TYPES OF POLES
6m / 50kg 8.3m / 100kg , 8.3m / 500kg 9m / 115kg 10m / 225kg 11m / 350kg , 11m / 500kg , 11m / 850kg , 11m / 1200kg 13m / 500kg , 13m / 850kg , 13m / 1200kg
The molder. The steel bars. ( brand, the place of piling, galvanized or not..) The method of water treatment. The portion of cement, sand & metal in the mixture, ext.
TESTING OF POLES PART II APPLY LOAD, MEASURE THE DEFLECTION & CRACK POSITIONS
CONTS
CONTS
Steps of applying the load :Consider the ultimate load as 2.5 (safety factor) of the ultimate load. Test load shall be applied & raised in increments of 10% of the ultimate load. Load upto 40% of ultimate load and unload fully. Load upto 60% of ultimate load and unload fully. Load till the pole is broken. Meanwhile measure the deflection (in mm) & check the hair cracks for every loadings. After the loading test finishes, break the pole in 3 places and measure the no. of steel bars, its diameter, spacing between stirrups, etc.
CONTS
IN PRACTICALLY..