REFERENCES
ASHRAE FUNDAMENTALS-2013
ASHRAE 62.1-2007, VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY
ASHRAE 90.1-2013, ENERGY STANDARD FOR BUILDINGS EXCEPT LOW RISE RESIDENTIAL
BUILDINGS
Local Standards as per Project Location
Core Design - Unilever
HVAC SYSTEMS
Simple Split AC System (DX Type)
Duct able Split AC System
Package Type AC System
Air Cooled Type Condenser
Water Cooled Type Condenser
VRV / VRF SYSTEM
Air Cooled Type
Water Cooled Type
Central Air Conditioning System
Air Cooled Type
Water Cooled Type
Evaporator Unit with Copper Coil, Blower Fan, Filter, thermostat, cordless remote control inside
the conditioned space
2.
Condenser Unit which contains Compressor, Expansion Valve, Condenser Coil , Condenser fan
located outside the conditioned space to discharge room heat to the ambient
3.
Copper Piping with Insulation prevents the undue heat losses from surrounding which deteriorate
the capacity of AC Equipment and leads to de-rating.
4.
Refrigerant inside the copper tube which may be R-22 (Chloro-di-fluoro-methane), R410a, R407c.
(R134a+R410a)
5.
Available in Capacity : 0.8 TR, 1.0 TR, 1.2TR, 1.5 TR, 1.83 TR & up to 3 TR,
6.
7.
The initial investment is less for these units but OPEX may be higher depending upon
Ambient Temperature
Evaporator Unit with Copper Coil, Fan, Filter, thermostat, cordless, corded remote control inside the
conditioned space
2.
Condenser Unit which contains Compressor, Expansion Valve, Condenser Coil, Condenser fan located
outside the conditioned space to discharge room heat to the ambient
3.
Copper Piping with Insulation prevents the undue heat losses from surrounding which deteriorate the
capacity of AC Equipment and leads to de-rating.
4.
Refrigerant inside the copper tube which may be R-22 (Chloro-di-fluoro-methane), R410a, R407c.
(R134a+R410a)
5.
6.
7.
The initial investment is less for these units but OPEX may be higher depending upon
Ambient Temperature
5 .
The complete package can be located outside the conditioned space which may be shaded or even
open to atmosphere however the proffered location is well ventilated place and covered under
shades which prevent incidental radiations on condenser coil.
2.
Since this is package unit and all necessary piping's are factory fitted located inside the casing does
not require any external insulation to be done by third party contractor on piping.
3.
All the supply & return air duct connecting to conditioned space shall be provided with adequate
insulation which prevent the heat losses, condensation and protection from weather which may lead
to deteriorate the capacity of AC Equipment and leads to de-rating.
4.
Refrigerant inside the copper tube which may be R-22 (Chloro-di-fluoro-methane), R410a, R407c.
(R134a+R410a)
5.
6.
7.
These are available with Air Cooled as well as water cooled type condenser, the water cooled type
unit has more efficiency as water has more specific heat compared to air
8.
The initial investment is less for these units but OPEX may be higher depending upon
. | Copyright
Confidential
Poor maintenance
L&T Technology of
Services
compressor
The complete package can be located outside the conditioned space which may be shaded or even open
to atmosphere.
2.
The piping is made of copper with proper insulation and can be connected to multiple indoor units through
a common header of refrigerant piping.
3.
All the supply & return air duct connecting to conditioned space and package units shall be provided with
adequate insulation which prevent the heat losses, condensation and protection from weather which may
lead to deteriorate the capacity of AC Equipment and leads to de-rating.
4.
Refrigerant inside the copper tube is R410a. This is mixture of two refrigerant (R-32 difluoromethane +
R125
pentafluoroethane)
5.
Available in Capacity : 0.6 TR and up to 8 TR of maximum capacity while outdoor unit capacity is
around 24 TR
6.
USE : All Type of offices, Auditorium, Banquette Halls, Classroom, Hotel Rooms etc.
7.
The initial investment is High even compared with Central Air Conditioning System but it gives advantage
in case of
application with high diversity.
8.
10
Refrigerants
Following are normally used refrigerants for air conditioning Application
Sl. No
Refrigerant
Actual Name
R-22
Chloro-difluoro-methane
R-134a
Tetrafluroethane
R-410a
R-407c
R-717
Ammonia
R-718
Water
11
12
13
14
Instrumentation
THANK YOU