Académique Documents
Professionnel Documents
Culture Documents
(FPMR)
1
2
3
4
MDR Tributary
(HUB 800)
1.
2.
3.
4.
Connection Amphenol to RJ 45
Power Injector
Indoor Power Injector
Sample of Datafill
Flexi Hub800
IP default flexi hub800
OOB
: 192.168.254.100
DCN
: 192.168.255.100
VLAN ID Hub : 127
Reset IDU
Pada langkah-langkah diatas, reset IDU tidak akan merubah DCN yang sebelumnya sudah kita setting
ODU
IP default Radio FPMR
OOB
: 192.168.255.3
DCN
: 0.0.0.0
VLAN ID ODU : 4096
Kedua IP di atas jika direset ODU, DCN akan beubah
Reset ODU
masuk ke Web LCT dengan IP defalut melalui port OBB dengan IP: 192.168.255.3.
Masuk ke status & config -> masuk ke system status pilih configurasi default pilih reset.
Setting IP in your PC
192.168.254.xxx (range 1-254)
192.168.255.xxx (range 1-254)
Default Connect
Attention : always unchecked Add PC IP Address !!!
Default Connect
Attention : always unchecked Add PC IP Address !!!
Step 1
Change IP DCN
and Default
gateway according
data fill
Step 2
Click Apply
Step 1
Click Management VID
Step 2
Change ID VLAN
according data fill
Step 3
Click Apply
Step 1
Click OK
Step 1
Time and Date
Step 2
Used PC time
and change Time
zone
Step 3
Click Apply
Step 1
Click Port View
Step 4
Select
FPMR(P)
Step 5
Select Mode
according data fill
Step 6
Select enable if ODU
connected to port 3 or 4
Step 7
Select PWR on Integrated
device if ODU connected
to port 3 or 4
Step 2
Select port number 3
Step 8
Change IP and Default
gateway according data
fill
Step 3
Click Add Device
Step 9
Click Apply
Step 1
Click OK
Step 3
Select
FPMR(P)
Step 4
Select Mode
according data fill
Step 5
Select enable if ODU
connected to port 3 or 4
Step 6
Select PWR on Integrated
device if ODU connected
to port 3 or 4
Step 1
Select port number 4
Step 7
Change IP and Default
gateway according data
fill
Step 2
Click Add Device
For internal use
Unique document identifier (ID) / Version number / Life cycle status
45
Step 8
Click Apply
Step 1
Click OK
For internal use
Unique document identifier (ID) / Version number / Life cycle status
47
Step 1
Click Device View
Step 2
Select all port
Step 3
Click Configure
System Type
For internal use
Unique document identifier (ID) / Version number / Life cycle status
49
Step 4
Select system type
according data fill
click apply
Step 1
Click OK
Step 3
Select according
data fill
Step 1
Select all port
Step 2
Click Add LPG
Step 4
Click Apply
Step 1
Click Yes
For internal use
Unique document identifier (ID) / Version number / Life cycle status
53
Step 1
Click OK
For internal use
Unique document identifier (ID) / Version number / Life cycle status
55
Step 3
Click Network
Step 4
Click Apply
Step 1
Select all port
Step 2
Click Configuration
Step 1
Click SyncE
Step 4
Select SyncE setting
according data fill
Step 5
Click Apply
Step 2
Select Fixed
Step 1
Click ACM
Step 2
Select ACM TX
profile according
data fill
Step 3
Select TX profile
according data fill
Step 4
Click Apply
Step 2
Select ATPC enable
according data fill
Step 1
Click ATPC
Step 3
Select TX power
according link budget
Step 4
Click Apply
Step 2
Fill in TX and RX according
link budget
Step 1
Click RF
Step 3
Select Channel
bandwidth according
data fill
Step 4
Click Apply & Close
Step 1
Test View
Step 2
Select port 3 & 4
Step 3
Click Apply & Close
Step 1
Login from public IP
Step 1
Click Tetap Unduh
Step 2
Click Run
Step 1
Checked
Step 1
Type sysmanager
Step 2
Click Login
Step 1
Click Device
Step 4
Change to be UNI
Step 5
Change Admin status to
be UP
Step 6
Click Apply
Step 3
Change MTU from
1632 to 1548
74
Step 2
Click Port 2 (Node B)
Step 2
Click Management
VLAN Interfaces
Step 3
Short port IDU 2
Step 1
Click NE Management
Step
Click
5
YES
Step
Click
4
Delete
Step 3
Click Configuration
Step 2
Click LLDP
Step 4
Short port IDU 2
Step 1
Click Ethernet
Configuration
Step 5
Click Disabled
Step 2
Click Service View
Step 1
Click Service Management
Step 3
Click Create
Step 1
Click LPG1 and Port IDU 2
Step 2
Click Next
Step 1
Click Advanced Mode
Step 2
Click E-Line
Step 3
Type 3G in
Service Name
Step 5
Click YES for Multi - CoS
Step 4
Insert VLAN ID 3G
according data fill
Step 6
Click Per Service for
Bandwidth Profile Mode
Step 7
Click Next
Step 2
Insert CE VLAN ID
according data fill
Step 3
Click Add
Step 1
Click Tagged
Step 4
Click Next
Step 1
Select Priority 5
Step 2
Click Next
Step 1
Click Next
Step 1
Click apply
Step 1
Click Close
Step 1
Click Bandwidth Profile
Step 3
Insert CIR according
data fill and one step up
Step 4
Insert PIR according
data fill and one step up
Step 5
Click Apply
Step 2
Click Create
CREATE SERVICES E1
Step 1
Click Device
Step 2
Click Port 16 E1/ T1
Step 3
Chose E1
according data fill
Step 8
Click Refresh
Step 4
Chose E1 for Line type
Step 6
Chose UP
Step 7
Chose Apply
Step 5
Chose 120 ohm for
Line Impedance
Note : repeat to
turn the other E1
For internal use
Unique document identifier (ID) / Version number / Life cycle status
87
Step 2
Click Service View
Step 1
Click Service Management
Step 3
Click Create
Step 1
Click LPG1 and Port
IDU-A CES / ToP
Step 2
Click Next
Step 1
Click Advanced Mode
Step 2
Click E-Line
Step 3
Type 2G in
Service Name
Step 4
Change Global ID
Step 5
Insert VLAN ID 2G
according data fill
Step 6
Click Next
Step 1
Click Next
Step 1
Select Priority 6
Step 2
Click Next
Step 1
Click Next
Step 1
Click Apply
Step 1
Click Close
Step 2
Click CES Service
Step 3
Click Create
Step 1
Click Service
Management
Step 1
Click Advanced Mode
Step 2
Click
CESoP
Step 3
Chose IDU-A PDH
according data fill
Step 4
Insert CE VALN ID
according data fill
Note :
Only change port IDU PDH and click
Add for turn on another E1.
Click Next
For internal use
Unique document identifier (ID) / Version number / Life cycle status
97
Step 5
Click Add
Step 1
Click Next
Step 1
Click Add
Step 2
Click Next
Step 1
Short line
Step 2
Click Next
Step 2
Type IP Source
Address as data fill
Step 1
Type E1 as data fill
Step 3
Type IP Destination
Address as data fill
Step 4
Click Next
Step 1
Click Apply
Step 1
Click Close
Thank You!