Vous êtes sur la page 1sur 156

Magnetic Particle

Level II
(CGSB 48-9712)

1. Principles of Magnets and Magnetic


Fields
Theory of magnetic fields - Magnetic
domains

Materials that can be magnetized have submicroscopic regions called magnetic


domains that will have positive and negative polarity at opposite ends if
magnetized.
If a material is not magnetized, the magnetic domains are randomly orientated.
When the material is subjected to an indirectly induced magnetic external field
or if current is passed directly through the test object, the magnetic domains
align themselves and form a north and south pole in the test object.

1. Principles of Magnets and Magnetic


Fields
Theory of magnetic fields - Earth's magnetic field

The Earth's magnetic field resembles that of an enormous bar magnet. The field
lines emerge from the southern half of the earth and re-enter in the northern half.
The earth's magnetic field serves to deflect most of the solar wind, whose charged
particles would otherwise strip away the ozone layer that protects the Earth from
harmful ultraviolet radiation.

1. Principles of Magnets and Magnetic


Fields
Theory of magnetic fields - Magnets

Lodestone is a naturally magnetized piece of the


mineral magnetite; is black or brownish-black with a
metallic luster..
Lodestone

Man-made magnets are made from a material that is


strongly attracted to a magnet, are called ferromagnetic
(or ferrimagnetic) material - including iron, nickel, cobalt
and some rare earth metals. Neodymium magnets,
(1980s, strongest & affordable rare-earth magnet). alloy
of neodymium, iron and boron (Nd2Fe14B). Uses compact permanent magnets for electric motors for
cordless tools, hard drives, and magnetic hold-downs
and jewelry clasps

Rare earth metal

Electro-magnet are induced by passing current thru the


object or equipment. For example an AC yoke is an
electro-magnet used for MPI.
AC Yoke

1. Principles of Magnets and Magnetic


Fields
Theory of magnetic fields

Magnetic field around magnetised material is


invisible to the naked eye.
But the field can be visualise with iron filing as
shown below. The pictures below show the
different flux pattern. Magnetic flux is the lines of
forces.

Magnetic lines of force


around a bar magnet

Opposite poles
attracting

Similar poles repelling

1. Principles of Magnets and Magnetic


Fields
Theory of magnetic fields
-

Magnetic lines of force present in a magnetic field are


called the magnetic flux. The unit of magnetic force is the
Maxwell.
Flux density is the flux per unit area ("B"). The unit of flux
measurement is the Gauss.
Surface flux strength; flux can flow on the surface and in
AC magnetization will concentrate on the surface (skin
effect) ; whereas DC magnetization will be more distributed
throughout.

AC

DC

Johann Carl Friedrich Gauss (30 April 1777 23 February 1855) German mathematician/physicist.
James Clerk Maxwell (June 13, 1831 - November 5, 1879) Scottish physicist

1. Principles of Magnets and Magnetic


Fields
Theory of magnetism

Magnetic poles : bar and horseshoe magnet

Ring magnet with


poles

Bar magnet with


poles
Horseshoe magnet
with poles

1. Principles of Magnets and Magnetic


Fields
Theory of magnetism

Laws of magnetism
- Like poles repel
- Unlike pole attract

1. Principles of Magnets and Magnetic


Fields
Theory of magnetism

Material influenced by magnetic field (ferro/para/dia-magnetic).

Diamagnetic - Those materials that are feebly repelled by a strong magnet. Small
and negative susceptibility to magnetization. Eg Copper, Silver, Gold.

Paramagnetic - Those materials that will accept magnetism but only slightly. Small
and positive susceptibility to magnetization. Eg. Magnesium, Lithium, Tantalum

Ferromagnetic- Those materials that can be strongly magnetized and are suitable
for magnetic particle inspection. Large and positive susceptibility to magnetization.
Eg, Iron, Nickel, Cobalt

Ferromagnetic material have strong attraction and are able to retain magnetisation
after the magnetizing field is removed; especially hard or tool steel.

1. Principles of Magnets and Magnetic


Fields
Theory of magnetism

Distance factors
- The further from the poles the weaker is the field

1. Principles of Magnets and Magnetic


Fields
Theory of magnetism

Magnetic lines of force (flux) have the following characteristics:


- They form closed loops.
- They resemble rubber bands in that they will stretch and change shape under the
influence of any magnetic fields present.
- They return upon themselves and form close paths.
- They never cross.
- They seek the path of least resistance.
- They are most densely packed at the poles.
- They flow from north to south outside of the magnet and from south to north inside
the ferromagnetic material.

1. Principles of Magnets and Magnetic


Fields
Theory of magnetism

Phenomenon action at discontinuity


If a ferromagnetic test specimen is magnetized with a strong magnetic field created by
a magnet or special equipment. If the specimen has a discontinuity, the discontinuity
will interrupt the magnetic field flowing through the specimen and a leakage field will
occur.

