Course Target

Master ZXMP S200 Feature Master ZXMP S200 Hardware

Contents

Product Profile System Function Hardware Structure Board Introduction

ZXMP S200 Profile

ZTEs SDH based multi-service node equipment family (Unitrans ZXMP family) can support all applications at the core layer, convergence layer and access layer. It provides users with future-oriented and integrated solutions for metro area network (MAN). ZXMP S200 is a kind of SDH transmission equipment for multi-service access, supporting the rate up to STM-4. Besides serving as the integrative transmission equipment in GSM, CDMA or 3G base stations, it can also access multi-services for customers in buildings or communities as well as private line services for business customers. Moreover ZXMP S200 can replace existing PDH equipment for transmission.
ZXMP S390 ZXMP S385 ZXMP S380 ZXMP S385 ZXMP S380 ZXMP S330

ZXMP ZXMP ZXMP ZXMP ZXMP ZXMP

S330 S325 S320 S310 S200 S100

ZXMP S200 Product Feature


Powerful Networking capacity

Strong capacity of Service access

Support 10G Cross-connection capacity Support four optical direction with the rate of STM-622, strong networking capacity,support ring with chain and ring with ring

Support many kinds of service, such as PDH,SDH,FE,V.35,RS232 /RS485/RS442,SHDSL,AI/DI

high integration, strong Expansion capability

ZXMP S200 Product Features

Flexible configuration, easy maintenance


Technology of single fiber bi-directional transmission saves fiber resource Support SFP module, confiugre easily Support E1-ECC, realize interconncetion with different vendors

only1U ,high integration, saving space Support 155M and 622M, flexible configuration support extension slot

Contents

Product Profile System Function Hardware Structure Board Introduction

ZXMP S200 System Features

Small Size and Compact Structure

ZXMP S200 has small size and high integration. Equipped with various mounting flanges, ZXMP S200 can be installed on the desktop, hung on the wall, or in an IEC, ETS standard 19-inch cabinet and transmission outdoor cabinet. All interfaces are located at the front, by which, operation and maintenance of the equipment is very convenient As the structure is compact, so It needs less space for accommodation.

ZXMP S200 System Features

Abundant Service Functions

ZXMP S200 can access multi-services, including traditional SDH services and data services. S200 supports two kinds of main control board, including SMB and SMC, the follow table is the cross-connect capacity
Board Type Space Division Capacity Time Division Capacity

SMB
SMC

3232 VC4
6464 VC4

10081008 VC12
20372037 VC12

ZXMP S200 System Features

Abundant Service Functions

The service interfaces and corresponding maximum access capacities provided by ZXMP S200 with SMB
Max. Capacity (Channel)
4

Interface
SDH optical interface

Remark
ZXMP S200 supports 4 channels of STM-1 and 2 channels of STM-4 optical interfaces at most. Thus, the allowable SDH interface combinations are as follows: 4 STM-1 or 2 STM-1 + 2 STM-4 or 3 STM-1 + 1 STM-4 -

E1/T1 electrical interface E3/T3 electrical interface FE interface

42

E3 or T3 rate is supported via the EMS.

FE interface include FE electrical interface and FE optical interface. The allowable combinations of 8 channels of FE interfaces are as follows: 4 FE (electrical) + 4 FE (optical) or 8 FE (electrical) The main board provides 4 channels of FE interfaces, and the SEC board provides another 4 channels of FE electrical interfaces, which supports L2 switch.

ZXMP S200 System Features (To be continued)


Interface Max. Capacity (Channel)
2 N is an integer from 1 to 31

Remark

V.35 data interface (N 64 kbit/s) Audio interface Data interface

6 6 or 3

Set the interface type is two-line or four-line via EMS, or set the output electrical level gain. The ZXMP S200 supports 6 RS232 interfaces or 6 RS485 interfaces or 3 RS422 interfaces. The interface type can be set via the EMS. -

Orderwire telephone interface TRK interface SHDSL interface

1 4

ZXMP S200 System Features

Abundant Service Functions

The service interfaces and corresponding maximum access capacities provided by ZXMP S200 with SMC
Max. Capacity (Channel) 4 4 42 Remark Each of the optical interfaces can be set to access the STM-4 or STM-1 signal. The main board provides 21 x E1/T1, besides, the plug-in board ET1 can provide another 21 x E1/T1. FE interface include FE electrical interface and FE optical interface. The allowable combinations of 8 channels of FE interfaces are as follows: 4 FE (electrical) + 4 FE (optical) or 8 FE (electrical) The main board provides 4 channels of FE interfaces, and the SEC board provides another 4 channels of FE electrical interfaces, which supports L2 switch. N is an integer from 1 to 31. Set the interface type is two-line or four-line via EMS, or set the output electrical level gain.

