OWG001206 MSOFTX3000 Signaling Data Configuration

ISSUE 1.0

Wireless Curriculum Development Section

Course Objectives

Upon completion of this course, the trainees should be able to: Master the signaling link and GT configuration Understand signaling table relation

2
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

References

MSOFTX3000 Operation Manual-Data Configuration

3
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

Course Contents

Chapter 1 Basic concepts Chapter 2 MTP Data Configuration Chapter 3 SCCP Data Configuration Chapter 4 Examples

4
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

Hierarchy of SS7 protocol

MAP

CAP

BSSAP+
TCAP

SCCP MTP

TCAP: Transaction Capabilities Application Part SCCP: signaling connection control part MTP: message transfer part
5
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

Basic Concepts of No.7 Signaling System

Signaling Link

Signaling Link set SLC


SLS

Signaling Route

6
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

Basic Concepts of No.7 Signaling System

7
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

Basic Concepts of No.7 Signaling System

Signaling link:

one of the elements of the signaling

network, which are the physical links


connecting all the signaling points and signaling transfer points, and over which

the signaling messages are transmitted.

8
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

Basic Concepts of No.7 Signaling System

Signaling linkset:

A number of parallel signalling

links that directly interconnect two


signalling points constitute a

Signalling LinkSet.

9
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

Basic Concepts of No.7 Signaling System

SLC: Signaling link code

Each link in one linkset must be numbered uniformly.

We call this number SLC.


SLC must be same between two offices.

10
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

Basic Concepts of No.7 Signaling System

SLS: Signaling link Selection

SLS is used to signaling link/route selection.

In MSOFTX3000/SSP/IP, SLS cooperates with MASK in data configuration, and implement the load sharing between signaling linkset/link.

11
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

Basic Concepts of No.7 Signaling System

Signaling Route:

The path leading from the local

signaling point to the destination


signaling point is called signaling route.

12
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

Course Contents

Chapter 1 Basic concepts Chapter 2 MTP Data Configuration Chapter 3 SCCP Data Configuration Chapter 4 Examples

13
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

Relationship of MTP Configuration table

14
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

MTP Data Configuration

Configuration Procedure

Configure DSP

Configure signaling link set

Configure signaling route

Configure signaling link

End
15
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

MTP Data Configuration

Configuration for new signaling links in existed linkset

Configure signaling link

Modify signaling link set configuration

End

16
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

MTP Data Configuration

Configuration for new DSP using existed linksets

Configure DSP

Configure signaling route

End

17
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

Course Contents

Chapter 1 Basic concepts Chapter 2 MTP Data Configuration Chapter 3 SCCP Data Configuration Chapter 4 Examples

18
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

Procedure for SCCP data configuration


SCCP DSP table (ADD SCCPDPC)


SCCP SSN table (ADD SCCPSSN) GT table (ADD SCCPGT)

19
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

SCCP DSP table

Like the MTP destination signaling point table, only the destination signaling point data which can be seen at the SCCP layer and can transmit the SCCP messages should be set.

20
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

SCCP addressing mode

SPA SubSystem

STP SubSystem

SPB SubSystem

SCCP

SCCP

SCCP

MTP DPC+GT

MTP DPC

MTP

21
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

SCCP SSN table

SCCP SSN table (ADD SCCPSSN)

Local office
MSC,VLR, BSSAP, CAP, and SCMG,RANAP

Other Office
HLR:HLR,SCMG Other MSOFTX3000:MSC,SCMG,VLR,MAP BSC:BSSAP/INAP , SCMG STP: SCMG RNC:RANAP,SCMG

22
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

GT table

In this table,you should configure:


Local

office MSC/VLR No. For location update E.214 code for MS E.164 code for HLR No. For the called MS E.164 code for MS For Short Messages E.164 code for SMC No. For SCP E.164 code for SCP No. which has relationship with the local office
23
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

Course Contents

Chapter 1 Basic concepts Chapter 2 MTP Data Configuration Chapter 3 SCCP Data Configuration Chapter 4 Examples

24
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

Chapter 4 Examples

2.1 HLR 2.2 SMC 2.3 SGSN 2.4 GMLC

25
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

Procedures for configuring data at MSOFTX3000 for interworking with HLR


Procedure 1. Configure MTP 1) Add MTP DSP 2) Add MTP link set 3) Add MTP route 4) Add MTP link 2. Configure SCCP 1) Add SCCP remote signaling point 2) Add SCCP subsystem 3) Add SCCP GT Command

ADD N7DSP ADD N7LKS ADD N7RT ADD N7LNK ADD SCCPDSP ADD SCCPSSN ADD SCCPGT

26
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

GT table
When MSOFTX3000 is directly connected to HLR in signaling, it is required to configure the following GT data for the three cases.

1)IMSI GT and HLR-NUMBER GT for location update 2)Ordinary GT (HLR-MSISDN GT) when the subscriber is called 3)Local MSC GT to be queried when the local office performs second-stage number analysis.