1. Principles of Magnets and Magnetic


Fields
Theory of magnetism

Heat effects on magnetism


- The Curie temperature is the critical point where a material's intrinsic magnetic
moments change direction hence loses its magnetism.
- The Curie temperature is named after Pierre Curie who showed that magnetism
was lost at a critical temperature

Material

Curie temp. (F) Curie temp .(C)

Cobalt

2039

1115

Iron (Fe)

1416

770

Fe2O3

1247

675

Nickel

669

354

1. Principles of Magnets and Magnetic


Fields
Theory of magnetism

Material hardness and magnetic retention


- Hard steel (tool steel) are hard to magnetise and de-magnetise; hence
retain magnetism. They are good for making permanent magnets.
- Soft or mild steel is used for fabrication of structures and pressure vessel.
Easy to magnetise and de-magnetise; hence retain little or no residual
magnetism.
Later in the sections on hysteresis loop and de-magnetisation; the hard and
soft steel characteristics will be better defined.

1. Principles of Magnets and Magnetic


Fields
Terminology associated with magnetic particle testing

Magnetic flux : maxwell


Magnetizing force (H) : oersted
Flux density (B) : gauss
Reluctance
Permeability (B/H = )
Coercive force
Residual magnetism
Retentivity
De-magnetization
Hysteresis loop/curve
Flux leakage
Induction
Flash point
Viscosity
Contrast Ratio

Hans Christian rsted (14 August 1777 - 9 March 1851) Danish physicist

2. Characteristics of Magnetic Fields


Bar magnet and ring magnet
Bar magnet has poles (N&S) and
magnetic field outside the bar

Ring magnet has no poles and


magnetic field are all internal

2. Characteristics of Magnetic Fields


Current Type
-

Alternating current (AC) is the most basic source single phase or 3-phase.
A

AA
Single phase

3-phase

Direct current (DC) is either from a stored media (eg batteries, capacitors) or
converted from AC (eg. half-wave DC or full-wave DC)
A

Battery

HWDC

FWDC

2. Characteristics of Magnetic Fields


Alternating Current
Cyclic effects
- Due to cyclic nature of AC, the indication will appear to be dancing (particle
mobility) and hence better delectability.
Surface strength characteristics
- AC will have concentration of the field lines on the surface (skin effect); better
detection of surface or very close to surface discontinuities. Not good for subsurface or deep discontinuities (3-5mm).
Safety precautions
- Caution when using AC; high voltage and amperage
Source of current
- Generator or public utility will produce AC; 120V single phase or 440V 3-phase.
No rectifiers are required so the weight of the equipment is reduce, lighter and less
expensive; AC is also used for demagnetizers

2. Characteristics of Magnetic Fields


Half-wave (Pulsating) Direct Current
-

Derived from AC (single phase) but taking only one half of the wave; hence there is
a pause between each half wave (pulsating)
Good for particle mobility (due to pulsating) and field penetration

2. Characteristics of Magnetic Fields


Direct Current (FWDC)
-

Derived from AC (single phase) but taking both halves of the wave; hence there is
no pause between each half-wave.
Good for field penetration but particle mobility is compromised.

2. Characteristics of Magnetic Fields


Direct Current (FWDC : 3-phase)
-

Using 3-phase AC it is possible to use rectifiers to produce a FWDC that look very
close to pure DC (little ripples). It can be filtered to pure DC as shown below.

2. Characteristics of Magnetic Fields


Relative sensitivity of different methods
-

AC magnetization is most effective for surface defects.


AC magnetization is not effective for subsurface defects.
HWDC is recommended for subsurface defects.
HWDC superior penetration to FWDC.
HWDC dc dry method gives the greatest penetration.

3. Effects of Discontinuities on Materials


Surface and sub-surface discontinuities
Indications
- Anything that is revealed during the inspection
Imperfections
- Any anomalies (deviation from the design or specification)
Discontinuities
- Indications that are flaws (faults); which may or may not acceptable
Defects
- Discontinuity that does not comply to an acceptance criteria or accepted norms.
- It can be detrimental if put in service
When we find something during an inspection, we call it an indication. Then if we can
attribute to be flaw then we call it a discontinuity. If the we compare it to an acceptance
criteria and it exceeds the acceptable limits then we call it a defect.

3. Effects of Discontinuities on Materials


Surface and sub-surface discontinuities
Surface discontinuities
- Discontinuities that are located at or very close to the surface (1-3mm approx.)
Sub-surface discontinuities
- Discontinuities located below the surface (3-5mm approx.); may go deep but then
the indication may be too fuzzy to interpret.