Interface SDH optical interface STM-1 electrical interface E1/T1 electrical interface FE interface

V.35 data interface (N 64 kbit/s) Audio interface

2 6

ZXMP S200 System Features (To be continued)

Interface Data interface

Max. Capacity (Channel) 63 ZXMP S200 can provide:

Remark

6 RS232 interfaces or,


6 RS485 interfaces or, 3 RS422 interfaces. The interface type can be set on the EMS. Orderwire telephone interface TRK interface SHDSL interface 1 1 4 -

ZXMP S200 System Features

Abundant Service Functions (to be continued)

ZXMP S200 supports E1/T1 and E3/T3 mapping and multiplexing structure specified by ITU-T recommendations,

In addition, with the SMC board, SDH optical interfaces of ZXMP S200 also support the application of single fiber bi-directional transmission of STM-1/4 optical signal, which is a fiber-saving solution to transport the receiving signal and transmitting signal in a same fiber ZXMP S200 can act as a terminal multiplexer (TM), add/drop multiplexer (ADM) or a regenerator (REG) depending on the actual networking requirements. It supports point-to-point, chain and ring networking modes.

ZXMP S200 System Features

Perfect Network-Level Protection

At the Multiplex Section (MS) layer, ZXMP S200 supports the following MS protection modes:

ZXMP S200 System Features

Perfect Network-Level Protection (to be continued)

At the path layer, ZXMP S200 supports the Sub-Network Connection (SNC) protection modes, such as SNC (I) protection at the level of VC12/VC3 and SNC (N) and SNC (I) protection at the level of VC4. The SNC protection complies with ITU-T G.841 and G.842 recommendations. The following table lists the alarms that will trigger the SNC protection switching.

ZXMP S200 System Features

Powerful Overhead Configuration Capability

The service unit of ZXMP S200 separates the SOH and payloads in SDH frames, combines the overhead bytes into standard overhead bus and then forwards them to the overhead unit. The overhead bus not only includes the management, orderwire and switching bytes complying with ITU-T recommendations, but also loads orderwire and data services into idle overhead bytes. The overhead unit can cross-connect overheads to any port according to the configuration in the EMS. The minimum cross-connect granularity is byte

ZXMP S200 System Features

Multiple Power Supply Input Modes

S200 supports multiple kinds of power supplies, including AC 110 V/220 V DC -48 V DC +24 V. When DC power supply is used, ZXMP S200 supports the dual-input mode, that is, dual paths of DC power supply are input to the equipment for protection. Accordingly, the EMS indicates the input status (normal or alarm) of each path of the two power supply inputs. S200 adopts concentrated power supply mode.

ZXMP S200 System Features

Various Alarm Modes

S200 supports the alarms in visible and audible modes. Indicators on the main board use different colors to indicate critical, major and minor alarms. Indicators on plug-in cards are used to indicate whether the cards report an alarm. In addition, ZXMP S200 provides one alarm input interface and one alarm output interface, to support four alarm inputs (on-off signal inputs) and two alarm outputs (on-off signal outputs).

ZXMP S200 System Features

SSM-based Timing Synchronization Processing

S200 has multiple synchronous timing sources

internal timing source line timing source tributary timing source


external timing source. one external timing source (2 MHz or 2 Mbit/s) all of the extracted clocks from optical interfaces and STM-1 electrical interface (i.e. four line extracted clocks) two tributary clocks extracted from tributary 1 and 2.

S200 supports

S200 supports the processing of the synchronization status byte S1. It also identifies timing quality with synchronization status message (SSM). By this way, NEs can select the synchronous path with the highest quality level, to ensure the network synchronization performance and avoid possible timing loop caused by timing reference switching.

ZXMP S200 System Features

Online Download and Upgrade of Board Software

The main board and plug-in cards of ZXMP S200 support remote online download and upgrade of board software, including application and logic programs. Not interrupted traffic during the download of application programs makes the maintenance and upgrade of the equipment more convenient and guarantees the reliability during system upgrade. Only downloading logic programs may cause transient interruption of traffic.
Realize remote online download of board software Realize convenient maintenance and upgrade of software
.

