Vous êtes sur la page 1sur 20

NodeB operation and maintenance

ISSUE 1.0

Huawei Confidential. All Rights Reserved

Objectives

Upon completion of this course, you will be


able to:

Master NodeB operation and maintenance


system;

Master the alarm management system

Internal Use

References

31026663- BTS3812E
maintenance )

Routine

Internal Use

Chapter 1 O&M system

Chapter 2 Alarm management system

Internal Use

O&M System

Provides two operation modes


GUI
MML commands
Operations
Software Management
Equipment Maintenance
Cell management
Tracing Management
Real time monitoring

Internal Use

O&M System

Internal Use

O&M System

Internal Use

O&M System operations

Software management
Upload and download data files
Upload and download data configuration file
Upload maintenance log file
Upload equipment archives file
Upgrade NodeB software
Download NodeB software
Activate NodeB software
Activate RRU software
Synchronize version

Internal Use

O&M System operations

Upgrade NodeB BOOTROM


Download NodeB BOOTROM
Activate NodeB BOOTROM
Activate RRU BOOTROM
Upgrade NodeB patch
Download NodeB patch
Activate NodeB patch

Internal Use

O&M System operations

Equipment Maintenance
List NodeB software version (LST VER/ LST SOFTWARE)
Modify NodeB time (MOD TM)
Modify password (MOD PWD)
Reset NodeB (RST SYS)

10

Display board state (DSP BRD)


List active alarm (LST ALMAF)
List board version (DSP BRDVER)
Display E1/T1(STM-1) state (DSP E1/T1) (DSP STM1)
Display E1/T1(STM-1) work mode
Reset board (RST BRD)
Add/delete board (ADD BRD, RMV BRD)

Internal Use

O&M System operations


Cell

11

management
Query cell status (LST LOCELL)
Query cell status (DSP LOCELL)
Block/unblock cell (BLK CELL,UBL CELL)
Audit resource (ADT RES)

Internal Use

O&M System operations

Trace

12

Iub Interface message


Start/stop tracing Iub interface
Browse traced message
View explanation of traced message
Save traced message
Offline view traced message
Set traced message window display

Internal Use

O&M System operations

Performance

13

test
CPU/DSP occupancy
Cell Service resource occupancy
RTWP measurement
RX frequency scanning
Service resource occupancy

Internal Use

Chapter 1 O&M system

Chapter 2 Alarm management system

14

Internal Use

Alarm Management System

Alarm Type

15

Description

Fault Alarm

Alarms generated due to hardware equipment fault or major


function exception can be cleared after handling. The system
will report cleared alarm indicating the fault is cleared. Fault
alarms' generation and clearance are of one-to-one
correspondence relationship. Generally, severity of fault
alarm is higher than that of event alarm.

Event Alarm

Accidental alarm during equipment operation reflects the


transient state of equipment operation. It only indicates the
system is in alarm state at a certain time. There is no cleared
alarm for event alarms. And some event alarms are generated
periodically.

Internal Use

Alarm Management System

Alarm Severity

16

Description

Critical Alarm

This type of alarm affects the services provided by the


system, so it must be handled at once. Even if the alarm is
generated out of working-hours, measures should be taken at
once. For example, when some equipment or resource is
completely unavailable, it is necessary to restore it.

Major Alarm

The major alarm affects QoS, for example, the QoS of a


device or resource is impaired. It requires immediate
handling.

Internal Use

Alarm Management System


Alarm Severity

17

Description

Minor Alarm

The minor alarm does not affect QoS. It requires


handling at a proper time against potential faults.

Warning Alarm

The warning shows a potential error that may


affect service .It may require handling in some
cases.

Internal Use

Alarm Management System


Network Management Category

18

Description

Power System

Alarms of the power system (e.g. DC 48V) .

Environment System

Alarms of equipment room environment


temperature, humidity and door control) .

Signaling System

Alarms of channel associated signaling and SS7.

Trunk System

Alarms of trunk circuit and trunk board.

Hardware System

Alarms of board device (e.g. clock, CPU) .

Software System

Alarms of software.

Operation System

Alarms generated during system operation.

Communication System

Alarms of communication system.

QoS

Alarms of QoS.

Processing Error

other alarms

(e.g.

Internal Use

Alarm Management System

19

Functions:
Browse alarm information
Query alarm information
Maintain alarm information
Set fault alarm reporting attribute
Print/save alarm information

Internal Use

20

Internal Use