Académique Documents
Professionnel Documents
Culture Documents
A
PRACTICAL TRAINING SEMINAR
ON
DHOLPUR COMBINED CYCLE POWER PROJECT
Submitted By:
RITESH GOYAL
(11ESKEE087)
SATENDRA SINGH CHAUHAN
(11ESKEE096)
CONTENTS
INTRODUCTION
WHY ITS CALLED DCCPP ?
WATER HOUSE
COMBINED CYCLE POWER PLANT
OPEN CYCLE
CLOSE CYCLE
ARRANGEMENT OF COMBINED CYCLE
COMPONENTS OF GAS TURBINE POWER PLANT
PLANT LAYOUT
RATINGS
ADVANTAGES OF COMBINED CYCLE PLANTS
HOW TO IMPROVE THE EFFICIENCY??
APPLICATION OF GAS TURBINE
GAS TURBINE INSTALLATION IN RAJASTHAN
REFERENCE
INTRODUCTION
DCCPP is situated in the outskirts of Dholpur which is about
55Km south west of Agra.
Dholpur was considered as an ideal location for setting up of a
gas power plant having regards to the availability of land & water.
DCCPP is project of Rajasthan Vidhyut Utpadan Nigam Ltd
setup in 2007.
Plant capacity is 330 MW (2 Gas Turbine 110MW each and 1
Steam Turbine 110 MW).
INTRODUCTION (CONT)
Unit No
Capacity(MW)
Synchronising Date
GT 110
29.03.2007
GT 110
16.06.2007
ST 110
27.12.2007
Environmental profile:
Based on Gas. This Project is Compatively safe in view of
environment & water pollution.
Area
143 Bigha
Water Requirement
Fuel Requirement
1.5 MM SC MD gas
Fuel Supplier
ONGC
Fuel Transporter
GAIL
WATER HOUSE
Reservoir water:-Two reservoir tanks are present in this plant
. Area of each reservoir tank is 100x100 m 2. At a time only
one dam is used.
First of all reservoir water convert into de-mineral water
which is used for steam generation.
Alum is added into reservoir water to remove clay. And then
Cl2 is add into water which water is used in power plant for
steam generation.
For convert reservoir water into de-mineral water following motors &
pumps are used. These pumps are connected in two series. At a time
one series is used.
1) DMF(Dual Media Filter)
2) ACF(Activated Carbon Filter)
3) SAC(Strong Acid Cation)
4) DGWST(Degasifire Water Storage Tank)
5) WBA(Weak Base Anion unit)
OPEN CYCLE
In open cycle plant fuel is mixed
with air in combustion chamber.
Heat rejection process occurs in
the atmosphere as the turbine
exhaust is discharged into
atmosphere.
CLOSE CYCLE
In closed cycle plant fuel is not
mixed with the working medium.
The heat rejection process occurs
in heat exchanger or recooler.
ARRANGMENT OF COMBINED
CYCLE
PLANT LAYOUT
RATINGS
STEAM TURBINE:
SPEED-3000 RPM
STEAM PRESSURE-76
Kg/cm2
TEMPRATURE-518 DEGREE
CENT.
TURBO GENERATOR:
CAPACITY-126.2MW
P.F.-0.85 LAGGING
FREQUENCY-50 Hz
COOLENT-AIR
REFERENCES
http://www.rvunl.com/Dholpur.html
http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=790952
www.authorstream.com/Presentation/anjalibrahmi-1324
306-ap-1
Power Plant Engineering by Arora Domkundwar
Generation of Electrical Energy by B.R. Gupta
!
u
o
y
k
n
Th a