MEASUREMENT AND INSTRUMENTATION

BMCC 4743
LECTURE 2: PERFORMANCE OF STATIC
CHARACTERISTICS IN MEASUREMENT
AND INSTRUMENTATION
Mochamad Safarudin
Faculty of Mechanical Engineering, UTeM
2008
JIM07 - FKM - UTeM
2
Contents
Definition of static
Requirement of static characteristics
preservation
Static calibration
Passive & active sensors
JIM07 - FKM - UTeM
3
Definition of Static
The steady state relationship between input
and output of an instrument
Measurement of quantities that are constant
or vary quite slowly with respect to time.
It does not involve differential equations.
All the static performance characteristics are
obtained by one form or another via a
process called static calibration.
JIM07 - FKM - UTeM
4
Contents
Definition of static
Requirement of static
characteristics preservation
Static calibration
Passive & active sensors
JIM07 - FKM - UTeM
5
Requirement of static characteristics
preservation
Precise & Accurate
Measurements that are close to each other
are precise
Measurements that are close to the correct
value are accurate
Measurements can be:
Precise but inaccurate
Neither precise nor accurate
Precise and accurate
JIM07 - FKM - UTeM
6
Examples
(a) Low precision,
low accuracy
(b) Precise not
accurate
(c) Precise and accurate
Three industrial robots were programmed to place components
at a particular point on a table. The target point was the center
of a circle shown below. The results are:
Accuracy
JIM07 - FKM - UTeM
7
0
20
40
20 40
Ideal device
Accuracy at % of FS
Value of measurand
O
u
t
p
u
t

o
f

d
e
v
i
c
e

JIM07 - FKM - UTeM
8
Requirement of static characteristics
preservation
Repeatability
The ability of an instrument to register readings accurately
repeatedly
Linearity
The input and output relationship of a linear transducer can
be represented by the following equation:



where y is the output of transducer, x is the input of
transducer, m is the slope of curve (transfer function), c is
the offset.
Often, the straight line approach is used for certain range of
operation for a non-linear system.
y = mx + c
JIM07 - FKM - UTeM
9
Requirement of static characteristics
preservation
Hysteresis
Hysteresis results in predictable error. May be due
to internal friction, freeplay or looseness in the
mechanism of an instrument.
Also in electrical phenomena (relation between the
output voltage and the input field current in a d.c.
generator) - the effect is due to magnetic
hysteresis of the iron in the field coils.
The transfer functions differ with the increase and
decrease of inputs as shown in the following
figure.
JIM07 - FKM - UTeM
10
G
e
n
e
r
a
l
i
z
e
d

g
r
a
p
h

o
f

o
u
t
p
u
t
/
i
n
p
u
t

r
e
l
a
t
i
o
n
s
h
i
p

w
h
e
r
e

h
y
s
t
e
r
e
s
i
s

i
s

p
r
e
s
e
n
t
.

(
F
r
o
m

P
.

H
.

S
y
d
e
n
h
a
m
,

H
a
n
d
b
o
o
k

o
f

M
e
a
s
u
r
e
m
e
n
t

S
c
i
e
n
c
e
,

V
o
l
.

2
,

C
h
i
c
h
e
s
t
e
r
,

U
.
K
.
,

J
o
h
n

W
i
l
e
y

&

S
o
n
s
,

1
9
8
3
)

Linearity
JIM07 - FKM - UTeM
11
It is highly desirable that the measurement system has a
linier relationship between input and output means that
the change in output is proportional to the change in the
value of the measurand
Deviation from true linearity is called linearity error
Sensitivity
Sensitivity is the ratio of change in
magnitude of the output to the change
in magnitude of the measurand

Sensitivity=D(output)/D(input)
JIM07 - FKM - UTeM
12
Sensitivity and Non Linearity
JIM07 - FKM - UTeM
13
JIM07 - FKM - UTeM
14
Contents
Definition of static
Requirement of static characteristics
preservation
Static calibration
Passive & active sensors
JIM07 - FKM - UTeM
15
Static Calibration
Imagine a situation in which all inputs (desired,
interfering or modifying) except one are kept at some
constant values.
The one input under study is varied over some range
of constant values which causes the output(s) to vary
over some range of constant values.
The input/output relationships developed in this way
comprise a static calibration valid under the stated
constant conditions of all other inputs.
The procedure may be repeated for other inputs for
overall instrument static behaviour
Ultimate objective is to define measurement accuracy
JIM07 - FKM - UTeM
16
Contents
Definition of static
Requirement of static characteristics
preservation
Static calibration
Passive & active sensors
JIM07 - FKM - UTeM
17
Passive & Active Sensors
Sensors are often transducer in that they are devices
that convert input energy of one form into output
energy of another form.
Categorisation of sensors: depends on how they
interact with the environment they are measuring
Passive sensors: they do not add energy as part of the
measurement process but may remove energy in their
operation. E.g. thermocouple converts a physical
temperature into a voltage signal
Active sensors: they add energy to the measurement
environment as part of the measurement process. E.g. in a
radar or sonar system, the distance to some object is
measured by actively sending out a radio (radar) or acoustic
(sonar) wave to reflect off some object and measure its
range from the sensor
JIM07 - FKM - UTeM
18
EXERCISE
What is the meaning of the following
words:
Measurand
Physical quantity
Data
Parameter
Transducer
Actuator
JIM07 - FKM - UTeM
19
ANSWER TO EXERCISE
Measurand: Physical quantity being measured
Physical quantity: Variable such as pressure,
temperature, mass, length, etc
Data: Information obtained from the
instrumentation/measurement system as a result of the
measurements made of the physical quantities
Parameter: Physical quantity within defined (numeric)
limits.
Transducer: A device that converts one form of energy to
another
Actuator: Electronic transducer that converts electrical energy
into mechanical energy
JIM07 - FKM - UTeM