Vous êtes sur la page 1sur 18

Scanning Probe Microscopy

(SPM)
Real-Space
Surface Microscopic Methods
SPM Principle
Probes that are nanosized (accomplished
microlithographically),
scanning and feedback mechanisms
that are accurate to the subnanometer
level (achieved with piezoelectric
material), and
highly sophisticated computer controls
(obtained with fast DACs (digital analog
converters, etc.).
Consists of
Schematic of SPM Principle
Resolution Comparison
3 Axis Cylindrical Piezo
SPM Tree
Conventional STM
Topography of conductive surfaces, I-V spectroscopy (e.g., local band gaps)
Ballistic Electron Emission Microscopy and Spectroscopy
Subsurface investigations, e.g., of metal/semiconductor interfaces
STM Scanning Tunneling Potentiometry
Scanning Tunneling Microscopy Surface potential studies (e.g., study of grain boundaries)
Photovoltaic and Photoassisted Tunneling Spectroscopy
Surface electron-hole pair recombination during photo-excitation
Inelastic Electron Tunneling
STM induced photon emissions (study of heterostructures)
Conventional SFM (atomic force microscopy AFM)
Topography of mainly non-conducting surfaces, force spectroscopy
(S)LFM (Lateral force mapping of surfaces)
SFM Friction studies, local material distinction ("Chem. Force Microscopy" )
Scanning Force Microscopy (S)EFM (Electrostatic Force Microscopy)
Non-contact electrostatic force mapping, (e.g., study of charge decay)
SPM (S)MFM (Magnetic Force Microscopy)
Scanning Probe Microscopy Contact and non-contact technique used to study magnetic domains
Rheological Force Microscopy
Contact sinusoidal modulation (distance or force) methods
(S)UFM (Ultrasonic Force Microscopy)
non-linear surface effects (e.g., true non-contact interactions, or rheology)
(S)PFM (Pulsed Force Microscopy); rheology and adhesion force mapping
SCAM (Scanning Capacitance Microscopy); measuring of trapped charges
SECM (Scanning Electrochemical Microscopy); spatial variations of Faradaic currents or potential changes)
SNOM (Scanning Near-field Optical Microscopy); optical properties, luminescence
SMM (Scanning Micropipette Microscopy); local ion concentration (e.g., transport processes in membranes)
SCM (Scanning Calorimetric Microscopy); local heat transfer coefficients and transition temperatures
SNOM (Scanning Nearfield Optical Microscopy)
SNAM (Scanning Near-field Acoustic Microscopy); topography and rheology
The Three Basic SPM Systems
Scanning Tunneling Microscope (STM)

Scanning Force Microscope (SFM)
Scanning Nearfield
Optical Microscope (SNOM)
Scanning Tunneling Microscopy (STM)
Signal: Tunnel Current
The tunnel current depends
on the tip-sample distance,
the barrier height, and the
bias voltage. Studying the
bias dependence provides
important spectroscopic
information on the occupied
and unoccupied electronic
states (-> local LDOS
studies).
u
T

u
S

u
S

u
T

Positive sample bias: Net tunneling
current arises from electrons that tunnel from
occupied states of the tip into unoccupied
states of the sample
Negative sample bias: Net tunneling
current arises from electrons that tunnel from
occupied states of the sample into unoccupied
states of the tip.
The tunnel current is strongly distance, Dz, dependent
( ) z A exp V I
2 / 1
bias
A u
A = const.
Conventional STM
Tunneling Current, I
Bias Voltage, V
Conductive Sample
STM Tip
Piezo Scanner
STM Modes of Operations
Examples:
Constant height imaging or variable current mode (fast scan mode)
The scan frequency is fast compared to the feedback response, which
keeps the tip in an average (constant) distance from the sample surface.
Scanning is possible in real-time video rates that allow, for instance, the
study of surface diffusion processes.
Differential tunneling microscopy
Tip is vibrated parallel to the surface, and the modulated current signal is
recorded with lock-in technology.
Tracking tunneling microscopy
Scanning direction is guided by modulated current signal (e.g., steepest
slope).
Scanning noise microscopy
Use current noise as feedback signal at zero bias.
Nonlinear alternating-current tunneling microscopy
Conventionally, STM is restricted to non-conducting surfaces. A high
frequency AC driving force causes a small number of electrons to tunnel
onto and off the surface that can be measured during alternative half-cycles
(third harmonics).
Scanning Force Microscopy (SFM)
Sample
SFM Tip
Piezo Scanner
z
Force: F
N
= k
N
*Az

