary transformer located in the secondary console or the LGP
chassis.

(2) 28 VAC Power Out (J4) - Output for the voltage going to the step-
down transformer located inside the Interface Box.

Pinsetter Interface 9
(3) 9.5 VAC Power In (J5) - Input for the voltage returning for the step
down transformer. This voltage is then changed to +5 VDC on the
board.

(4) J2 to Gamesetter (J2) - Connection for communication to the


Gamemaker connection located on the Pinsetter Gamesetter Box.
Information handled by this communication includes pinsetter on/off,
frame count monitoring, scores, and special cycle information.

(5) LLAN Termination Jumper (J8) - Jumper used to terminate the


LLAN signal if it does not continue to additional devices. Refer to (6)
LLAN Out (J7). Set the jumper as follows:

Configuration Jumper Placement

No additional devices connected


Short Pins 1 and 2 (T)
to J7 (Terminated)

Additional devices connected to


Short Pins 2 and 3 (U)
J7 (Not terminated)

(6) LLAN Out (J7) - Connection for LLAN Communication to additional


devices on a lane pair. Currently the only device that connects to J7 is
the TV Only monitor. If the monitors are not present, the connection is
not used. Refer to (5) LLAN Termination Jumper (J8).

(7) LLAN In (J6) - Connection for LLAN communication to J2 of the I/O


PCB located in the LGP. All information needed by the Pinsetter
Interface to control the machine, as well as the scores, are handled
through this cable.

(8) Heartbeat LED - The Heartbeat LED allows the user to monitor the
communication between the board and the Gamesetter Box. The LED
can have the following flash rates. Refer to (4) J2 to Gamesetter.

Flash Rate Meaning

Flash, Flash, Pause Normal Communication to Gamesetter

Fast Flashing No Communication to Gamesetter

10 Pinsetter Interface
“GS” Series Pinsetter Setup
Since the pinholder switches are used to count the pins, the Gamesetter or
Consolidated Low Voltage Box must be programmed for “double detect”
whenever the Adaptor PCB is used. This is done by moving switch No. 1 of
the configuration switch (SW2), located on the Gamesetter I/O PCB or
Consolidated CPU PCB, to the “off” position. Also, switch No. 2 must be
turned to the “on” position so that the communication can be sent from the
pinsetter through the proper connector. (Refer to the Pinsetter Service Manual
for the setting of switch Nos. 3 and 4.) Refer to the figure titled Gamesetter
I/O PCB Switch Settings.

PCB Switch Settings

(1) SWITCH NO. 1 (2) SWITCH NO. 2 (3) REFER TO THE PINSETTER SERVICE
MANUAL FOR PROPER SETTING
(4) OFF (5) ON (6) GAMESETTER I/O PCB
(7) CONSOLIDATED CPU PCB

The controls at the top of the Gamesetter or Consolidated Low Voltage Box
must also be set properly in order for the system to score correctly. The
keyswitch must be set to the “normal” position. The comline push button
must be engaged so that the light turns on. Refer to the figure titled
Gamesetter Setup.

(1)
COMLINE (2)
DISCONNECT KEYSWITCH

Gamesetter Setup

(1) COMLINE DISCONNECT (2) KEYSWITCH

Pinsetter Interface 11
PCB Replacement Setup

Pinsetter Controller PCB


Whenever the Pinsetter Controller PCB is replaced, it must be set up
(configured) using jumpers and switches located on the PCB. Jumpers that
must be checked include JP1, JP2, JP3, and JP4. Switches that must be set
include switches 1-8 of S1. Refer to the figure titled Pinsetter Controller PCB
(located earlier in this section) for jumper locations and configure the board
according to the following tables.