ECC ZXMP ZXMP

ECC ZXMP

ECC
ZXMP

ZXMP S200 System Features

Good Network Adaptability

Provides network management channels suitable for hybrid networking Different SDH equipment manufacturers define the DCC (data communication channel) bytes and process them in different ways. Due to this, network management information interconnection may be impossible in a hybrid network consisting of equipment provided by different manufacturers. S200 adopts DCC bytes as embedded control channel (ECC) for transmitting network management information. In addition, timeslots of E1 tributaries can also be used as ECC. Thats ,the network management information is added in the SDH payload, and then transmitted transparently through other SDH equipment. Thus the integrated network management in hybrid network is implemented.

Contents

Product Profile System Function Hardware Structure Board Introduction

Cabinet

300mmDx 600mmWx 2600mmH 300mmDx 600mmWx 2200mmH 300mmDx 600mmWx 2000mmH


indicator name Turn on Red lighter Main alarm indicator as the equipment has critical alarmgenerally accompanied by a warning sound main alarm in current equipment Current power supply is normal status Turn off no critical alarm in current equipment

Yellow lighter Green lighter

Normal alarm indicator Power indicator

no main alarm in current equipment current power supply is interrupted

Cabinet and Sub-rack


S200 Can be installed in the 19-inch cabinet, and also can be installed in the European standard cabinet
Cabinet with 300 mm deep, operation in the front, support back to back installation Only 1 U height subrack ,considering arrangement of wire, 1u space need to be obligated As power distribution unit supports 6 air-switch at most, so each cabinet can be installed 6 sets of S200

Equipment Structure

ZXMP S200, designed as a platform, strictly complies with related ITU-T recommendations and China national standards. It provides a main board for accessing various services.
By different types of power module and service interface, composed of multiple configuration, meeting different user requirements. S200 is composed of chassismain boardpluggable boardaccording to actual situationspower modulesfan module and so on. size442mm45.0mm240mm

1.fan module 3.expansion slot 5.4 FE interface in main board 7.E1 interface in main board

2.power interface 4.STM-1/4 optical interface 6.RS232/LCT/NMS QX/alarm input

ZXMP S200 System Structure

ZXMP S200 consists of the hardware system and the network management software system, which are independent of each other while working in a coordinated way.

ZXMP S200 Hardware System

Contents

Product Profile System Function Hardware Structure Board Introduction

ZXMP S200 Board List


No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Board Code SMCxD75E SMCxD75T SMCxF75E SMCxF75T SMCxD120E SMCxD120T SMCxF120E SMCxF120T SMCxD100E SMCxD100T SMCxF100E SMCxF100T SMBxD75E0 SMBxD75T0 SMBxF75E0 SMBxF75T0 Description System Main Center of Dual optical and 75 Eight E1 System Main Center of Dual optical and 75 Twenty-one E1 System Main Center of Four optical and 75 Eight E1 System Main Center of Four optical and 75 Twenty-one E1 System Main Center of Dual optical and 120 Eight E1 System Main Center of Dual optical and 120 Twenty-one E1 System Main Center of Four optical and 120 Eight E1 System Main Center of Four optical and 120 Twenty-one E1 System Main Center of Dual optical and 100 Eight T1 System Main Center of Dual optical and 100 Twenty-One T1 System Main Center of Four optical and 100 Eight T1 System Main Center of Four optical and 100 Twenty-One T1 System Main Board of Dual optical and 75 Eight E1 S200 System Main Board of Dual optical and 75 Twenty-one E1 S200 System Main Board of Four optical and 75 Eight E1 S200 System Main Board of Four optical and 75 Twenty-one E1 S200

ZXMP S200 Board List


No. 17 Board Code SMBxD120E0 Description System Main Board of Dual optical and 120 Eight E1 S200

18
19 20 21 22

SMBxD120T0
SMBxF120E0 SMBxF120T0 SMBxD100E0 SMBxD100F0

System Main Board of Dual optical and 120 Twenty-one E1 S200


System Main Board of Four optical and 120 Eight E1 S200 System Main Board of Four optical and 120 Twenty-one E1 S200 System Main Board of Dual optical and 100 Eight T1 S200 System Main Board of Dual optical and 100 Twenty-One T1 S200

23
24 25 26 27 28 29

SMBxF100E0
SMBxF100F0 PWA PWB PWC IBB IBBZ

System Main Board of Four optical and 100 Eight T1 S200


System Main Board of Four optical and 100 Twenty-One T1 S200 -48 V PoWer module +24 V PoWer module 110 V/220 V PoWer module 2 Mbit/s BITS interface board 2 MHz BITS interface board