Ppring constant: k
N
Spring deflection: Az

Interaction or force
dampening field
Contact Method: Non-Contact Method:
Sample
Input Modulation Cantilever Response
Scan
Cantilever
4-Quadrant
Photodiode
Laser
fully elastic viscoelastic
Ao = 0 Ao > 0
e o
e Ao
e o
F
riction
Topography
50/50 PS/PMMA blend annealed at 180
o
C for 1 week
Spinodal Decomposition of PS/PMMA Blend
PS
PMMA
PMMA
PS
10 m
complex flow pattern over time
SFM Topography SFM Lateral Force
2D spinodal decomposition
different from bulk
Note: The bright spots (PS phase/lateral force image) represent
spinodal frustration points of PMMA.
50/50 PS/PMMA blend annealed at 180
o
C for 1 week
Spinodal Decomposition of PS/PMMA Blend
PS
PMMA
PMMA
PS
10 m
PS
PMMA
PMMA
PS
10 m 10 m
complex flow pattern over time
SFM Topography SFM Lateral Force SFM Topography SFM Lateral Force
2D spinodal decomposition
different from bulk
Note: The bright spots (PS phase/lateral force image) represent
spinodal frustration points of PMMA.


Rheological SFM
Sample
SFM Tip
Piezo sinusoidally
modulated either in x or z
z
Load:
F
N
= k
N
*Az


Lateral Force:
F
L
= k
L
*Ax


x
Input Modulation Signal
Response Modulation
Signal
Amplitude
Time
Time Delay
Topography Modes of SPM

Constant deflection (contact mode)
Analog to the constant current STM mode. The deflection of the cantilever
probe is used as the feedback signal and kept constant.
Constant dampening (AM detection, intermittent contact mode in air or
liquid)
The response amplitude of sinusoidally modulated cantilevers allow
feedback in the pseudo-non-contact regime (intermittent contact) due to
fluid dampening.
Constant frequency shift (FM detection, non-contact mode in ultrahigh
vacuum)
Similar to the FM radio, the frequency is measured and frequency shifts are
used as feedback system. This approach works only in vacuum where fluid-
dampening effects can be neglected.
Variable deflection imaging (contact mode)
Analog to the variable current STM (constant height) mode. Uses fast scan
rates compared to the force deflection feedback (close to zero). Sensitive to
local force gradients such as line defects. Improved high resolution
capability (atomic resolution).
SFM Force Spectroscopy
Sample
F(D) forces acting on the tip
linearly ramped voltage
applied to piezo
D = D
o
- vt
F(D)
0
D
jump in contact
jump out of contact
Cantilevers Probes for SFM
Scanning Near-field Optical
Microscopy (SNOM)
SNOM Principle (Pohl et al. 1984): A tiny
aperture, illuminated by a laser beam from the
rear side, is scanned across a samle surface,
and the intensity of the light transmitted through
the sample is recorded. To achieve high lateral
resolution (first experiments provided already
tens of nanometer resolution), the aperture had
to be nanometer sized, and maintained at a
scanning distance of less than 10 nm from the
sample surface (i.e., within the evanescent field).
SNOM Schematic Examples
Small aperture
Evanescent Field
Regime
Illumination
Objective
Detector

Sample
Illumination
Objective
Detector

Sample
Illumination Mode Reflection Mode
SNOM

Vous aimerez peut-être aussi