Configuration Jumpers (JP1, JP2, and JP3)


These jumpers are used to set up the PCB for use with a scanner/pinsensor or a
“GS” Series Pinsetter. All jumpers must be set the same.
Jumper Placement
Installation Type
for JP1, JP2, and JP3
All Installations Short Pins 2 and 3 (A)

Termination Jumper (JP4)


This jumper is used to terminate the LLAN signal if it does not continue to
additional devices. Refer to (9) LLAN Out (J3) (located earlier in this section).
Set the jumper as follows:

Configuration Jumper Placement

No additional devices
Short Pins 1 and 2 (T)
connected to J3 (Terminated)

Additional devices connected


Short Pins 2 and 3 (U)
to J3 (Not terminated)

12 Pinsetter Interface
S1 - ID Switch
Sw itch
Settings
N o.
No.1 No.2
10 Pin Pinsetter Off Off
5 Pin Free Fall Pinsetter On Off
1, 2
(Double Diamond)
5 Pin String Pinsetter Off On
Duck Pin String Pinsetter On On
No. 3 No. 4 No. 5 No. 6 No.7
3-7 All Installations
Off Off Off Off Off
No. 8
8 Adaptor PCB Not Installed Off
Adaptor PCB Installed On

“GS” Controller PCB


When replacing the GS Controller PCB, jumper J8 must be set according to
the following chart.

Termination Jumper (J8)

Configuration Jumper Placement

No additional devices connected


Short Pins 1 and 2 (T)
to J7 (Terminated)

Additional devices connected to


Short Pins 2 and 3 (U)
J7 (Not terminated)

Pinsetter Interface 13
Cable Diagrams

Pinsetter Interface External Cables for Brunswick “A” and A-2 Pinsetters and Skyworx, Teamworx

(1) LANE GROUP PROCESSOR (2) PINSETTER CONTROLLER (3) CCD SCANNER
(4) TO CABLE (57-300300-000) (5) TO TV ONLY MONITOR (6) BOWLERTRACK (OPTIONAL)
(7) ADAPTOR PRINTED CIRCUIT BOARD

Pinsetter Interface External Cables for Brunswick “A” and A-2 Pinsetters and Powerworx, Laneworx, Touchworx

(1) PRIMARY CONSOLE (2) PINSETTER CONTROLLER (3) CCD SCANNER


(4) TO CABLE (57-300300-000) (5) SECONDARY CONSOLE (6) BOWLERTRACK (OPTIONAL)
(7) ADAPTOR PRINTED CIRCUIT BOARD (8) TO TV ONLY MONITOR

14 Pinsetter Interface
Pinsetter Interface External Cables for AMF Pinspotters and Skyworx, Teamworx

(1) LANE GROUP PROCESSOR (2) PINSETTER CONTROLLER (3) CCD SCANNER
(4) TO CABLE (57-300375-000) (5) TO TV ONLY MONITOR (6) BOWLERTRACK (OPTIONAL)
(7) ADAPTOR PRINTED CIRCUIT BOARD

Pinsetter Interface External Cables for AMF Pinspotters and Powerworx, Laneworx, Touchworx

(1) PRIMARY CONSOLE (2) PINSETTER CONTROLLER (3) CCD SCANNER


(4) TO CABLE (57-300375-000) (5) SECONDARY CONSOLE (6) BOWLERTRACK (OPTIONAL)
(7) ADAPTOR PRINTED CIRCUIT BOARD (8) TO TV ONLY MONITOR

Pinsetter Interface 15
Pinsetter Interface External Cables for String Machines (Models P, R, CA-1, M, and S) and Skyworx, Teamworx

(1) LANE GROUP PROCESSOR (2) PINSETTER CONTROLLER (3) PINSENSOR


(4) TO PINSETTER (5) TO TV-ONLY MONITOR (6) BOWLERTRACK (OPTIONAL)
(7) ADAPTOR PRINTED CIRCUIT BOARD

Pinsetter Interface External Cables for String Machines (Models P, R, CA-1, M, and S) and Powerworx, Laneworx, Touchworx

(1) PRIMARY CONSOLE (2) PINSETTER CONTROLLER (3) PINSENSOR


(4) TO PINSETTER (5) SECONDARY CONSOLE (6) TO TV-ONLY MONITOR
(7) ADAPTOR PRINTED CIRCUIT BOARD (8) BOWLERTRACK (OPTIONAL)

16 Pinsetter Interface
Pinsetter Interface External Cables for Brunswick “GS” Series Pinsetters and Skyworx, Teamworx (Earlier Installations)

(1) LANE GROUP PROCESSOR (2) PINSETTER CONTROLLER (3) PINSENSOR


(4) TO PINSETTER (5) TO TV-ONLY MONITOR (6) GAMESETTER AND OR BOWLERTRACK
(7) ADAPTOR PRINTED CIRCUIT BOARD (OPTIONAL)

