Calibration

BUT45
Sensors

BUT45 Sensor calibration


Preparation
Required tools
Digital spirit level
Tape measure
Sight plates

BUT45 Sensor calibration


Step 1
Calibrate rig inclination sensor
1. Level rig with digital spirit level and set to zero
2. Measure and check that it matches with screen

BUT45 Sensor calibration


Step 2

Check the feed holder distance


1. Position feed beam to rear position
2. Measure and check that it matches with screen

1.

2.

BUT45 Sensor calibration


Step 3
Calibrate boom extension
Retract boom extension and set to zero in menu
Extend boom and measure, should match value on display

BUT45 Sensor calibration


Step 4
Calibrate feed extension
Retract feed extension fully and set to zero
Extend feed extension and check that the value on the screen is 1.8m

BUT45 Sensor calibration


Step 5
Calibrate feed rotation
Make sure the rig is in level
Position feedbeam on top of the boom and measure on the two measuring
points

Set to zero

BUT45 Sensor calibration


Set coefficient / Boom Swing
Set coefficient for Boom Swing
Increasing angle

Decreasing angle

BUT45 Sensor calibration


Set coefficient / Boom Lift
Set coefficient for Boom Lift
Decreasing angle

Increasing angle

BUT45 Sensor calibration


Set coefficient / Feed tilt
Set coefficient for Feed Tilt

Decreasing angle

Increasing angle

BUT45 Sensor calibration


Set coefficient / Feed swing
Set coefficient for Feed Swing
Increasing angle

Decreasing angle

BUT45 Sensor calibration


Laser calibration
Mount the sight plates onto the feed

BUT45 Sensor calibration


Laser calibration
Aim the rig laser trough the sight plates and push
Calibrate sensors compared to laser