ZXMP S200 Board List


No. 30 Board Code ET1-75 Description 21-channel E1 Electrical Tributary board75

31
32 33 34 35 36 37 38 39 40 41 42

ET1-120
TT1-100 EIE3 V35B TFEx4 TFEx4B AI OW SDB SEC MB FAN

21-channel E1 Electrical Tributary board120


21-channel T1 Electrical Tributary board100 Electrical Interface of E3/T3 2-channel V.35 data interface Board 4-channel Transparent-transmission Fast Ethernet electrical interface board 4-channel Transparent-transmission Fast Ethernet optical interface board Audio Interface board Order Wire board 4xSDB interface board 4xFE Enhanced Smart Ethernet board Mother Board FAN board

Main Board

Function description

The main board of ZXMP S200 integrates the functions of NCP, aggregate, tributary, cross-connect, clock, and Ethernet service processing. In addition, it supports the temperature detection function. Set the upper and lower temperature thresholds on the EMS, once the temperature is over threshold, the board will report an alarm. ZXMP S200 supports two different main board types: SMB and SMC. They have the same design and differ in interface types and interface quantities
12 14 16 18 13 15 17

11 1 3 5 7 9

20 2 4 6 8 10 19 21

22 24 26 23 25

Main Board

By the different functions of boardthe two boards are composed of these units

SMC

SMB

NE control processorNCP Optical interface unit STM-1 electrical unit Tributary unit Cross-connect unit Overhead unit ECC-2M unit Clock unit Micro control unitMCU

NE control processorNCP Optical interface unit Tributary unit Cross-connect unit Ethernet interface unit Overhead unit ECC-2M unit Clock unit Micro control unitMCU

NCP Unit

Provide Qx interface, through which the EMS implements the configuration and management of the NE, Provide ECC to implement the communication between the NEs, Issue the configuration commands to the optical interface unit, tributary unit and Ethernet interface unit, meanwhile collect their performances and alarms information Monitor the power module and fan module intelligently and detect alarms reported by the fan board and power module, such as board on-position information, DC power indication, power module type and power module failure information, Support online download and upgrade of board software, Provide four external alarm input interfaces (on-off signal inputs), Provide alarm output interfaces to column-head cabinet (on-off signal outputs), Provide real-time clock, which can be ensured even the power is down due to its built-in battery, Provide a buzzer and ring trip for audible alarm function.

Cross-Connect Unit
Service bus

Service cross-connection

...

Service bus HW bus

Implements cross-connection and protection switching for line signals and tributary signals Support space division cross-connect capacity up to 6464 VC-4 and time division cross-connect capacity up to 20372037 VC-12. Support overhead cross-connection. In the EMS, up to 20 overhead bytes of each optical interface can be configured as full byte-based cross-connection. Support the broadcast, uni-direction and bi-direction working modes through configuration in the EMS.

...

Overhead cross connection

Optical Interface Unit

Adopt LC/PC fiber optic connectors and SFP lasers Provide up to four STM-1/STM-4 compatible optical interfaces, Support VC-4-4C concatenation of STM-4 optical interfaces. Support the function of DCC extraction and insertion. The extraction mode of each DCC can be configured as DCCr (D1-D3), DCCm (D4-D12), DCCr+m (D1-D12) or disabled according to the EMS command. The DCC extraction mode of optical receiving interfaces and optical transmitting interfaces can be configured independently. Support SOH extraction and insertion functions ,and the transparent transportation of overheads Support channel-level loopback. Optical interfaces support line side AU loopback and terminal side AU loopback. Read signal degrade (SD) and signal failure (SF) alarms via board software after the alarm ledout by the hardware connection lines, which ensures protection switching implemented in the specified time.

E1/T1 Tributary Unit

Implement the mapping or demapping of E1/T1 signals., Add/drop the dependent timeslots according to the different timeslot No, and analyze the performance and alarm of E1/T1 signals and report them to the EMS. Support up to 21 channels of E1 or T1 interfaces, both non-balanced and balanced E1 interfaces and only balanced T1 interfaces. Support framing of E1/T1 signals. Support the retiming function at the E1 tributaries. Transmit the DCC bytes transparently through the first three timeslots of the 5th to 8th E1 tributaries Extract the timing clock from the clock recovered from the 1st and 2nd E1 tributaries and send it to the clock unit. Detect the pseudo-random binary sequence at all E1/T1 tributaries.