Pinsetter Interface External Cables for Brunswick “GS” Series Pinsetters and Powerworx, Laneworx, Touchworx (Earlier
Installations)

(1) PRIMARY CONSOLE (2) PINSETTER CONTROLLER (3) TO GAMESETTER AND/OR


BOWLERTRACK
(4) ADAPTOR PRINTED CIRCUIT BOARD (5) SECONDARY CONSOLE (6) TO TV-ONLY MONITOR
(7) TO PINSETTER

Pinsetter Interface 17
Pinsetter Interface External Cables for Brunswick “GS” Series Pinsetters and Skyworx, Teamworx (March 1997 and Later
Installations)

(1) LANE GROUP PROCESSOR (2) GS PINSETTER CONTROLLER (3) GAMESETTER AND/OR BOWLERTRACK
(4) TO TV-ONLY MONITOR

Pinsetter Interface External Cables for Brunswick “GS” Series Pinsetters and Powerworx, Laneworx, Touchworx (March 1997
and Later Installations)

(1) PRIMARY CONSOLE (2) GS PINSETTER CONTROLLER (3) TO GAMESETTER AND/OR


BOWLERTRACK (OPTIONAL)
(4) TO TV-ONLY MONITOR (5) SECONDARY CONSOLE

18 Pinsetter Interface
Primary Console to Pinsetter Interface Local LAN Cable (Part No. 57-300022-000)
(1) DRAIN (2) LOCAL AREA NETWORK A (3) LOCAL AREA NETWORK B
(4) +12 VOLTS DIRECT CURRENT (5) GROUND (6) TO J2 ON PRIMARY CONSOLE
INPUT/OUTPUT PRINTED CIRCUIT
BOARD
(7) TO J4 ON PINSETTER CONTROLLER PRINTED
CIRCUIT BOARD

Secondary Console to Pinsetter Interface 28 VAC (Part No. 57-300023-000)

(1) 28 VOLTS ALTERNATING CURRENT (2) 28 VOLTS ALTERNATING CURRENT RETURN (3) 28 VOLTS ALTERNATING CURRENT
FROM SECONDARY CONSOLE
TRANSFORMER
(4) TO J2 ON PINSETTER CONTROLLER PRINTED
CIRCUIT BOARD

Pinsetter Interface to String Machine (Part No. 57-300024-000)

(1) DRAIN (2) NO CONNECTION (3) TRANSMIT


(4) RECEIVE (5) SCANNER CLOCK (6) GROUND
(7) 28 VOLTS ALTERNATING CURRENT (8) 28 VOLTS ALTERNATING CURRENT RETURN (9) SHIELD
(10) TO J1 ON PINSETTER CONTROLLER PRINTED (11) TO J3 ON STRING INTERFACE (12) TO J6 ON STRING INTERFACE
CIRCUIT BOARD

Pinsetter Interface 19
Pinsetter Controller PCB to TV-Only LLAN (Part No. 57-300031-000)

(1) DRAIN (2) NO CONNECTION (3) LOCAL AREA NETWORK A


(4) LOCAL AREA NETWORK B (5) +12 VOLTS DIRECT CURRENT (6) GROUND
(7) TO OVERHEAD LOCAL AREA NETWORK (8) TO J3 ON PINSETTER CONTROLLER PRINTED
INPUT CIRCUIT BOARD

Frameworx A-2 Pinsetter “Y” Power and Cycle Cable (Part No. 57-300036-000)

(1) CYCLE COUNT (2) AUTOMATIC PINSETTER POWER (3) COMMON


(4) TO CCD SCANNER NEW PINS SOLENOID (5) NO CONNECTION (6) TO J10 ON PINSETTER CONTROLLER
CABLE (57-300300-000) PRINTED CIRCUIT BOARD
(7) TO J9 ON PINSETTER CONTROLLER PRINTED
CIRCUIT BOARD

