0 évaluation0% ont trouvé ce document utile (0 vote)
65 vues16 pages
This document provides assembly and installation guidelines for the Geberit Pluvia rainwater system. It discusses allowable pipe diameters and connections after the outlet, types of reducers and their recommended positions, connecting Pluvia to conventional drainage systems, providing overflows, mounting bitumen foil, and maintenance requirements including regular cleaning of outlets and removal of debris from flat roofs and gutters.
This document provides assembly and installation guidelines for the Geberit Pluvia rainwater system. It discusses allowable pipe diameters and connections after the outlet, types of reducers and their recommended positions, connecting Pluvia to conventional drainage systems, providing overflows, mounting bitumen foil, and maintenance requirements including regular cleaning of outlets and removal of debris from flat roofs and gutters.
This document provides assembly and installation guidelines for the Geberit Pluvia rainwater system. It discusses allowable pipe diameters and connections after the outlet, types of reducers and their recommended positions, connecting Pluvia to conventional drainage systems, providing overflows, mounting bitumen foil, and maintenance requirements including regular cleaning of outlets and removal of debris from flat roofs and gutters.
Name der Prsentation, Moderator, Datum 2 56 mm Geberit Pluvia Assembly Guidelines Name der Prsentation, Moderator, Datum 3 56 mm 90 bend directly after outlet 56 mm Pipe with 90 bend Geberit Pluvia Outlet connection Name der Prsentation, Moderator, Datum 4 Expansion after outlet dia.56mm (12l/s) max. 90 mm NO EXPANSION for outlet dia. 90mm (25l/s) max. 90 mm Reducer after outlet dia.56mm (12l/s) max. 40 mm outlet dia. 90mm (25l/s) max. 75 mm Geberit Pluvia Outlet connection with expansion and reducer Name der Prsentation, Moderator, Datum 5 All types of reducers permitted! Recommended vertical: concentric reducer Position 2 Recommended horizontal: eccentric reducer Position 1 Position 1 Position 2 Position 3 Geberit Pluvia Reducers Name der Prsentation, Moderator, Datum 6 P l u v i a
Below foundation slab Above foundation slab Geberit Pluvia Connection to conventional system Name der Prsentation, Moderator, Datum 7 Inside manhole Pluvia conventional Before manhole min. 2 m P l u v i a
c o n v e n t i o n a l
Geberit Pluvia Connection to conventional system Name der Prsentation, Moderator, Datum 8 after manhole open Pluvia systems are NOT PERMITTED! Pluvia conventional Pluvia conventional Geberit Pluvia Connection to conventional system Name der Prsentation, Moderator, Datum 9 transition from Pluvia to conventional Direct into lake or river Pluvia Geberit Pluvia Connection to conventional system Name der Prsentation, Moderator, Datum 10 Overflows on both side must always be provided! Geberit Pluvia Safety overflow for gutter Name der Prsentation, Moderator, Datum 11 Always provide at least 2 overflows! Geberit Pluvia Safety overflow for flat roof Name der Prsentation, Moderator, Datum 12 After finishing of waterproofing layer, the Pluvia outlet can be used as an outlet for temporary drainage. For this application the protection cover has a small opening which can be opened through removing of the label. Geberit Pluvia Temporary roof drainage Name der Prsentation, Moderator, Datum 13 If flat roofs are covered with slaps instead of gravel, ensure that only plastic bound slaps are use wherever possible. The outlets must be protected against sintering if the slaps containing cement are used. This protection should take the form of a bed of gravel approx. 1 m x 1 m in extend around the inlet. Reason, the rainwater washes the lime out of the cement slaps, this lime is flushed into the Pluvia pipe system. Lime deposits on the inner wall of the pipe reduces slowly the diameter. Geberit Pluvia Protection against sintering Name der Prsentation, Moderator, Datum 14 Scratch stainless steel sheet with sand paper or steel brush Fix one layer of bitumen foil onto concrete slab Flame outlet onto layer of bitumen foil Fix outlet onto roof construction Geberit Pluvia Mounting instruction for bitumen foil onto contact sheet Name der Prsentation, Moderator, Datum 15 Install bitumen foils with a flame Apply a layer of liquid bitumen Clean contact sheet Cover contact sheet with bitumen primer completely Geberit Pluvia Mounting instruction for bitumen foil onto contact sheet Name der Prsentation, Moderator, Datum 16 Flat roofs and gutters have to be serviced regularly. This requires the removal of any leaves, dirt or plants to avoid any blockage. This regular maintenance has to be done in accordance with the prevailing environmental conditions (weather, trees, etc. ) and has to include the cleaning of the Geberit Pluvia outlets and baskets. In doing so, the cover basket has to be removed to enable access for the cleaning of the outlet element itself. The frequency of cleanings through the year has to be defined by the proprietor within the planned maintenance programme. Pluvia outlet 25 l/s Pluvia outlet 12 l/s Geberit Pluvia Maintenance instructions !