E3/T3 Tributary Unit

Implements the mapping/demapping of E3/T3 signals. Each board provides three E3/T3 interfaces, which support HDB3 and B3ZS coding/decoding. Process lower-order overheads and pointers, and report corresponding alarms and performance to the EMS.

Ethernet Interface Unit

Processes up to eight channels of Fast Ethernet (FE) services. The main board provides four FE interfaces while the TFEx4/TFEx4B board offers the other four FE interfaces. Supports Ethernet flow control and 802.3x flow control frame processingGFP or PPP/HDLC encapsulation Supports Jumbo frame with 9600 bytes, VLAN processing. Provides eight system side directions and supports service convergence based on port, The system side bandwidth is 10 VC-3 Provides loopback test for engineering applications, and Supports alarm and performance query for user ports and virtual concatenation groups

Overhead Unit

Extracts and combines serial overheads from different directions, and controls the cross-connection, read/write of them Provides user with a transparent channel by using one of the seven bytes (including F1 byte) in the section overheads, and provides an RS232 interface (RJ45 socket) on the front panel of main board.

Overheads extracted from STM-1/STM-4 interfaces are converted to a standard highway (HW) and then sent to the overhead unit. At the same time, the HWs from interfaces on boards in extended slots are sent to the overhead unit too. The overhead unit cross-connects all the overheads. The overhead unit also processes F1 byte in section overheads or configures the other six idle overhead bytes, converts them into RS232 data and then sends the data to corresponding interface circuit.

ECC-2M and HDLC Units

The ECC-2M unit implements the transmission of SDH management information through the 5th-8th 2 M channels. Thus the network management information can pass through equipment developed by other manufacturers.

In the direction from 2 M to ECC, the unit extracts DCC bytes in the 1st-3rd timeslots of the 2 M signal, implements framing and then forwards them to the HDLC bus. In the direction from ECC to 2 M, the unit extracts ECC information from the HDLC bus, unframes it and converts it to DCC bytes. Then it inserts the DCC bytes into the 1st-3rd timeslots of the 2 M signal.

The HDLC unit transmits ECC information received from multiple directions

This unit combines ECC information from multiple directions to the HDLC bus or extracts ECC information from the HDLC bus. Then the HDLC unit forwards the ECC information directly through hardware.

Clock Unit

The clock unit selects the timing reference for the NE from the line clock, tributary clock and external reference clock according to alarm information of clock source and synchronization information The clock unit supports extracted line clock in all optical directions and the tributary clock extracted from the first or the second E1 tributary provides BITS interfaces to implement an external clock output (2.048 Mbit/s or 2.048 MHz) and an external clock input (2.048 Mbit/s or 2.048 MHz). The clock unit has four working mode during the synchronization and phase locking : Fast pull-in mode , Tracking mode , Hold-on mode, and Free-run mode

Micro Control Unit

The micro control unit implements the initialization and configuration of main service chips on the main board and monitors their alarms and performances.

Monitors alarm and performance of each channel and implements protection switching if necessary Initializes and configures chips for PDH, SDH and Ethernet services Controls other modules and allows the interactive processing among these modules Receives commands from the NCP and reports alarms and performances

Main Board

No.

List Of SMC Main Boards


Board Code

Available Interfaces
Optical Interface
2 optical interfaces 2 optical interfaces 4 optical interfaces 4 optical interfaces 2 optical interfaces 2 optical interfaces 4 optical interfaces 4 optical interfaces 2 optical interfaces 2 optical interfaces 4 optical interfaces 4 optical interfaces

Electrical Interface
Eight 75 non-balanced E1 electrical interfaces Twenty-one 75 non-balanced E1 electrical interfaces Eight 75 non-balanced E1 electrical interfaces Twenty-one 75 non-balanced E1 electrical interfaces Eight 120 balanced E1 electrical interfaces Twenty-one 120 balanced E1 electrical interfaces Eight 120 balanced E1 electrical interfaces Twenty-one 120 balanced E1 electrical interfaces Eight 100 balanced T1 electrical interfaces Twenty-one 100 balanced T1 electrical interfaces Eight 100 balanced T1 electrical interfaces Twenty-one 100 balanced T1 electrical interfaces

Other Interface
Each type of SMC main board can provide: 1. One 75 BITS interface, 2. One alarm output interface, 3. One RS232 interface/120 BITS interface, 4. One LCT interface, 5. One network management interface, 6. One alarm input interface, 7.Four fast Ethernet electrical interfaces.

