CONTENTS
Objectives
Introduction
Existing system
Proposed Topology
Advantages
Drawbacks
Output Voltages
Calculation Of Losses
Conclusions
References
1/12/2015
OBJECTIVES
Cascaded Multilevel Inverter using developed
H-bridges inverter
It requires a lesser number of dc voltage
sources and switches
Dc source is given to the Buck- Boost
converter and it is fed to Multilevel Inverter
1/12/2015
INTRODUCTION
Multilevel inverters are used in high power
applications .
Generate a stepped voltage waveform by using
with a number of dc voltage sources
Need of filters is reduced by increasing the
voltage level
1/12/2015
Continued
In high power applications, Cascaded inverter
can easily interface with Solar PV module and
fuel cells
Advantages such as Improve power quality,
reduce lower order harmonics
1/12/2015
EXISTING SYSTEM
1/12/2015
1/12/2015
BUCK-BOOST CONVERTER
Buck-boost converter provides an output voltage
can be either higher or lower than the input
voltage
The output voltage polarity is opposite to that of
the supply voltage
Advantage of Buck-boost converter is the
increased efficiency
1/12/2015
BUCK-BOOST CONVERTER
1/12/2015
10
Vin(max)
Vin(min )
Vout
Dbuck =
Dboost =
1/12/2015
11
PROPOSED TOPOLOGY
1/12/2015
12
1/12/2015
13
SEVEN-LEVEL INVERTERS
PROPOSED TOPOLOGY
By adding two unidirectional power switches and
one dc voltage source obtain Developed H-bridge
inverter
Simultaneous turn-on of SL,1 and SL,2 or SR,1 and
SR,2 causes the voltage sources to short-circuit
And Voltage source is connected with the DC-DC
converter to step up and Step down the voltage input
1/12/2015
15
1/12/2015
16
1/12/2015
17
18
ADVANTAGES
No. of Levels of the Developed H-bridge Inverter is
Increased with reduced no. of Voltage source and
switch
By changing the switching duty cycle of the
converter the Output of the converter can be varied.
Desired Voltage Level can be obtained by using
DC-DC converter.
1/12/2015
19
DRAWBACKS
Voltage Ripple is presented in the Output
Waveform.
For Higher current rating, Constant load is
used to reduced the ripple current
Higher ripple current is produced at the time of
changing the duty cycle.
1/12/2015
20
OUTPUT VOLTAGE
1/12/2015
21
1/12/2015
22
1/12/2015
23
CALCULATION OF LOSSES
Mainly, two kinds of losses conduction and
switching losses are associated
Switches include IGBTs and diodes
The conduction losses of an IGBT pc,IGBT(t)
and a diode pc,D(t) are calculated
1/12/2015
24
CONDUCTION LOSSES
Conduction losses of an IGBT and a diode are
calculated as follows.
pc,IGBT(t) =VIGBT + RIGBTi(t)i(t)
pc,D(t) = [VD + RDi(t)] i(t)
1/12/2015
25
AVERAGE
CONDUCTION POWER LOSS
Average value of the conduction power loss
(Pc) of the multilevel inverter can be written as
1/12/2015
26
1/12/2015
27
CONCLUSIONS
Harmonics is reduced
By adding two switches for H-bridge inverters
to generate seven voltage levels
Comparison results shows, the proposed
topology requires a lesser number of IGBTs.
1/12/2015
28
REFERENCES
[1] E. Babaei and S. H. Hosseini, Charge balance control methods for
asymmetricalcascade multilevel converters, in Proc. ICEMS,
Seoul, Korea, 2007, pp. 7479.
29
REFERENCES
[4] M. Manjrekar and T. A. Lipo, A hybrid multilevel inverter topology
for drive application, in Proc. APEC, 1998, pp. 523529.
1/12/2015
30
THANK YOU