20 Pinsetter Interface
Scanner to Pinsetter Interface Box Cable (Part No. 57-300147-000)
(1) DRAIN (2) NO CONNECTION (3) TRANSMIT
(4) RECEIVE (5) SCANNER CLOCK (6) GROUND
(7) 28 VOLTS ALTERNATING CURRENT (8) 28 VOLTS ALTERNATING CURRENT RETURN (9) SHIELD
(10) TO J1 ON PINSETTER CONTROLLER PRINTED (11) TO J67 ON CCD SCANNER (12) TO J1 ON CCD SCANNER
CIRCUIT BOARD

Pinsetter Interface to “GS” Series Cable (Part No. 57-300148-000)

(1) DRAIN (2) GROUND (3) SIGNAL B


(4) SIGNAL A (5) +12 VOLTS DIRECT CURRENT (6) SHIELD
(7) NO CONNECTION

Pinsetter Interface Adaptor Power Cable (Part No. 57-300149-000)

(1) TO J7 ON PINSETTER CONTROLLER (2) TO J1 ON ADAPTOR PRINTED CIRCUIT BOARD (3) +5 VOLTS DIRECT CURRENT
PRINTED CIRCUIT BOARD
(4) GROUND (5) +24 VOLTS DIRECT CURRENT

Pinsetter Interface 21
Pinsetter I/O PCB to Adaptor PCB Data Cable (Part No. 57-300150-000)

(1) TO J1 ADAPTOR PRINTED CIRCUIT BOARD (2) TO PINSETTER CONTROLLER PRINTED CIRCUIT BOARD

LGP to Pinsetter Interface Box LLAN Cable - Skyworx, Teamworx (Part No. 57-300151-000)

(1) TO J2 ON LANE GROUP PROCESSOR (2) TO J4 ON PINSETTER CONTROLLER PRINTED (3) DRAIN
INPUT/OUTPUT PRINTED CIRCUIT BOARD CIRCUIT BOARD
(4) LOCAL AREA NETWORK A (5) LOCAL AREA NETWORK B (6) +12 VOLTS DIRECT CURRENT
(7) GROUND (8) SHIELD

LGP to Pinsetter Interface Box Power Cable - Skyworx, Teamworx (Part No. 57-300152-000)
(1) TO LANE GROUP PROCESSOR SCANNER (2) TO J2 ON PINSETTER CONTROLLER PRINTED (3) 28 VOLTS ALTERNATING CURRENT
TRANSFORMER CIRCUIT BOARD
(4) 28 VOLTS ALTERNATING CURRENT RETURN

22 Pinsetter Interface
Pinsetter Interface Controller Wiring Diagram (Part No. 57-300179-4xx)

(1) ADAPTOR DATA CABLE (2) PINSETTER CONTROLLER PRINTED CIRCUIT (3) TRANSFORMER MOUNTED TO INSIDE
BOARD OF BASE ENCLOSURE
(4) ADAPTOR PRINTED CIRCUIT BOARD (5) TO ADAPTOR PRINTED CIRCUIT BOARD, (6) OVERRIDE SWITCH MOUNTED ON
POWER CABLE CONNECT TO J1. SIDE OF BASE ENCLOSURE
(7) BASE ENCLOSURE WALL (8) NUT (9) CONNECTOR
(10) LIGHT-EMITTING DIODE MOUNTED ON (11) KEYSWITCH MOUNTED ON SIDE OF (12) TO ADAPTOR PRINTED CIRCUIT
SIDE OF BASE ENCLOSURE BASE ENCLOSURE BOARD, CONNECT TO J3.

Pinsetter Interface Controller Override Switch Cable (Part No. 57-300289-000)


(1) NUMBERS ARE FOR REFERENCE ONLY (2) TO J8 ON PINSETTER CONTROLLER PRINTED
CIRCUIT BOARD

Pinsetter Interface 23
Pinsetter I/O Keyswitch Cable (Part No. 57-300290-000)
(1) POSITION 1 (2) POSITION 7 (3) TO J5 ON PINSETTER CONTROLLER
PRINTED CIRCUIT BOARD

Pinsetter Interface Controller Transformer (Part No. 57-300291-000)


(1) NO CONNECTION (2) TO J12 ON PINSETTER CONTROLLER (3) TO J11 ON PINSETTER CONTROLLER
PRINTED CIRCUIT BOARD PRINTED CIRCUIT BOARD
(4) PRIMARY 28 VOLTS ALTERNATING (5) SECONDARY 9.5 VOLTS ALTERNATING
CURRENT CURRENT

