ISSUE 1.0
Objectives
SG7000
Perform SG7000 data setting correctly
Referrence material
31130979-Package
of Documents-U-SYS SG7000
V100R001(V1.10)
Course Contents
Basic information
SG7000 Client Software installation Firstly we need install DAO program. Serial number of SG7000 software is sg7000 BAM IP address IP address of BAM should be 172.6.0.6 and 172.8.0.8 HSYS default IP address is :172.6.1.6 and 172.8.1.8
Signaling management
MTP3 management SCCP management SCTP parameter setting M3UA and M2PA management
After Loading Finished Query The Hardware/MTP-Links/M3UA-Link Status Tracing The Message in MTP-Links and M3UA-Link
You can set offline mode firstly ,add frame/board in BAM, then FMT data, then Download all hardware data to Host.
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal
Sometimes if there are too much alarm message, You dont want be disturbed, you can close alarm Output temporarily.
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal
Destination Signaling Point Code ADD N7DSP (DPC) Routing Context Work Mode in SG7000 Local Entity Type in SX3000 ADD M3AS ADD M3ASSOS (SGP)
Remote IP address
Local port number Remote port number C/S model
ADD RIP
ADD M3ASSO ADD M3ASSO ADD M3ASSO (Server)
ADD FECFG
ADD M3LNK ADD M3LNK ADD M3LNK (Client)
Parameter Destination Signaling Point Code (DPC) Signaling Link Code (SLC) Start Time Slot (Ts) Number of Combination Ts (Specially for 2M Link)
SG7000 ADD N7DSP ADD N7LNK ADD N7LNK ADD N7LNK -----
PSTN Switch
Course Contents
E P I I S B P U
E P I I S B P U
E P I I S B P U
E P I I S B P U
V I E B S B P I
SH CB BI UU HH CS OY MS
H S C U
H B I U H S Y S
H S C U
S C B U
V I E B
E P I I S B P U
C K I I
C K I I A L U I
Front board
HS CB OP MI
-----
255.255.255.0
Gateway
SP code(14 bits) Signaling mode
--0x97B (2427)
Basic Configuration
Step Step 1: Add Board Step 2: Add the local IP address (SBPI) Step 3: Add EPII/ SEPU work status Step 4: Add CKII work status Step 5: Set the local office information Command ADD BRD ADD LIP ADD TRUNKSTAT ADD CKISTAT SET OFI
Step 6: Add the remote IP address Step 7: Add the remote IP address combination
ADD N7DSP index number [national network code] [STP] [adjacent flag] [route selection field] [SCCP function] [timer index] ADD M3AS index number [SG work mode] [destination point code index] [routing context]
ADD M3ASSOS index number [adjacent application server index] [work mode] ADD M3RT index number [application server index] [association set index]
ADD M3ASSO index number [shelf number] [frame number] [board number] [board association number] [local IP combination index] [remote IP combination index] [C/S mode] [association set index] Confidential Information of Huawei. [active_standby flag] No Spreading without Permission.
ADD RIPC index number [remote IP address index 1] [remote IP address index 2]
Step
Step 1: Add the Destination Signaling Point Step 2: Add the MTP link set Step 3: Add the MTP route Step 4: Add two MTP link
Command
ADD N7DSP ADD N7LKS ADD N7RT ADD N7LNK
Course Contents
Maintenance system
Maintenance Command(1)
Operation Activate the MTP Link Set Deactivate the MTP Link Set Activate the MTP Link Deactivate the MTP Link Active M3UA Association Command ACT N7LKS DEA N7LKS ACT N7LNK DEA N7LNK ACT M3ASSO
DEA M3ASSO
BKP DB
SET SFTSWT: MODE=ALL, VAL=224;
Course Contents
ADD M3RT
ADD RTANA ADD CNACLD
Summary