Académique Documents
Professionnel Documents
Culture Documents
PUMP GATETM
Technology : Pump Gate System Technology which does not require Regular Pump Station
PUMP GATE"
Pump Gatem Function Land for Pump Station Construction Cost Maintenance Cost Construction Period Existing Flood Gate Electrical Capacity Actuator Emciency Complete Automation
required.
: Existing gate structure and gate can be re-utilized.
: 30%
: Actuator efficiency increased of 100% than conventional actuator. : Complete automatic operation can be materialized.
Pump catem series has been developed as a new drainage facility that integrates the pump and the gate into one system.
Having been erected in the existing water channels, Pump Gate is no longer necessary t o provide large scale sump pit area and pump station work.
No sump pit and pumping station are required
No land for sump and pumping station are required As pump is integrally equipped with gate, Maintenance of Pump Gate is very simple and easy As no pump station is required, the structural work will be minimal. Construction of Pump Gate can be done in a short period of time. To compare the cost of the ordinary pump station with Pump Gate, great reduction can be achieved.
--
,~zz,=:=>-.~
,
Normal
inside
>
When exterior water level is lower than that of interior water, Pump Gate and Screen will be closed and opened so that gravity flow will discharge interior water toward outside.
>
When exterior water level goes higher than that of interior water, Pump Gate will be completely closed. Then, Screen will be closed, If interior water level reaches to the pre-determined water level, Pump and Screen will be automatically operated in order to forcibly discharge interior water toward outside. When exterior water level drops lower than that of interior water, Pump Gate and screen will be opened so that gravity flow will discharge interior water toward outside.
PUMP GATE"
A
2000(1150)
B
850(-)
c
3600
D
1400
E
800
G
1100
2PNCTS CC250 STS42OJ2 CC250 CAC402 / SSC13 CC250 CC250 TURBINE OIL STS304 SM45C / STS304 55400 / STS304 NEOPRENE STS304 FC250
PUMPGATE"
DESCRIPTION CABLE HOLDER SUCTION COVER SUCTION BOWL THERMAL PROTECTOR MOTOR FRAME MA1N SHAFT WATER DETECTOR LUBE OIL GUIDE MECHANICAL SEAL SHAFT SLEEVE ROTOR DISCHARGE BOWL SPINDLE SEAL RUBBER ROLLER GATE LEAF FALP VALVE MAIN ROLLER ROLLER GUIDE
MATERIALS
ZPNCTS STS304 I 55400 GC250 CC250 STS410 TURBINE OIL GC250 ST5304 ssc13 1 CAC402 CC250 SM45C I STS304 NEOPRENE 55400 I STS304 55400 1 ST5304 STS304 STS304
PUMP GATE"
Pump Gate"
I 2 S
-& d
4
t r r a Q 1 0 Capacity (rn3/rnin)
F/
I5
15
Head (m)
4 D 6 7 8 9 1 0 Capacity (rn3/rnin)
As this chart being provided an example based on 3m total head, the detailed calculation will indicatethe results based on the actual data
Capacity (rn3/rnin)
250
300
3 5 0 . 4 0 0 .
509
g o o .
7 0 6 . 8 0 0
Head (rn)
Power
PUMP GATETM