Common Abis Project Review


MoM 11-12 Aug 2011 Update
Telkomsel project
September 2011
NOKIA SIEMENS NETWORKS
NPO Sub Region Indonesia
No Note PIC Target Remark
1 Telkomsel request for Common Abis SOP or
Business Process and Database Parameter
Standardization.
Note : Fallback scenario will be included on
SOP
NSN 15 Augt 2011 Detail on attachment

2 Telkomsel and NSN to conduct socialisation
Common Abis SOP or Bussiness Process in
Region
Tsel/NSN CW37

3 Telkomsel found some inconsistency database
parameter, eg MSTXPMAXCH.
NSN will verify for standarization and
optimization.




NSN 16 Augt 2011 Balinusra Sumalpua




Kalimantan Sumatera

MOM LIST (1/6)
No Note PIC Target Remark
4 Telkomsel found unproper EDAP abis mapping.
NSN have done daily/weekly check on EDAP
check and optimization. NSN send CR to
Telkomsel (SQA Region) regarding EDAP
Optimization











NSN Continuous Already do daily need to
follow up for execution
Detail on attachment
(including GPRS configuration
check)
All areas




Balinusra Sumalpua




Kalimantan Sumatera





5 NSN to propose E1 expansion on sites with
lack of EDAP.
NSN/Tsel-
RAE
16 Augt 2011 Already included on
attachment point No.4

MOM LIST (2/6)
No Note PIC Target Remark
6 Communication about problem, finding, planning,
action, solution, impact analysis, will be communicated
by involving every stakeholder including Tsel
Headquarter
NSN Continuous On going (NSQM need
also in loop Preliminary
report and excel report)

7 Telkomsel requested to provide log alarm per BSC
before and after cutover and send both to Telkomsel
Region or Telkomsel Headquarter
Telkomsel Region : SQA and BSS Team
Telkomsel Headquarter : RAO, RANQ, and RAE
NSN/Tsel Before
and After
Cutover
Region to update

8 NSN will activate QoS and/or Fermaint Alarm before
cutover with approval Telkomsel Regional. Alarm
analysis should be sign by NSN and Tsel.
NSN/Tsel Before
and After
Cutover
Region to update
Below is sample from
Balinusra




9 Telkomsel and NSN have agreement regarding faulty
module on both pre and post cutover.
- In case HW faults identified during perf-test before
cutover, Tsel will perform FLM
- In case HW fault identified during 48 hours after
cutover, NSN will perform FLM
- In case HW faults identified 48 hours after cutover,
Tsel will perform FLM
Alarm clearence report should be included on weekly
report
NSN/Tsel Continuous Region to update

MOM LIST (3/6)
No Note PIC Target Remark
10 Telkomsel and NSN have agreed that only agreed OSS
KPI on site level. Traffic should be maintain and shows
normal trend after cutover, otherwise it would need
NSN explanation and justification. SQA Region should
decide normal or abnormal traffic trends in Cluster
level.
NSN/Tsel Closed Closed

11 Any Change Request on common abis BSC which
impacted to service outage during Lebaran Freeze
network time require Nodin and should be considered
as subject of RAO approval.
Tsel Info Closed

12 NSN will provide list of faulty modules and
transmission problem to Telkomsel with PIC and target
to close.
Tsel 16 Augt 2011 Detail on attachment
Balinusra Sumalpua




Kalimantan Sumatera





MOM LIST (4/6)
No Note PIC Target Remark
13 Telkomsel have identified problem on Remote LMT
connection. Currently happen on almost all BSC
common abis Sumalpua and Kalimantan (eg Jeneponto
and Palopo1). Currently all network outside west java
and jabodetabek handled by 1 Netact OSS.
NSN to investigate and propose for solution
NSN W33 Sumbagteng and
Sumbagsel already in
RC1 (except
FB_Arga_M) done
before Lebaran

14 Sites with or planned with more than 12 Ts EDAP
should used COBA4P12. Subject to inform to RAE for
next action.
NSN Info Detail on attachment
Balinusra
EDAP Tsl <=12 Tsl