1 2 3 4 5 6 7 8 9 10 11 12

SMCxD75E SMCxD75T SMCxF75E SMCxF75T SMCxD120E SMCxD120T SMCxF120E SMCxF120T SMCxD100E SMCxD100T SMCxF100E SMCxF100T

remark: 1. ZXMP S200 can support the STM-1 electrical service by being configured with the SFP electrical interface module on the SMC board. 2For the main board providing two optical interfaces, each of the optical interfaces supports traffic at the rate of either STM-1 or STM-4. On the board panel, they are identified as 5 and 6.

Main Board

Operating Principle Of SMC Board

Main Board

No.

Operating Principle Of SMC Board


Board Code
SMBxD75E0 SMBxD75T0 SMBxF75E0 SMBxF75T0 SMBxD120E0 SMBxD120T0 SMBxF120E0 SMBxF120T0 SMBxD100E0 SMBxD100F0 SMBxF100E0 SMBxF100F0

Available Interfaces Optical Interface


Two optical interfaces Two optical interfaces Four optical interfaces Four optical interfaces Two optical interfaces Two optical interfaces Four optical interfaces Four optical interfaces Two optical interfaces Four optical interfaces Four optical interfaces Four optical interfaces

Electrical Interface
Eight 75 non-balanced E1 electrical interfaces Twenty-one 75 non-balanced E1 electrical interfaces Eight 75 non-balanced E1 electrical interfaces Twenty-one 75 non-balanced E1 electrical interfaces Eight 120 balanced E1 electrical interfaces Twenty-one 120 balanced E1 electrical interfaces Eight 120 balanced E1 electrical interfaces Twenty-one 120 balanced E1 electrical interfaces Eight 100 balanced T1 electrical interfaces Twenty-one 100 balanced T1 electrical interfaces Eight 100 balanced T1 electrical interfaces Twenty-one 100 balanced T1 electrical interfaces

Other Interface
Each type of SMB main board can provide: 1. One 75 BITS interface 2. One alarm output interface 3. One RS232 interface/120 BITS interface 4. One LCT interface 5. One network management interface 6.One alarm input interface 7.Four fast Ethernet electrical interfaces

1 2 3 4 5 6 7 8 9 10 11 12

Note: For the main board providing two optical interfaces, each of the optical interfaces supports traffic at the rate of either STM-1 or STM-4. On the board panel, they are identified as 5 and 6.

Main Board

Operating Principle Of SMB Board

Main Board

Differences Between SMB Board And SMC Board


Function. SMC Main Board Type SMB Higher-order cross-connect: 3232 VC4 Lower-order cross-connect: 10081008 VC12 Accesses two channels of STM-1 optical signals and two STM-1/STM-4 optical signals Does not support STM-1 electrical interface Supports SNC-N and SNC-I switching at higherorder (VC4) path, and SNC-I switching at lowerorder (VC12) path Supports EIE3 board which accesses E3/T3 service Supports configuration of 12 TUG3 Supports PRBS self-test function RS232 interface

Cross-connect capacity Optical interface unit STM-1 electrical interface unit Switching mode

Higher-order cross-connect: 6464 VC4 Lower-order cross-connect: 20372037 VC12 Accesses four channels of STM-1/STM-4 optical signals Accesses four channels of STM-1 electrical signals Supports SNC-I+SD and SNC-N switching at both higher-order (VC4) path and lower-order (VC12) path Does not support EIE3 board which accesses E3/T3 service Supports configuration of 12 TUG3 Supports PRBS self-test function Ethernet interface

E3/T3 service configuration EOS service configuration PRBS self-test function LCT management interface

DC Power Module (PWA/PWB)

S200 provides two kinds of DC power modules to meet different power supply environment.

PWA module uses -48 V primary DC power supply. Allowed voltage fluctuation range: -36 V to -72 V PWB module uses +24 V primary DC power supply, Allowed voltage fluctuation range: +18 V to +36 V

The DC power module supplies DC power, i.e. the secondary power supply, to all the other boards in ZXMP S200. The power module provides dual power inputs: path A as the active power supply and path B as the standby power supply (such as storage battery). When the path A fails, the power supply is switched to the path B smoothly. Once the path A recovers, the power supply is switched back to the A path. Above means that the path A and path B are 1:1 backup one another.
1. Handle 2. Rotary switch 3. Power indicator of B path 4. Power indicator of A path 5. DC power socket of A path 6. DC power socket of B path 7. Power switch 8. Working status indicator (RUN, ALM) RUNALM