Cycle Count for “GS” Series Pinsetter Cable (Part No. 57-300298-000)
(1) NO CONNECTION (2) TO J9 OR J10 ON PINSETTER (3) TO P6 ON HIGH VOLTAGE BOX
CONTROLLER PRINTED CIRCUIT BOARD

24 Pinsetter Interface
A-2 Pinsetter New Pins Solenoid to Low Voltage Box (Part No. 57-300299-000) (New Universal Voltage)
(1) ASSEMBLE TO 12-PIN MOLEX PLUG IN NEW (2) COMMON (3) 44°/144° NORMALLY OPEN
PINS SOLENOID BOX (57-214174-000) PER
POSITION NUMBER SHOWN
(4) 0° NORMALLY OPEN (5) GROUND (6) TO RELAY T2 ON (57-215005-000)
(7) TO PIN NO. 2 SOLENOID ON (8) GROUND LUG
(57-214234-000)

Pinsetter Interface 25
A-2 Pinsetter New Pins Solenoid to Low Voltage Box (Part No. 57-300299-000) (Japanese Pinsetter)
(1) ASSEMBLE TO 12-PIN MOLEX PLUG IN NEW (2) COMMON (3) 44°/144° NORMALLY OPEN
PINS SOLENOID BOX (57-214174-000) PER
POSITION NUMBER SHOWN
(4) 0° NORMALLY OPEN (5) GROUND (6) TO RELAY T2 ON (57-215005-000)
(7) TO PIN NO. 2 SOLENOID ON (8) TL1 BROWN WIRE
(57-214234-000)

26 Pinsetter Interface
A-2 Pinsetter New Pins Solenoid to CCD Scanner (Part No. 57-300300-000)
(1) TO NEW PINS SOLENOID LANE 1 (2) TO NEW PINS SOLENOID LANE 2 (3) NO CONNECTION
(4) CYCLE COUNT ODD LANE (5) AUTOMATIC PINSETTER POWER ODD LANE (6) COMMON
(7) NEW PINS SOLENOID VCC (8) NEW PINS SOLENOID GROUND (9) SWITCH CLUSTER GROUND
(10) SECOND BALL (11) 0° SWITCH (12) 44°/144° SWITCH
(13) CYCLE COUNT EVEN LANE (14) AUTOMATIC PINSETTER POWER EVEN LANE (15) TO CABLE (57-300036-000)
(16) TO CCD SCANNER DATA PROCESSOR (J8) (17) TO CCD SCANNER DATA PROCESSOR (J9) (18) LEFT
(19) RIGHT

Pinsetter Interface 27
AMF Interface to CCD Scanner (Part No. 57-300375-000)

(1) TO AMF INTERFACE PRINTED CIRCUIT BOARD (2) NO CONNECTION (3) POWER DIRECT CURRENT, LANE 1
(4) GROUND AMF, LANE 1 (5) POWER DIRECT CURRENT, LANE 2 (6) GROUND AMF, LANE 2
(7) FOUL, LANE 1 (8) FOUL, LANE 2 (9) SWEEP UP, LANE 1
(10) TABLE SWEEP, LANE 1 (11) POWER, LANE 1 (12) SECOND, LANE 1
(13) TABLE SWEEP, LANE 2 (14) POWER, LANE 2 (15) SECOND, LANE 2
(16) GROUND SCORER, LANE 2 (17) GROUND SCORER, LANE 1 (18) SWEEP UP, LANE 2
(19) TO CABLE (57-214895-000) (20) TO J6 ON SCANNER PRINTED CIRCUIT (21) TO J8 ON SCANNER PRINTED CIRCUIT
BOARD BOARD
(22) TO J9 ON SCANNER PRINTED CIRCUIT BOARD

Universal Interface Adaptor String Machine (Part No. 57-900376-000)


(1) NO CONNECTION (2) TO AUTOMATIC PINSETTER POWER (3) TO AUTOMATIC PINSETTER
CYCLE COUNT
(4) POWER + (5) POWER - (6) CYCLE COUNT +
(7) CYCLE COUNT - (8) TO J10 OR J9 ON PINSETTER
CONTROLLER PRINTED
CIRCUIT BOARD

28 Pinsetter Interface