WATERMARK, HANOI WESTLAKE REAL ESTATE DEVELOPMENT JSC TECHNICAL SPECIFICATION HEATING, VENTILATION & AIR CONDITIONING SERVICES 5.7 AXIAL FLOW FANS. (a) General ‘Supply and install axial flow fans as specified on the drawings scheduled later in this section of the specification, Fans shall have limit load characteristics, In case of fans built into proprietary ine equipment, the manufacturers’ standard construction may be accepted. Tenders shall state in what manner the item offered differs from this specification Fans shall be tested as part ofthe specified tests on the completed system. Resilient bearing mountings shall be used when they are available and suitable. Blades shall be of aerofoil section made of aluminium or glass fibre reinforced plastic. They shall be adjustable in pitch angle and positively locked into the hubs. By adjustment of pitch angle alone and without changing the motor, fans shall be capable of delivering the specified flow rate at system resistances from at least 10% below to at least 10% above the contractor's assessment (b). Materials ‘The materials shall be as follows: Fan Location Shalt Casing Exposed to weather Stainless Sieal ‘ther Location High Tense Stoo ‘Materials shall conform to the following standards ‘Wid Stee! Sheat ‘ASI67O & ASIG7S Stainless Stoel Shoot BSS 970-ENSBA or ENSBB (Equiv. Comstoe! 302, 321) “High Tensile Stool Shating AS7 S104 orBSS970-ENS ‘Sainiess Stee! Shating BSS 970-ENS7 ENSAB (Equiv. Comstee! 431) (©) Casing Fan casing shall be of heavy material and at least the length of the fan/motor assembly. Casing shall be fitted with mounting flanges at both ends and also with drilled matching flanges. Provide terminal box and access panel to the moving parts in accessible positions on the casing, (a). Shaft Drive shafts shall be designed such that the first critical speed of the shaft is at least 130% of the normal operating speed of the fan. (e) Bearings ‘All beatings shall be semi-self aligning ball or roller type selected for a life ‘expectancy of 300,000 hours. Tolerances shall be such as to ensure specified noise levels are not exceeded. Axial thrusts, where shafts exceed 30mm shall be taken by ball thrust bearings. In other cases, deep-groove ball bearings may bbe used. All bearing housings shall be dowelled and have individually identfied packer plates. Bearings shall be sealed with felt or “Gaco” type seals with provision for relieving excess grease pressure. All bearings shall have grease pipes and nipples mounted in easily accessible positions on the casing. Connell Wagner FILE @:00! BUILDINGSI001 AO Al (WEST LAKE APARTNENT), ENGINEERINGIMAE'\SPECIFICATIONSINECHIMVAC 'SPEC REVOt (ENG)DOG | 0910712010] PAGE 32 WATERMARK, HANOI WESTLAKE REAL ESTATE DEVELOPMENT JSC TECHNICAL SPECIFICATION HEATING, VENTILATION & AIR CONDITIONING SERVICES 6 (9) (hy Connell Wagner Belt Drives (where scheduled) Bolt drives shall be by matched vee belt, with 2 minimum of 2 belts per pulley. Provide approved means to facilitate adjustment. Provide and fit an approved easily removable belt and pulley guard. Drives shall have a power rating 30% in excess of the motor power rating. Carefully align the drive to yield minimum noise. Belt guard shall be fully enclosed inside the casing and also outside where exposed to the weather. Arrange for easy replacement of bets. Balancing Allrotating parts shall be fully statically and dynamically balanced, Vibration Isolation Each fan/motor assembly shall be mounted on combination springiribbed neoprene mounts so located that they deflect uniformly. Springs shall have a ‘mean coil diameter not lass than 80% of the loaded spring length. Springs shall be capable of 150% of the specified static deflection. Mounts shall be provided with lock-nutted levelling screws. Stalic deflections shall be as set out below: Revise Flooron Sold Suspended floor Suspended floor ground spanupt9m span 9m and above ‘Above 8 980 250) 45.0 608 80 63.0 oy 506 00 63.0 700) Provide inertia block as necessary. Where fans are mounted with their axis horizontally and where necessary to prevent axial movement from stretching or compressing ductwork flexible Connections, end thrusts shall be taken by spring mountings fixed to rigid angle iron frames. These mountings shall be equal to Mason SLF with acoustical isolation cups and a minimum deflection, when in operation at full system resistance, of not less than 50mm. Flexible duct connections shall be arranged to suit with a metal support ring inside the inlet of the flexible to prevent the flexible being sucked into the duct. (Motor Motor speeds shall not exceed 25 revisec Motors shall have a rated capacity 100% above the duty specitied (i) Connections Connections to ductwork shall be by means of slack flexible connectors fabricated from PVC coated fabric of mass nat less than 570 grim free lengths shall be not less than 70mm (ii) Transportation During transpor, impellers shall be adequately supported to prevent brine ling of ball andor roler bearings. (@) Corrosion Protection Surfaces shall be treated as set out below: Tem Location ‘Other location Exposed to weather FILE @:00! BUILDINGSI001 AO Al (WEST LAKE APARTHENT):, ENGINEERINGIMAE'\SPECIFICATIONSINECHIMVAC 'SPEC REVOt (ENG)DOG | 0910712010] PAGE 33 WATERMARK, HANOI WESTLAKE REAL ESTATE DEVELOPMENT JSC TECHNICAL SPECIFICATION HEATING, VENTILATION & AIR CONDITIONING SERVICES Key to methods is as follows: Method A Hot dip galvanise, if not too large, otherwise molten aluminium spray 0.10mm thick followed by one coat tar-epoxy enamel Method 8 ‘Molten aluminium spray 0.10mm thick followed by one coat of tar-epoxy enamel Method © Giean down, prime with zinevich paint, apply one undercoat and one top coat of approved gloss enamel Method D Hot dip galvanise i not too large, otherwise molten aluminium spray 010mm thick folowed by one undercoat and one coat approved gloss enamel Connell Wagner FILE @:00! BUILDINGSI001 AO Al (WEST LAKE APARTNENT), ENGINEERINGIMAE'\SPECIFICATIONSINECHMVAC 'SPEC REVOt (ENG)DOG | 0910712010] PAGE 34

Vous aimerez peut-être aussi