Vous êtes sur la page 1sur 24

Prepared By Mohd Haidara Altemimi

Oil was discovered at Bu Hasa in 1962. First well was discovered Bu-12, started in 1962 and by 1965 the field was in production from the Shuaiba Reservoir, followed in 1971 from ThamamaB, and in 1995 from Thamama-F. The oilfield covers an area of approximately 600sq kms, comprising reservoirs formed of shallow-water limestone separated by dense limestone, located at depths between 7500 and 9250ft, known as the Thamama Group.

The oil is produced predominantly by natural flow, currently from 69-single completion, 137 dual completion, 10 oil producer/water injector, and 3 artificial lift wells. The oil flows via single flowlines from each well to one of three Remote Degassing Stations and onward to, or direct to, one of the four Central Degassing Stations . For upto-date well status, refer to the Bu Hasa Monthly Well Status Summary maintained by Production Engineering.

Surface Safety Valve Bottom Hole Test Adapter

Surface Safety Valve


Choke Housing

Choke Housing

Swap Valve
Wing Valve Wing Valve Non Return valve

Master valve

Casing/Tubing

Isolation Valve
CRUDE OIL

Short String

CRUDE Long String OIL

Casing /Casing

Expansion Loop

CRUDE OIL CRUDE OIL

100FT Ball Valve

NRV 6 x 900

Test header
Battery Limit Valve

Production header
Transfer Line

First Stage Separator


PSV

250 Psi GAS OUTLET TO GASCO

By Pass Valve

M1

Gas Drain Oil drain

Bottom Pipe

4 Mist extractor check valve

OIL FLOW

Bettis Valve Level control valve

Secand Stage Separator


PSV

45 Psi GAS OUTLET TO GASCO

M1

Gas Drain Oil drain

Bottom Pipe

4 Mist extractor check valve

OIL FLOW

Level control valve

From Bank-1

From Bank-2

From Bank-3

Oil Flow to Boot


From Bank-4

Gas outlet to Gasco Blower

GAS
Boot pressure 2.77 PSI

BOOT

OIL

FST Pressure 1.5H2O


Pressure Vacuum Valve

Hatch Point Blanket Gas Flapper

Gas to Tank Flare

GAS
Flow Suction Tank

OIL WATER

Drain Line Water To DSDH

Recycle Valve

Suction MOV

Discharge MOV

FST Out let Valve

BOOSTER PUMP

Flow Control Valve

Orifice Meter
Oil Flow To Sulzer

Turbine Meter

Strainer

Flow Control Valve

Flow Control Skid

The Well Head is located on the top of the well casing string.

X MASS TREE is the combination of valves which is located on top of well head.

The Function of X MASS Tree is to open and close the string

also to hold Downhole Equipment / Pressure.

A Large Valve on the Xmas tree used to control the flow of oil

and gas from the well (MANUALLY)

Its Mainly used for Wireline Activities and to take closed in or flowing pressure .

Used to Open or close the WELL (Safety).

Surface controlled sub-Surface Safety valve Used to open or close the well by Hydraulic control panel. Placed in a landing nipple of the tubing string of wells approximately 150 ft (45 m to 75 m).High pilot Trip on 1000 PSI Low pilot Trip on 250 PSI (Emergency Safety Valve).

Valve is mounted on the X-mass tree assembly that protects flow of fluids against High/Low pressures.

Used to Isolate the well head.

Used to Isolate the flow line for Rig Movement.

Inlet Valve of Separator (Emergency Shutdown Valve).

High pressure (Separator 1st stage 280 psi & 2nd stage 80 psi ) High level (Separator 1st stage 75 % & 2nd stage 75 % ) Low level (Separator 1st stage 25 % & 2nd stage 25% ) High level Flow suction tank low level Flow suction tank high level Gas Scrubber low pressure Instrument Air

Two face separator Used to separate Oil & Gas

The Capacity of all station are 50,000 B/D Except Bu-1 Bank-1 1st Stage Sep Capacity 20,000 B/D.

Separator
Operating Pressure High pressure trip High level trip low level trip Safety valve set

1st Stage
250psig 280psig 75% 25% 350psig

2nd Stage
45psig 80psig 75% 25% 125psig

A tubular device placed vertically in side and out side a larger vessel, through which wells fluids are conducted before entering the larger vessels. (Separate Oil & Gas. Oil will go to the FST and Gas will go to the GASCO Blower. Operating pressure Safety Valve Set 2.77 psig 8.00 psig

Used to Stabilize the Crude for Constant Supply for Booster Pump and no gas will go to Booster Pump.

Its Fixed Roof Tank Operating Pressure High Pressure alarm 1.5 H2O 3. 5 H2O

Low Pressure (Booster Shutdown) 0. 5 H2O

Flapper Valve Open at Breathing Valve Breath IN


Breathing Valve Breath OUT

4.0 H2O 1.0 H2O


3.5 H2O

BU-1

150,000 B/D

BU-2
BU-3 BU-4 OLD

150,000 B/D
200,000 B/D 300,000 B/D

NEW
Station BU-1 BU-2 BU-3 BU-4 Old BU-4 New HI/Level S/Down 32.25 FT 32.25 FT 31.67 FT 35.33 FT 35.33 FT

300,000 B/D
L/Level Alarm 21.42 FT 21.42 FT 21.5 FT 21.58 FT 21.58 FT L/Level S/Down 19.58 FT 19.58 FT 19.58 FT 19. 67 FT 19. 67 FT

This pump will Boost the pressure of fluid received from the FST and pumped to the next station or sulzer or terminal.

Low suction pressure

4 Psig.

Discharge TRV set at

140 Psig.

Used to control Station flow.

Vous aimerez peut-être aussi