Académique Documents
Professionnel Documents
Culture Documents
Page 1
No part of this document may be reproduced or transmitted in any form or by any means, including photocopying and
recording
without the written permission of Siemens Industrial Turbomachinery AB
SGT-800
E O IP
Contents
Main features, benefits and experience
Performance characteristics
Package design
Core engine design
Maintenance
Reference sites
Page 2
SGT-800
E O IP
SGT-800
E O IP
SGT-800
E O IP
Page 5
SGT-800
E O IP
Features
Resulting in
Reliable operation
Predictable service costs
Page 6
SGT-800
E O IP
= 1999
= 131
> 1,300,000
> 70,000
Fleet Availability
98.2%*
Fleet Reliability
99.8%*
Worldwide Sales
Page 7
Sales by Application
SGT-800
E O IP
1 turbine
2 turbines
3-4 turbines
5-9 turbines
10+ turbines
Page 8
SGT-800
E O IP
Contents
Main features, benefits and experience
Performance characteristics
Package design
Core engine design
Maintenance
Reference sites
Page 16
SGT-800
E O IP
Page 17
47 000 kW
9 597 kJ/kWh / 9096 Btu/kWh
37.5 %
131.5 kg/s
/ 289.9 lb/s
544 C
/ 1,011 F
SGT-800
E O IP
Fuel
50-100% load
NOx @ 15% O2
50-100% load
CO @ 15% O2
Note
Gas burner
Natural gas
15 ppmv
5 ppmv
Dry
Dual fuel
burner
Natural gas
15 ppmv
5 ppmv
Dry
Diesel No.2
42 ppmv
5 ppmv
Dry
Page 18
SGT-800
E O IP
SGT-800-47 Nominal Generator Output and Heat Rate for gas fuel
55
10.5
10.4
10.3
10.2
45
10.1
10
40
9.9
9.8
35
Generator Output, MW
50
9.7
9.5
-40
-30
-20
-10
10
20
30
Fuel quality/type
Temperature
Altitude
Atmospheric pressure
9.6
30
40
600
145
590
140
580
135
570
130
560
125
550
120
540
115
530
110
520
105
Exhaust Temperature, C
SGT-800-47 Nominal Exhaust Mass Flow and temperature for gas fuel
150
510
-40
-30
-20
-10
10
20
30
40
Page 19
SGT-800
E O IP
11.2 % losses
1-pressure HRSG
Gas Turbine
37.2 % electricity
100 % fuel
Total Efficiency 88.8 %
Page 20
SGT-800
E O IP
11.6 %
losses
520 deg C
2-pressure HRSG
31 deg C
17.2 %
electricity
31 deg C
Gas Turbine
15 deg C
37.1 %
electricity
27 deg C
100 % fuel
34.1 %
losses
SGT-800
E O IP
SGT-800
125
75
50
m
tea
s
d
Fire
SGT-400
100
SGT-700
Unfired
Fired
SGT-600
150
SGT-500
175
SGT-100
SGT-200
SGT-300
200
ing
s
i
ra
ising
a
r
m
stea
d
e
r
i
f
Un
25
0
0
10
15
20
25
30
35
40
45
50
Power (MWe)
Notes:
1. Steam values are indicative only. Actual values depend on site configuration
2. Firing to 850C only. Higher firing is available
Page 22
SGT-800
E O IP
46 000 kWe
ST
21 400 kWe
Auxiliaries
SCC-800 1x1
-900 kWe
Net total
66 500 kWe
Fuel
El. Efficiency
53.7
at ISO-conditions including losses
Page 23
SGT-800
E O IP
SCC-800 2x1
92 100 kWe
44 400 kWe
-1 400 kWe
Net total
Fuel
El. Efficiency
Page 24
SGT-800
E O IP
Efficiency, %
55
50
45
40
35
50
60
70
Base Load Power, %
80
90
100
Condensing operation
Non - reheat, 1 x SGT-800
Natural gas fuel
Page 25
= 60 %
SGT-800
E O IP
Contents
Main features, benefits and experience
Performance characteristics
Package design
Core engine design
Maintenance
Reference sites
Page 26
SGT-800
E O IP
Combustion air
inlet filter
Exhaust
Enclosure
ventilation inlet
Enclosure
ventilation outlet
Fire suppression
cabinet
AC generator
Generator cooling
air inlet
Electrical and
Control module
Page 27
SGT-800
Generator air
outlet
E O IP
Page 28
SGT-800
E O IP
Page 29
SGT-800
E O IP
Contents
Main features, benefits and experience
Performance characteristics
Package design
Core engine design
Maintenance
Reference sites
Page 30
SGT-800
E O IP
15 stage compressor
3 stages variable guide vanes
Bearing #2 (radial)
3 stage turbine
6600 rpm
Page 31
SGT-800
E O IP
Contents
Main features, benefits and experience
Performance characteristics
Package design
