Vous êtes sur la page 1sur 28

1.

Production Capacity
1) Annual Production Capacity 2) Maximum Capacity 3) Maximum Voltage 4) Factory Space : 28,000MVA : up to 800MVA(3 phase) : up to 765kV, 2050 BIL : 16,800m

HYUNDAI

5) Manpower for Transformer factory - 55 Engineers - 340 Skilled Workers

2. Production Range
1) Power Transformer

HYUNDAI

2) Distribution Transformer
3) Cast resin Transformer 4) Special Purpose Transformer

Rectifier Transformer Furnace Transformer Dry type Transformer Shunt Reactor Mobile Transformer

3. Quality Assurance (ISO 9001)


1) Original Date of Issue : July of 1989 2) Registered Parts of Quality Assurance

HYUNDAI

Transformer Design and Development


Production and Testing Installation and Service

4. Applicable Standard
1) IEC 76 2) ANSI C57.12.00 3) CAN/CSA-C88-M90 4) AS 2374 5) ES 140 (For Europe and Asia) (For America) (For Canada) (For Australia) (For Korea)

HYUNDAI

5. Short Circuit Test


1) Major Performance Record of Short Circuit Test
No. 1 Specification of Transformer Generating Transformer 3PH 6/64/85/106/119MVA 230/14.8kV YNd1 Test Date Test of Tap Change N.L.T.C

HYUNDAI

Customer

Sept. 1995

PUD in USA

Power Transformer 3PH 45/60MVA 154/23kV Ynyno(d)

Nov. 1989

O.L.T.C

KEPCO in Korea

Power Transformer 3PH 35/44MVA 154/23kV YNd1

Nov. 1986

O.L.T.C

In-Chon Iron & Steel in Korea

Distribution Transformer 3PH 10MVA 22/6.6kV Ynynod(d)

Dec. 1986

O.L.T.C

PUB in Singapore

Power Transformer 3PH 20/26MVA 132/11.5kV Dyn11

Dec. 1986

O.L.T.C

WAPDA in Parkistan

5. Short Circuit Test

HYUNDAI

2) Detailed Explanation for the Short Circuit Test Performed to the 230kV Transformers for Rocky Reach Project

Customer : Public Utility District No.1 of Chelan County in U.S.A Project : Replacement for Rocky Reach Dam Transformer

Transformer Rating

3phase 60Hz 119MVA 14.8/230kV Step-up Transformer

Basic Impulse Level on H.V Side : 900kV


Standard : ANSI C57.12.00

Tested and Certified by Korea Electrotechnology Research Institute

Picture of Short Circuit Test


HYUNDAI

6. Development of Transformer
1) 765kV Transformer

HYUNDAI

1PH 60Hz 2 x 333.3MVA 765/345kV


OLTC type Auto transformer (Bil : 2050kV) : 1998 Developed

1PH 60Hz 204MVA 20.9/765kV NLTC type Step-up transformer (Bil : 2050kV) : 1999 Developed

1PH 60Hz 370MVA 765/345/23kV NLTC type Auto transformer (Bil : 2050kV) : 1999 Developed

2) Gas Insulated Transformer

1PH 60Hz 20MVA 154/23kV OLTC Type Transformer (Under Development)

6. Development of Transformer
3) Mobile Transformer (Developed)

HYUNDAI

3PH 60Hz 40MVA 154/23kV (1996) "H" Class insulation (95C temp. rise) Comparison of "A" and "H" class insulation
Insulation
A Class H class
Remark

No Load Loss
31 kW 23 kW 74%

Load Loss
241 kW 434kW 180%

Weight
35 TON 25 TON 71%

Transportation with trailer


Weight : 39.4 Ton Size(m) : L8.6 x W2.9 x H3.9


10

Picture of 154kV 40MVA Mobile Transformer-Using H Class Insulation (NOMAX Paper)

HYUNDAI

11

7. Major International Clients and Performances


1) North America
Country Client
Alumnium Company of America Los Angeles Department of Water and Power Chelan Country Black & Veatch General Electric Company Baltimore Gas & Electric CRS Sirrine Engineers Zurn Nepco Westinghouse Florida Power Corporation Colorado River Commission of Nevada Sacramento Municipal Utility District Duke Fluor Daniel Babcock & Wilcox Engineering Lower Colorado River Authority Puget Sound Energy National Electrical System Inc. City of Tacoma New York Power Authority

