Vous êtes sur la page 1sur 32

TD LTE eNodeB

Equipment
Commissioning

TDD Team

LTE eNodeB Commissioning Workflow

contents

Part 1 Commissioning by LMT

Part 2 Commissioning by U-KEY

Part 3 Commissioning by PnP

Commissioning by LMT

Delivering the .xml File to the eNodeB Side Through the LMT

CC IP:192.254.1.16

Commissioning by LMT

Delivering the .xml File to the eNodeB Side Through the LMT

Commissioning by LMT

Manually Configuring the Transmission Data on the eNodeB


Side Through the LMT, The parameters include :

PhyLayerPort

EthernrtLink

IpLayerConfig

BandwidthResource

ItfUniBts

Commissioning by LMT

Configuring PhyLayerPort

Select View --> Data View to open the Data View dialog box.

Commissioning by LMT

Right-click PhyLayerPort under the TransportNetwork node on the


left-sided navigation tree.

Right-click in the blank area of the displayed dialog box, and then
select ADD. Then, click CONFIRM to add one port record of the
physical layer.

Commissioning by LMT

Double-click the added port record, and then configure the


port parameters of the physical layer according to the actual
planning.

Commissioning by LMT

Configuring EthernetLink

Right-click EthernetLink on the left-sided navigation tree

Right-click in the blank area of the displayed dialog box, and then
select ADD. Then, click CONFIRM to add one configuration
record of the Ethernet link layer.

10

Commissioning by LMT

Double-click the new EthernetLink record, and then modify the


EthernetLink parameter according to the transmission
planning data

11

Commissioning by LMT

Configuring IpLayerConfig

Right-click IpLayerConfig on the left-sided navigation tree.

Right-click in the blank area of the displayed dialog box, and then select
ADD. Then, click CONFIRM to add one IP configuration record.

12

Commissioning by LMT

Double-click the new IP configuration record, and then modify


the configuration data on the IP layer according to data
planning of site transmission.

13

Commissioning by LMT

Configuring the BandwidthResourceGroup

Right-click BandwidthResourceGroup on the left-sided navigation tree.

Right-click in the blank area of the displayed dialog box, and then select
ADD. Then, click CONFIRM to add one bandwidth resource group
configuration record.

14

Commissioning by LMT

Double-click the new bandwidth resource group record and


modify the bandwidth resource group parameters.

15

Commissioning by LMT

Click BandwidthResource under the BandwidthResourceGroup node.

Right-click in the blank area of the displayed BandwidthResource dialog


box, and then select ADD. Then, click CONFIRM to add one bandwidth
resource configuration record.

16

Commissioning by LMT

Double-click the added bandwidth resource record and modify


the bandwidth resource configuration

17

Commissioning by LMT

Configuring the OMCB Channel

Right-click ItfUniBts on the left-sided navigation tree.

Right-click in the blank area of the displayed dialog box, and then select
ADD. Then, click CONFIRM to add one OMCB channel record.

18

Commissioning by LMT

Double-click the new OMCB configuration record and configure


the OMCB channel according to the planned parameters.

19

Commissioning by LMT

Making Parameters Take Effect

Click Export to base station in the Data View dialog box.

20

Commissioning by LMT

Verification result Interface

21

Commissioning by LMT

Select Deliver modified data from the displayed


Configuration type selection dialog box. Then, click OK.

22

Commissioning by LMT

Version Management

Double-click the EOMS.jar file under the copy_version


directory. The EOMS Login dialog box is displayed

23

Commissioning by LMT

ZX SDR LMT-EOMS Window Version Management Mode

24

Commissioning by LMT

Version upgrade please refer to TD LTE (V3.10.10)


eNodeB Commissioning Guide (Using LMT)_R1.0 3.2
Managing Versions

25

contents

Part 1 Commissioning by LMT


Part 2 Commissioning by U-KEY
Part 3 Commissioning by PnP

Commissioning by U-KEY

Automatically Delivering the .xml File to the eNodeB Side


Through U-Key:

U-Key data synchronization is already finished through Umaker

Join the U-Key to the Mini USB port on the CC board through the
cable adapter, as shown in Figure. When the connection is
proper, the CC board will be automatically restarted

27

Commissioning by U-KEY

U-Key Making
Procedures

28

contents

Part 1 Commissioning by LMT

Part 2 Commissioning by U-KEY

Part 3 Commissioning by PnP

Commissioning by PnP

eNodeB ID & EID input

30

Commissioning by PnP

EID of a CC Board

31

Vous aimerez peut-être aussi