Vous êtes sur la page 1sur 17

HSDPCCH Power Offset Trial

Prepared by: Syed Abdul Quader

Agenda

1. Introduction
2. Trial Results
3. Summary

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.

Introduction

3 | UA7.1.3 KPI Investigation Methodology | Feb. 2011

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.

Introduction
As the DPDCH power can be reduced in soft handover due to power control
command received from a non serving cell, the HS-DPCCH power offset must be
configured to a high value to ensure CQI and ACK/NACK decoding robustness in
soft handover
In case of only 1 RL is configured in the active set, less power is available for EDCH leading to uplink throughput decrease

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.

Introduction

Parametric Modifications:

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.

Trial Results

6 | UA7.1.3 KPI Investigation Methodology | Feb. 2011

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.

Trial Results

The Trial was applied on 26th August 2014 (16:00hrs) comprising or 7


Sites
UAJREA5140/UAJREA5247/UAJR3340/UAJREA5136/UAJR3339/UAJREA5138/
UAJREA5139/
SKAKA DUMAT AL JANDAL
AREA
WAS SELECTED FOR TRIAL
ON 7 SITES

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.

Trial Results (Throughput Metrics )

Neither Improvement Nor the Degradation is Observed in Hsupa Thpt.

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.

Trial Results (UL Load)

RSSI and UL Load was reduced a little due to a lower HS-DPCCH power offset.
9 | UA7.1.3 KPI Investigation Methodology | Feb. 2011

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.

Trial Results (E-DCH HARQ Retransmissions)


The number of E-DCH HARQ retransmission decreased a little

10 | UA7.1.3 KPI Investigation Methodology | Feb. 2011

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.

Trial Results (SHO Failure Rate)


Sho Failure Rate had increased & CSIrat Ho Attempts Increase

11 | UA7.1.3 KPI Investigation Methodology | Feb. 2011

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.

Trial Results (HSDPA Throughput)


From the metrics, we can see slight degradation on HSDPA throughput.

12 | UA7.1.3 KPI Investigation Methodology | Feb. 2011

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.

Drive Test Results (HSUPA Throughput Mobility)

PRE

771Kbps

13 | UA7.1.3 KPI Investigation Methodology | Feb. 2011

POST

877Kbps

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.

Drive Test Results (HSUPA Throughput Stationary)

PRE

14 | UA7.1.3 KPI Investigation Methodology | Feb. 2011

POST

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.

Trial Results (KPI Summary)


From the metrics, Very Little Improvement is on Hsupa Thpt
We can see that HsdpaThroughput is slightly Reduced

15 | UA7.1.3 KPI Investigation Methodology | Feb. 2011

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.

Summary

16 | UA7.1.3 KPI Investigation Methodology | Feb. 2011

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.

Summary

Advantages:
Good Improvement on Field User Hsupa Thpt
Disadvantages:
-As Expected, Sho Failures had increased

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.

Vous aimerez peut-être aussi