HYUNDAI

Rating of Transformer
161/13.8kV, 93MVA 34.5/5.04kV, 16MVA 230/14.8kV, 119MVA 230/15.75kV, 315MVA 138/13.8kV, 125MVA 13.8/2 X 3.9kV, 20MVA 69/13.8KkV, 90MVA 132/11.5kV, 90MVA 138/13.8kV, 150MVA 16/230kV, 235MVA 230/69kV, 200MVA 230/69/13.8kV, 200MVA 115/11kV, 93MVA 138/15.5kV, 160MVA 138/22.8kV, 490MVA 230/117.8kV, 325MVA 115/13.2kV, 115MVA 115/13.8kV, 56MVA 230/13.2kV, 86MVA
12

U.S.A

7. Major International Clients and Performances


2) South America
Country Client
Interconexion Electrical S.A

HYUNDAI

Rating of Transformer
230/34.5kV, 50MVA 500/230/34.5kV, 150MVA

Colombia
EPM ESSA 230/115/46kV, 90MVA 115/34.5/13.8kV, 40MVA 33/12kV, 6MVA 115/13.8kV, 50MVA 230/110/13.2kV, 130MVA 220/60/10kV, 50MVA 230/13.8kV, 150MVA 200/115/13.8kV, 200MVA 115/2 X 13.8kV, 300MVA 138/13.8kV, 33.3MVA

Trinidad & Tobago Panama Chile Peru Guatemala Venezuela

Trinidad & Tobogo Electricity Commission (TTEC) CELMEC Chilectra Proyecto Ampliacion de LA S. E. JBV Guatemala, LCC ENELVEN Abengoa CERJ

Puerto Rico Brazil

13

7. Major International Clients and Performances


3) Asia
Country
Japan

HYUNDAI

Client
Tokyo Electric Power Company Public Utilities Board (PUB) Tenaga Nasional Bhd. (TNB)

Rating of Transformer
66/6.9kV, 20MVA 22/6.6kV, 10MVA 275/132kV, 240MVA 275/230kV, 250MVA 275/132kV, 180MVA 150/20kV, 100MVA 230/115/13.8kV, 300MVA 110/34.5/13.8kV, 83.3MVA 230/121/22kV, 63MVA 110/6.6kV, 20MVA 240/140kV, 150MVA

Singapore
Malaysia

Sarawak Electricity Supply Corp. (SESCO) Sabah Electricity Board (SEB)

Indonesia Philippines

Perusahaan Umum Listrik Negara (PLN) National Power Corp (NPC) Manila Electric Company (MERALCO)

Vietnam

Electricity of Vietnam (EVN) Vietnam POSCO Steel Co.

Bangladesh

Bangladesh Power Development Board (BPDB)

14

7. Major International Clients and Performances


3) Asia
Country Client
Electricity Generating Authority of Thailand (EGAT)

HYUNDAI

Rating of Transformer
115/34.5/11kV, 50MVA 60/11.5kV, 60MVA 115/23.1kV, 40MVA 132/33/11kV, 30MVA 230/11kV, 125MVA 132/11kV, 40MVA 132/6.3kV, 20/26MVA 6.6/0.433kV 2000KVA (Cast Resin Type)

Thailand
Metropolitan Electricity Authority (MEA) Provincial Electricity Authority (PEA)

Myanmar

Myanmar Electric Power Enterprise (MEPE) Water and Power Development Authority (WAPDA)

Parkistan
Karachi Electricity Supply Corporation (KESC) D. G Khan Cement Company

India

Oil and Natural Gas Commission (ONGC)

Srilanka

Ceylon Electricity Board (CEB)

132/33kV, 31.5MVA

15

7. Major International Clients and Performances


4) Middle East
Country
Electricity Corporation SCECO-Central

HYUNDAI

Client

Rating of Transformer
132/33kV, 60MVA 132/13.8kV, 100MVA 230/115/34.5kV, 400MVA 132/13.8kV, 100MVA 66/13.8kV, 67MVA 400/138.6/11kV, 250MVA 132/33kV, 25MVA 66/20-11kV, 40MVA 33/11kV, 15MVA 11/0.433kV, 1500KVA (Cast Resin Type) 33/11kV, 20MVA Shunt Reactor 154kV, 5MVAR
16