27
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

Chapter 4 Examples

2.1 HLR 2.2 SMC 2.3 SGSN 2.4 GMLC

28
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

Networking and protocols between MSOFTX3000 and SMC

TDM TDM based E MSOFTX3000 MAP TCAP SCCP MTP3 MTP2 MTP1 SMC

29
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

Procedures for configuring data at MSOFTX3000 for interworking with SMC


Procedure 1. Configure MTP 1) Add MTP3 DSP 2) Add MTP3 link set 3) Add MTP3 route 4) Add MTP link 2. Configure SCCP 1) Add SCCP remote signaling point 2) Add SCCP subsystem (SCMG,MSC subsystem) 3) Add SCCP GT 3. Modify MAP configuration parameter table ADD N7DSP ADD N7LKS ADD N7RT ADD N7LNK Command

ADD SCCPDPC ADD SCCPSSN ADD SCCPGT

MOD MAPACCFG

30
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

Parameter relationship between MSOFTX3000 and SCP


SMC parameters MSOFTX3000 parameters ADD N7DSP
[DSP index] Signaling network indicator SMC OPC Peer end MSC DPC [NI ] [DPC] [O PC] [LinkSet Index]

ADD N7LKS
[LinkSet Index] [Adjacent DSP Index]

ADD N7RT
[DSP index] [Priority]

ADD SCCPDSP
[NI] [DPC] [OPC] SLC

ADD N7LNK
[Link No.] No] [Start Circuit No. No ] [LinkSet Index [ ] [Signaling Link Code ]

ADD SCCPSSN
[NI] [SSN] [SPC] [OPC]

ADD SCCPGT
[NI ] SMC NUMBER [GT Address Information] [SPC]

31
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

Chapter 4 Examples

2.1 HLR 2.2 SMC 2.3 SGSN 2.4 GMLC

32
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

Networking and protocols between MSOFTX3000 and SGSN

TDM TDM TDM based Gs MSOFTX3000 BSSAP+ SCCP MTP3 MTP2 MTP1 SGSN

33
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

Data configuration procedures


Procedure Configure MTP 1) Add MTP DSP 2) Add MTP link set 3) Add MTP route 4) Add MTP link Configure SCCP 1) Add SCCP remote signaling point 2) Add SCCP subsystem (Gs, SCMG) 3) Configure SCCP GT Configure SGSN 1) Configure SGSN number 2) Configure Gs interface network indicator 3) Modify MAP configuration parameter table Command

ADD N7DSP ADD N7LKS ADD N7RT ADD N7LNK


ADD SCCPDPC ADD SCCPSSN ADD SCCPGT

ADD SGSNNO MOD MSFP MOD MAPACCFG

34
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

Parameter relationship between MSOFTX3000 and SGSN


SGSN parameters MSOFTX3000 parameters ADD N7DSP
[DSP index] Signaling network indicator SGSN OPC Peer MSC DPC [NI] [DPC] [OPC]

ADD N7LKS
[LinkSet Index] [Adjacent DSP Point Index] Index]

ADD N7RT
[LinkSet Index] [DSP index] [Priority]

ADD SCCPDSP
[NI] [DPC] [OPC] SLC

ADD N7LNK
[Link No. No] [Start Circuit No.] No [[LinkSet Index] [ [Signaling Link Code] Code

ADD SCCPSSN
[NI] [SSN ] [SSN] [SPC [SPC] [OPC]

ADD SCCPGT
[NI] [GT Address Information] [SPC]

ADD SGSNNO
SGSN number [SGSN NUMBER]

35
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

Chapter 4 Examples

2.1 HLR 2.2 SMC 2.3 SGSN 2.4 GMLC

36
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

Networking and protocols between MSOFTX3000 and GMLC


TDM TDM based MAP MSOFTX3000 MAP TCAP SCCP MTP3 MTP2 MTP1 GMLC

37
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

Configuration procedure of interworking between MSOFTX3000 and GMLC


Procedure
Configure MTP 1) Add MTP3 destination signaling point 2) Add MTP3 link set 3) Add MTP3 route 4) Add MTP3 link Configure SCCP 1) Add SCCP remote signaling point 2) Add SCCP subsystem (GMLC, SCMG) 3) Add SCCP GT to GMLC Configure LCS data 1) Configure GMLC number 2) Configure client GMLC information 3) Configure emergency call GMLC number 4) Configure emergency service category information 5) Add called analysis data (optional)

Command
ADD N7DSP ADD N7LKS ADD N7RT ADD N7LNK ADD SCCPDSP ADD SCCPSSN ADD SCCPGT

ADD GMLC ADD GMLCCLT ADD GMLCECL ADD ESRVCAT ADD CNACLD

38
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

Parameter relationship between MSOFTX3000 and GMLC


GMLC parameters MSOFTX3000 parameters ADD N7DSP
[DSP index] Network Indicator GMLC OPC MSC DPC [NI] [DPC] [OPC]

ADD N7LKS
[LinkSet Index] [Adjacent DSP Index]

ADD N7RT
[LinkSet Index] [DSP index] [Priority]

ADD SCCPDSP
[NI] [DPC] [OPC] Singaling Link Code (SLC)

ADD N7LNK
[Link No.] No] [Start Circuit No.] [LinkSet Index] [Signaling Link Code]

ADD SCCPSSN
[NI] [SSN] [SPC] [OPC]

ADD SCCPGT
[NI] [GT Address Information] [SPC]

ADD GMLCCLT
[GMLC CLIENT ID] [GMLC NUMBER]

ADD GMLCECL ADD GMLC


[GCI OR LAI] GMLC No. [GMLC NUMBER] [GMLC NUMBER] [Emergency Call Number]

ADD ESRVCAT
[Emergency Services] [Service Dial Number]

39
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal

Summary

Master data configuration steps

MTP SCCP

Master data configuration method of the following products

HLR
SMC SGSN

GMLC
40

Confidential Information of Huawei. No Spreading without Permission.

Security Level: Internal

41