AC Power Module (PWC)

PWC provides 110 V or 220 V AC primary power supply, the allowed voltage fluctuation range of the primary AC power supply is from 90VAC to 290VAC. If the input voltage is higher than 280VAC, the PWC module will start the power supply protection. Once the power supply protection is started, the equipment can not be turned on. Additional voltage-regulated power supply (such as UPS) should be configured when the PWC module is used in ZXMP S200, Besides, Class-B lightning protector with the nominal discharge current of 60 kA should be installed in the equipment room where ZXMP S200 is located.
1. Handle 2. Rotary switch 3. AC power socket 4. Power switch 5. Working status and alarm indicator RUNALM

V.35 Data Interface Board (V35B)


V35B board provides two V.35 synchronous data interfaces of N 64K (N=1-31), which can be connected to V.35 data interfaces of a router directly. It uses E1 timeslots in SDH networks to transfer low-rate transparent data services It converts the high-rate signal received from the backplane into low-rate service signals, and then demaps them to two channels of 2 M signals in the Mapping/Demapping Unit. After that, adapts the 2 M signals to N64K data service signals, which are sent to the Interface Unit. Finally, the Interface Unit converts the N64K signals into V.35 data and output it. In the opposite direction, the V35B board adapts two N64K data signals into 2 M signals and then maps them to 2 M timeslots. The Rate Adaptation Unit converts the signals into high-rate signals and then sent them to the backplane.

The board software and FPGA program can be upgraded remotely online.
1. Captive fastener 2. Ejector lever 3. V.35 interface 1 (PORT1) 4. V.35 interface 2 (PORT2) 5. Working status indicator RUNALM

E1/T1 Electrical Tributary Board

As an extension board of the main board, the E1/T1 electrical tributary board can process 21 channels of E1 or T1 signals. In terms of function, class the electrical tributary board into three types

E1 electrical tributary board with interface impedance 75 E1 electrical tributary board with interface impedance 120 T1 electrical tributary board with interface impedance 100

support HDB3 or B8ZS encoding/decoding. Supports the mapping/demapping and multiplexing/demultiplexing between 21 E1/T1 signals and any timeslots in AU-4. Supports the adding/dropping of timeslots with different serial numbers, and supports independent adding/dropping of timeslots. Supports remote online upgrade of board software and logic programs

1. Captive fastener 2. Ejector lever 3. E1/T1 electrical interface

(channel 1-12) 4. Running indicator (RUN) 5. E1/T1 electrical interface (channel 13-21)

E3/T3 Electrical Interface Board (EIE3)


Provides three E3 or T3 physical interfaces, which support HDB3 or B3ZS code/decode The rate of each interface can be configured as 45 M (T3) or 34 M (E3) through the EMS. Supports the remote online download of board software and logic programs Supports channel protection At the receiving side, the EIE3 board receives three E3/T3 PDH signals. After impedance matching and analog/digital conversion, the EIE3 board sends the digital E3/T3 signals to the main board for mapping and cross-connection. At the transmitting side, the EIE3 board receives three E3/T3 digital signals from the main board. After the digital/analog conversion and impedance matching, it sends the analog signals out from the board.
1. Captive fastener 2. Ejector lever 3. Electrical receive and

transmit interface 4. Running and alarm indicator


RUNALM

4-Channel Transparent-Transmission Fast Ethernet Electrical Interface Board (TFEx4)


Provides four 10 M/100 M adaptive Ethernet electrical interfaces Supports auto-negotiation and forced working status, Supports 10 M/100 M, full duplex modes, Supports AutoMDIX (Auto-Medium Dependent Interface Crossover) function of network cables, i.e. autoidentification of crossover and straight-through network cables. At the receiving side, the TFEx4 board receives four Ethernet signals. After pulse transform, then sends the signals to the main board through the backplane for Ethernet service processing. At the transmitting end, the TFEx4 board receives Ethernet data frames from the main board. After pulse transform, the signals are output from the TFEx4 board.
1. Captive fastener 2. Ejector lever 3. LINK/ACK indicator 4. Ethernet electrical

interface 5. Interface speed indicator

4-Channel Transparent-transmission Fast Ethernet Optical Interface Board (TFEx4B)

provides four Ethernet optical interfaces. supports hot-swappable SFP (small form-factor pluggable) optical modules. The interfaces on the board support optical modules for the transmission distance 2 km (multi-mode 1310 nm) and 15 km (single-mode 1310 nm). At the receiving side, the TFEx4B board receives four Ethernet optical signals. It converts these optical signals into electrical signals and then sends them to the main board (SMC) through the backplane for Ethernet service processing. At the transmitting side, the TFEx4B board receives four Ethernet electrical signals returned by the main board through the backplane. It converts these electrical signals into optical signals and then sends them out from the board.
1. Captive fastener 2. Ejector lever 3. Ethernet optical interface 4. Indicator of Ethernet optical

interface (LA)