Saudi Arabia
SCECO-East Tabouk Electricity Company Arabian American Oil Company

Iraq Yemen Lebanon U.A.E

State Organization of Electricity (SOE) Yemen General Electricity Corp. (YGEC) Council for Development & Reconstruction Dubai Electricity Company

Water and Electricity Department

Oman Turkey

Ministry of Electricity and Water Turkiye Electric Kurumu

7. Major International Clients and Performances


5) Oceania and Canada
Country
Australia

HYUNDAI

Client
Pacific Power (The Electricity Commission of New Sourth Wales) Power Link (Queensland Electricity Commission) BHP Engineering Pty Ltd. Shortland County Council New Zealand Aluminium Smelter Ltd. (NZAS) The Electricity Commission of P.N.G British Columbia Hydro & Power Authority Richmond Hill Hydro Manitoba Hydro Alberta Power Ltd.

Rating of Transformer
132/11kV, 20MVA 132/69/11kV, 20MVA 230/34.5kV, 80/120MVA 132/66/11kV, 120MVA 66/13.8kV, 67MVA 220/11kV, 50MVA 132/66kV, 20MVA 512.5/242/25.2kV, 500MVA 212.5/2 X 28kV, 125MVA 114.3/2 X 12.47kV, 50MVA 144/25kV, 50MVA

New Zealand Papua New Guniea

Canada

Howe Sound Pulp & Paper Ltd. Yukon Electrical Company Stone & Webster Canada Ltd. Transalta Vtilities Agra Monenco/ Aurora Mine Saskatchewan Power Corporation

230/13.8kV, 62MVA 138/13.8kV, 40MVA 243/2 X 13.8kV, 171MVA 260/72kV, 224MVA 260/72kV, 116.2MVA 128/24.9kV, 29.8MVA
17

7. Major International Clients and Performances


6) Europe
Country
Switzerland

HYUNDAI

Client
ABB Power Generation Ltd. Siemens AG Johs Gran-Hassen Product Ltd.

Rating of Transformer
220/21kV, 420MVA 132/6.9kV, 40/45MVA 220/60/10kV, 40/50MVA

Germany
Denmark

7) Africa
Country
Egypt

Client
Egyptian Electricity Authority (EEA) Arco Steel

Rating of Transformer
21/220kV, 395MVA 220/22.5kV, 80MVA 132/15kV, 22MVA 11/225kV, 105MVA

Ethiopia Libya

Ethiopian Electric Light and Power Authority (ELPA) Heavy Industries Secretariat Tripoil Socialist Peoples Libyan Arab Jamshebreya

18

8. Major Production Facilities


1) Over-Head Crane (300 TON x Span 38m) 2) Vacuum Vaporization Facility (L 13m x W 4.8m x H 6.6m) 3) Air - Cleaning Facility (L 45m x W 40m x H 7m) 4) Oil Filtering Machine (8,00 litter / hour) 5) Motorized Transporter for Test (400 TON x 2EA) 6) Core Binding Machine (40 TON x W 8m) 7) Core Lamination Table (120TON)

HYUNDAI

19

9. Major Testing Facilities


1) Impulse Generator System ( 400KV / 600KJ )

HYUNDAI

2) Oscillation Lightning Impulse Test System (1,800KV / 90KJ )


3) AC Series Resonant Voltage Test System (1,200KV / 4,800KVA )

4) AC Power Generator System ( 23MVA x 2sets )


5) AC Power Generator System ( 23MVA x 2sets ) 6) Condenser Bank ( 158KV, 225MVAR ) 7) Transformer Loss Measuring System (200KV / 4,000A )

20

10. Major Manufacturing Process


1) Winding Works

HYUNDAI

21

10. Major Manufacturing Process


2) Core lamination

HYUNDAI

22

10. Major Manufacturing Process


3) View of Core Structure (After Completion of Core Lamination)

HYUNDAI

23

10. Major Manufacturing Process


4) Coil Insertion Works

HYUNDAI

24

10. Major Manufacturing Process


5) View of Core and Coil Assembly Works

HYUNDAI

25

10. Major Manufacturing Process


6) Drying Works in Vacuum Vaporization Facility

HYUNDAI

26

10. Major Manufacturing Process


7) Completion of Core & Coil Assembly

HYUNDAI

27

10. Major Manufacturing Process


8) Factory Test

HYUNDAI

28

Vous aimerez peut-être aussi