Core engine design
Maintenance
Reference sites
Page 32
SGT-800
E O IP
Page 33
SGT-800
E O IP
Level "D"
Level "C"
Level "B"
Level "A"
Operation
Maintenance
10
20
30
40
50
60
70
80
90
100
110
120
Page 34
SGT-800
E O IP
Page 35
SGT-800
E O IP
Emergency back-up
24-hour telephone
support
Operation support
24/7 emergency phone
On-line remote troubleshooting
Remote Monitoring System
Emergency
gas generator
Emergency resources
Service engineers
Tools & spare parts
Core engine & modules
Service depots
Emergency store
Guaranteed mobilization time
Personnel - 24 hours
Tools, spares, engine & modules to site or to
international freight forwarder within 72 hours
Page 36
SGT-800
E O IP
Data collection
Decision Support
Reporting
Plant Data:
Operational Data
Customer
Closed Loop
Service
Risk Mitigation
O&M support
Solutions /
Improvements
Trouble shooting
Page 37
SGT-800
Diagnostics Experts
Team
FLEET INPUT
E O IP
SGT-800
E O IP
Contents
Main features, benefits and experience
Performance characteristics
Package design
Core engine design
Maintenance
Reference sites
Page 39
SGT-800
E O IP
Riga, Latvia
Combined heat and power plant
supplying electricity and district heating
for the city of Riga. Owned by
Latvenergo, the Latvian national
electricity company
Turn key delivery from Siemens including
two SGT-800's, steam turbine, two
supplementary fired HRSG, auxiliaries
and balance of plant
Handed over to customer on schedule
2005
Nominal power output 140 MW and up
to 150 MWth for district heating
DLE combustors operating on natural gas
Page 40
SGT-800
E O IP
Page 41
SGT-800
E O IP
Compact layout
Page 43
SGT-800
E O IP
Disclaimer
This document contains forward-looking statements and information that is, statements related to future, not past,
events. These statements may be identified either orally or in writing by words as expects, anticipates, intends,
plans, believes, seeks, estimates, will or words of similar meaning. Such statements are based on our current
expectations and certain assumptions, and are, therefore, subject to certain risks and uncertainties. A variety of factors,
many of which are beyond Siemens control, affect its operations, performance, business strategy and results and could
cause the actual results, performance or achievements of Siemens worldwide to be materially different from any future
results, performance or achievements that may be expressed or implied by such forward-looking statements. For us,
particular uncertainties arise, among others, from changes in general economic and business conditions, changes in
currency exchange rates and interest rates, introduction of competing products or technologies by other companies, lack
of acceptance of new products or services by customers targeted by Siemens worldwide, changes in business strategy
and various other factors. More detailed information about certain of these factors is contained in Siemens filings with the
SEC, which are available on the Siemens website, www.siemens.com and on the SECs website, www.sec.gov. Should
one or more of these risks or uncertainties materialize, or should underlying assumptions prove incorrect, actual results
may vary materially from those described in the relevant forward-looking statement as anticipated, believed, estimated,
expected, intended, planned or projected. Siemens does not intend or assume any obligation to update or revise these
forward-looking statements in light of developments which differ from those anticipated.
Trademarks mentioned in this document are the property of Siemens AG, it's affiliates or their respective owners.
Page 44
SGT-800
E O IP
SGT-800
E O IP