Enhanced Smart Ethernet Board (SEC)


Provides 4 FE electrical interfaces at the user side. All of these interfaces meet the requirements of IEEE 802.3, and support the rate of 10 M/100 M, full duplex/half duplex modes as well as self-negotiation and forced working status. Provides 4 system ports at the system side. All of these ports support the convergence in 4:1 mode. Supports the Ethernet flow control and the processing of flow control frames as specified in IEEE 802.3x. Supports Jumbo frames with the length of 9600 bytes. Supports VLAN processing and Q in Q. Supports learning and searching in Independent VLAN Learning (IVL) and Shared VLAN Learning (SVL) modes. The capacity of MAC address table is 8 K. Supports the special processing of L2 frames specified by users. Supports Internet Group Management Protocol Snooping (IGMP) protocol. Provides the Trunk function for ports and supports the protection based on Link Aggregation Control Protocol (LACP). Provides the mirroring function for ports. Supports Multi-Service Transport Platform (MSTP) protocol. User ports support the access mode, TLS (Transparent LAN Services) mode, trunk mode and the transparent transmission mode. The function of querying user ports alarm and performance messages is also provided. At the receiving side, the SEC board accesses 4 channels of Ethernet signal. After L2 switching, these signals are converted into differential signals and then forwarded to the main board through the backplane for Ethernet service signal processing. At the transmitting side, cross-connect, de-map and de-capsulate the Ethernet service signals in the main board firstly. Then send these signals to the SEC board through the backplane. The SEC board performs L2 switching for these signals and finally outputs them. 1. Captive fastener 2. Ejector lever 3. LINK/ACK indicator 4. Ethernet electrical interface 5. Interface speed indicator 6. Running and Alarm indicator RUNALM

SHDSL Interface Board (SDB)

G.SHDSL (Single-pair high-bit-rate Digital Subscriber Line) is a telecommunication technology corresponding to ADSL and VDSL. It not only supports the symmetrical data rates of 2.048 Mbit/s but also has the longer transmission distance than ADSL. Replacing E1 lines by G.SHDSL can access the high-speed data services for transmission over long distance. Provides up to 4 SHDSL data interfaces that meet the requirements of ITU-T G.991.2; supports two lines mode and symmetric PSD (Power Spectral Density). Supports the rate symmetry for the upward and downward data of each SHDSL. Supports the framing of E1 signals. Supports retiming four E1 signals, which is set on the EMS. Supports the remote download of board software Provides two loopback configuration points at VC12 and SHDSL ports for convenient test. Each loopback point supports two loopback modes: terminal-side loopback and line-side loopback. It is hot pluggable.
1. Captive fastener 2. Ejector lever 3. Interface alarm indicator 4. SHDSL interface 5. Line connection indicator 6. Running and alarm indicator RUNALM

Audio Interface Board (AI)

The AI board provides analog audio interfaces without feed, Each board provides six audio interfaces of two-line or four-line type, which are optional, The electrical level of interface: transmitting end: 0 Db, receiving end: 0 dB, 3.5 dB or -7 dB, optional The AI board uses idle overhead bytes in SDH frames to carry transparent analog services.

1. Captive fastener 2. Ejector lever 3. Audio interface 4. Running and alarm indicatorRUNALM

Orderwire Board (OW)

The OW board supports orderwire telephone and low-speed data transmission. In addition, it supports the trunk (TRK) function, implementing the orderwire communication between two SDH NEs without optical connection, between SDH NE orderwire and the Public Switched Telephone Network (PSTN). One orderwire telephone interface and six channels of RS232/RS485 interface (or three channels of RS422 interface) are available on the OW board. The OW board uses E1, E2, protection bytes and other idle overhead bytes to carry orderwire data and low-speed data

1. Captive fastener 2. Ejector lever 3. RS232/RS485/RS422

interface

4. TRK interface (TRK) 5. Orderwire telephone interface (PHONE) 6. Running and alarm indicator RUNALM