Vous êtes sur la page 1sur 16

Geberit Pluvia

Training Module 3: Assembly Guidelines


Name der Prsentation, Moderator, Datum 2
56 mm
Geberit Pluvia
Assembly Guidelines
Name der Prsentation, Moderator, Datum 3
56 mm
90 bend directly after outlet
56 mm
Pipe with 90 bend
Geberit Pluvia
Outlet connection
Name der Prsentation, Moderator, Datum 4
Expansion after outlet dia.56mm (12l/s)
max. 90 mm
NO EXPANSION for outlet dia. 90mm
(25l/s) max. 90 mm
Reducer after outlet dia.56mm (12l/s)
max. 40 mm
outlet dia. 90mm (25l/s) max. 75 mm
Geberit Pluvia
Outlet connection with expansion and reducer
Name der Prsentation, Moderator, Datum 5
All types of reducers permitted!
Recommended vertical:
concentric reducer
Position 2
Recommended horizontal:
eccentric reducer
Position 1
Position 1 Position 2 Position 3
Geberit Pluvia
Reducers
Name der Prsentation, Moderator, Datum 6
P
l
u
v
i
a

Below foundation slab
Above foundation slab
Geberit Pluvia
Connection to conventional system
Name der Prsentation, Moderator, Datum 7
Inside manhole
Pluvia
conventional
Before manhole
min. 2 m
P
l
u
v
i
a

c
o
n
v
e
n
t
i
o
n
a
l

Geberit Pluvia
Connection to conventional system
Name der Prsentation, Moderator, Datum 8
after manhole
open Pluvia systems are NOT PERMITTED!
Pluvia
conventional
Pluvia
conventional
Geberit Pluvia
Connection to conventional system
Name der Prsentation, Moderator, Datum 9
transition from Pluvia to conventional
Direct into lake or river
Pluvia
Geberit Pluvia
Connection to conventional system
Name der Prsentation, Moderator, Datum 10
Overflows on both side must always be provided!
Geberit Pluvia
Safety overflow for gutter
Name der Prsentation, Moderator, Datum 11
Always provide at least 2 overflows!
Geberit Pluvia
Safety overflow for flat roof
Name der Prsentation, Moderator, Datum 12
After finishing of waterproofing layer, the Pluvia outlet can be used as an outlet for
temporary drainage. For this application the protection cover has a small opening which
can be opened through removing of the label.
Geberit Pluvia
Temporary roof drainage
Name der Prsentation, Moderator, Datum 13
If flat roofs are covered with slaps instead of gravel, ensure that only plastic bound slaps are
use wherever possible. The outlets must be protected against sintering if the slaps containing
cement are used. This protection should take the form of a bed of gravel approx. 1 m x 1 m in
extend around the inlet.
Reason, the rainwater washes the lime out of the cement slaps, this lime is flushed into the
Pluvia pipe system. Lime deposits on the inner wall of the pipe reduces slowly the diameter.
Geberit Pluvia
Protection against sintering
Name der Prsentation, Moderator, Datum 14
Scratch stainless steel sheet with
sand paper or steel brush
Fix one layer of bitumen foil onto
concrete slab
Flame outlet onto layer of
bitumen foil
Fix outlet onto roof construction
Geberit Pluvia
Mounting instruction for bitumen foil onto contact sheet
Name der Prsentation, Moderator, Datum 15
Install bitumen foils with a flame
Apply a layer of liquid bitumen
Clean contact sheet
Cover contact sheet with bitumen
primer completely
Geberit Pluvia
Mounting instruction for bitumen foil onto contact sheet
Name der Prsentation, Moderator, Datum 16
Flat roofs and gutters have to be serviced regularly. This requires the removal of any
leaves, dirt or plants to avoid any blockage. This regular maintenance has to be done in
accordance with the prevailing environmental conditions (weather, trees, etc. ) and has to
include the cleaning of the Geberit Pluvia outlets and baskets.
In doing so, the cover basket has to be removed to enable access for the cleaning of the
outlet element itself. The frequency of cleanings through the year has to be defined by the
proprietor within the planned maintenance programme.
Pluvia outlet 25 l/s
Pluvia outlet 12 l/s
Geberit Pluvia
Maintenance instructions
!