Académique Documents
Professionnel Documents
Culture Documents
BTS3900 family
BTS3900 indoor
BTS3900A outdoor
www.huawei.com
Huawei Confidential
BTS3900 indoor
Huawei Confidential
Page 2
BTS3900A Cabinet
The
Configuration
Type
RF cabinet
600
480
700
APM30 power
distribution cabinet
600
480
700
Cabinet base
600
480
200
Huawei Confidential
Page 3
Huawei Confidential
Page 4
Huawei Confidential
Page 5
BBU Board--GTMU
The
(GTMU)
controls and manages the entire BTS. It provides interfaces related to
the
reference
clock, power
supply, OM,
and external alarm collection.
The
GTMU performs
the following
functions:
Controls,
Supports
Huawei Confidential
Page 6
BBU Board--GTMU
Ports on the Panel
Port
Type
Description
CPRI0
CPRI5
SFP connector
Provides the input and output of optical and electrical transmission signals
ETH
RJ45 connector
FE0
RJ45 connector
FE1
DLC connector
USB
USB connector
TST
USB connector
E1/T1
DB26 male
connector
Provides the input and output of the four E1/T1 signals between the GTMU and the UELP
or between the GTMU and the BSC.
Huawei Confidential
Page 7
BBU Board--UELP
The universal E1/T1 lightning protection unit (UELP) provides lightning
protection for four E1/T1 signals.
Huawei Confidential
Page 8
Label
Connector Type
Description
Port for
transceiving
RF signals
ANT_RXB
DIN connector
CPRI
CPRI0
SFP female
connector
ANT_TX/RXA
CPRI1
Interconnection
port for RF
Receive signals
RX_INB
RX_OUTA
PWR
3V3 power
connector
Feeding power.
Monitoring port
MON
RJ45 connector
Huawei Confidential
Page 9
GRFU
Relative
position
DRFU
Relative
position
Port for
transceiving
RF signals
ANT_TX/RX lower
A
ANT1
upper
ANT_RXB
upper
ANT2
lower
CPRI
CPRI0
lower
CPRI0
upper
CPRI1
upper
CPRI1
lower
Interconnectio RX_INB
n
port for RF
Receive
RX_OUTA
signals
upper
Rx_1 in
Monitoring
port
existence
MON
Rx_1 out
lower
Rx_2 in
Rx_2 out
nonexisten
ce
Huawei Confidential
Page 10
Huawei Confidential
Page 11
Huawei Confidential
Page 12
PDU
Module
The PDU (short for Power Distribution Unit) performs AC or DC power
distribution.
The AC distribution functions of the PDU are as follows:
Supplies two AC power outputs with the maximum current of 10 A to the heaters
of the power cabinet and the heating film of the battery cabinet.
Reports the surge protection alarms of the AC input power .
Huawei Confidential
Page 13
and the -48 V 100 AH. The batteries can be grouped into the following
combinations:
When
100 AH through connecting the upper and the lower battery groups in parallel.
When
Huawei Confidential
Page 14
Huawei Confidential
Page 15
Huawei Confidential
Page 16
Huawei Confidential
Page 17
The 110 V AC power interface box and the 220 V AC power interface box
have the same components, but they are different in MCB specifications.
Huawei Confidential
Page 18
Internal DDF
Twisted Pair DDF
The twisted pair DDF provides the access for eight twisted pair E1s. It is 1
U in height and does not provide the lightning protection function.
Huawei Confidential
Page 19
Battery
The power cabinet can house 1 to 3 groups of -48 V 12 AH
batteries, which can form the -48 V 12 AH battery group system, the
-48 V 24 AH system, or the -48 V 36 AH system. The details are as
follows:
The -48 V 12 AH or -48 V 24 AH battery group is installed in the 3 U
space at the bottom, and the remaining 5 U space can be used to install the
user devices.
The -48 V 36 AH battery group is installed
in the 6 U space at the bottom, and the
remaining 2 U space can be used to install
the user devices.
Huawei Confidential
Page 20
Sensors
Huawei Confidential
Page 21
Sensors
Temperature Sensor
The temperature sensors of the APM30 consist of the air inlet temperature
sensor, internal ambient temperature sensor, and the air outlet temperature
sensor.
Huawei Confidential
Page 22
Thank you