Sumalpua & Kalimantan




Sumatera
EDAP Tsl <=12 Tsl





MOM LIST (5/6)
No Note PIC Target Remark
15 Sites with previously (in Siemens) EDGE
capable shall be equipped with minimum two
capable EDGE TRXs after cutover. Subject to
inform to RAE for next action.
NSN/Tsel Info Detail on attachment
Balinusra Sumalpua




Kalimantan Sumatera





16 Both NSN and Tsel-SQA will socialize alarm
supplementary info to regional BSS team to
support first line maintenance.
NSN to propose the timeline
NSN 16 Augt
2011
Detail on attachment


17 NSN to send update schedule implementation
S14 EP9.1 and MP6 11-08
NSN-Care

16 Augt
2011
Detail on attachment






MOM LIST (6/6)
No Note PIC Target Remark
18 NSN have explained Handover Strategy on
Common Abis BSC and have been
implemented on 4 BSC of Sumbagteng area
with result of performance improvement. NSN
will do verification for other areas of common
abis BSC, will propose to implement with
Telkomsel approval.
NSN 16 Augt
2011
Sumbagteng Done, Sumbagsel
already implement in LOROK,
KERINCI, BATURAJA,
LBLINGGAUHC, BETUNG.

19 Found 4 Ater problem on FB_Kambang1 and 2
Ater on Bukit Tinggi2.
NSN will verify and change faulty modul on
TCSM. Telkomsel will do investigation on
Transmission Flickering.
Need to do ASAP due to upcoming new sites
and Lebaran event.
NSN/Tsel W33 Closed

20 Transmission problem on site PT AMP and
Simpang3 Pasaman have been identified on
Backbound problem. Telkomsel need to clear
the problem.
Tsel W33 Closed






MOM LIST SUMBAGTENG
MOM LIST KALIMANTAN
No Note PIC Target Remark
21 Telkomsel request to have traficability comparison
between before and after swap of common abis
site to FMR site.
NSN will provide the comparison at appendices
NSN Will put on
weekly
report in
appendices
Will put on weekly
report in appendices

22 Telkomsel ask why TCH Blocking improved
significantly since August 4th on BSC Inner9. NSN
to provide the action that have been taken.
NSN/Tsel 16-Augt-
2011


23 BTS restart on Sintang4 have been resolve after
upgrade MP6.11-07 and replace COBA from
COBA2P8 to COBA4P12
NSN Closed Closed

24 Sukabangun2 BTS Restart problem should be
investigated to find the root cause (suspect: COBA
problem, but its not happened to all site). This
issue also occurred in Sumalpua. Diagnostic
software have been loaded to suspected restart
BTS (to date no BTS restart occured on problem
site )
NSN/Tsel On
Monitoring

25 PTK Inner 9 & PTK Inner 10 Still have Connect
Lost Voice Problem. Investigation and proposed
action should be made by target
NSN W33

MOM LIST SUMBAGSEL
No Note PIC Target Remark
27 Mushroom sites with different vendor and MSC become
problem in Common Abis area (High Location Update and
Paging) causing low SDSR. Propose re-homing to the same
MSC or Swap Immediately.
Tsel-RAE 16 Augt
2011
Closed (Rehoming
Done)

28 NSN will do TBF DL optimization for BSC Lorok, Kerinci,
Bungo, Sekayu. List of cell will be send to SQA and RANQ
NSN 16 Augt
2011
Parameter trial on
BSC Kerinci alreday
done on Sep
15,2011 with
improvement




29 Found 5 Ater problem on BSC Lorok on TCSM-271,634,
346, 362, and 650 causing silent call and feedback.
NSN CW33 3 TCSM already
fixed, 2 still
Troubleshoot (There
are addition TCSM)

30 NSN will review on LAC capacity for LAC 12428,12430,
12431, and 12432.
NSN 16 Augt
2011

On monitoring

MOM LIST BALINUSRA
No Note PIC Target Remark
31 Telkomsel have identified on restart for some sites on
Common Abis area Bali Nusra.
NSN explained that the problem happen in COBA2P8 during
high traffic, there is SW diagnostic to capture the
symptoms. Workaround solution was replace COBA2P8 to
COBA4P12 but Telkomsel didnt wanted to load diagnostic
patch.
Last update : COBA2P8 has been replaced to COBA4P12
(for 4 sites) on 10 Augt 2011 and no restart sites occurred
on the 4 sites.
NSN On
monitoring
Closed