Fuzzy indication
Sharp indication

3. Effects of Discontinuities on Materials


Surface and sub-surface discontinuities

DC flux near and sub-surface


flaws
AC flux surface flaws

3. Effects of Discontinuities on Materials


Design factors
Mechanical properties
- Properties like tensile strength, hardness and toughness will influence how the
material is use in fabrication and hence usage (service)
- Eg. for cold weather application (say below -40oC); a charpy test for toughness is
maybe required.
Part usage
- what is the part use for; how critical is the part?
- Eg. a turbine shaft may use a more sensitive technique such as wet florescent on
the wet bench
Relationship to load-carrying ability
- Is the part design to carry load?
- Eg. a lifting lug will require a critical inspection as it will be used in the lifting of the
component it is attached to may be a weld lug or bolted lug.

Georges A. Charpy (1 September 1865 25 November 1945) French scientist

4. Magnetization by Electric Current


Circular and Longitudinal Field
The two basic magnetic fields are:
- Circular field, and
- Longitudinal field

Faradays right hand rule


- Describe the relation between
current and magnetic field induces
in a wire (part) carrying a current.
If electron flow is used then left hand
rule applies

Michael Faraday (22 September 1791 25 August 1867) English physicist

4. Magnetization by Electric Current


Circular Field
Field around a straight conductor
- Using the right hand rule; the magnetic field around a conductor will be circular and
hence the term circular field.

Circular field

4. Magnetization by Electric Current


Circular Field
Field in parts with current flowing - long, solid regular parts

Head shot
using
contact
plates

4. Magnetization by Electric Current


Circular Field
Field in parts with current flowing - tubular parts

Head shot
using
contact
plates

Head shot using


central
conductor

4. Magnetization by Electric Current


Circular Field
Field in parts with current flowing - irregularly shaped parts (holes/slots)

Head shot
using
contact
plates

Head shot using


central
conductor

4. Magnetization by Electric Current


Circular Field
Methods of inducing field - contact plates (direct)
- Current is passed directly thru the part
- Good contact is critical; if not it may arc (sparking); same if the current is too high

4. Magnetization by Electric Current


Circular Field
Methods of inducing field- prods (direct)
- Using two prods (electrodes) and passing a current thru the part (indirect)
- Good contact is critical; if not it may arc (sparking); or if current is too high.

4. Magnetization by Electric Current


Circular Field
-

Methods of inducing field - central conductors (indirect)


Using a conductor (copper bar), pass through the hollow part and the current flow
to induce the magnetic field
No arcing of part as there is no direct flow of current thru part

4. Magnetization by Electric Current


Circular Field
-

Methods of inducing field - through cables (indirect)


Similar to a central conductor except a cable (wire) is used
Again no arcing of part

4. Magnetization by Electric Current


Circular Field
Methods of inducing field - leeches and clamps (direct)
- Similar to prods, except the contacts are held by magnets or clamps
- Arc is possible if contact is not good or current too high.

Leech

Clamp

4. Magnetization by Electric Current


Circular Field
Discontinuities commonly found by circular fields
- Any discontinuity perpendicular, or at angle but not parallel, to the circular field
- Longitudinal cracks, seam, laps, stringer etc.

4. Magnetization by Electric Current


Circular Field
Discontinuities commonly found by circular fields - examples

4. Magnetization by Electric Current


Circular Field
Current calculations
- Do some samples with the various equations
Direct contact
- Solid round part
- Solid rectangular part
- Solid irregular part
- Hollow part
Central conductor
- Hollow/ring part
- Irregular part
Prods
- Thickness and spacing

4. Magnetization by Electric Current


Circular Field
Direct Current Field Distribution
Solid Non-magnetic Conductor
-

Magnetic field strength varies from


zero in the centre to maximum at
the surface
Field strength outside the conductor
decreases exponentially with
distance

4. Magnetization by Electric Current


Circular Field
Direct Current Field Distribution
Solid Magnetic Conductor
-

Magnetic field strength increase


from zero in the centre to maximum
at the surface with a field strength
greater than a non-magnetic
conductor due to permeability,
Field strength outside the conductor
decreases exponentially with
distance; same as the non-magnetic
conductor

4. Magnetization by Electric Current


Circular Field
Direct Current Field Distribution
Hollow Non-magnetic Conductor
-

Magnetic field strength increase


from zero inside surface to
maximum at the surface
Field strength outside the conductor
decreases exponentially with
distance

4. Magnetization by Electric Current


Circular Field
Direct Current Field Distribution
Hollow Magnetic Conductor
-

Magnetic field strength increase


from zero in the centre slowly to
inside surface then rapidly to
maximum at the surface with a field
strength greater than a nonmagnetic conductor due to
permeability,
Field strength outside the conductor
decreases exponentially with
distance

4. Magnetization by Electric Current


Circular Field
Direct Current Field Distribution
Hollow Part with Central Conductor
-

Magnetic field strength is strongest


on the inside of magnetic hollow
part and decrease slightly at the
outside surface (good for ID
discontinuities),
Field strength outside the conductor
decreases exponentially with
distance

4. Magnetization by Electric Current


Circular Field
DC Field Distribution vs AC Field Distribution
-

DC increase is even
AC the increase slow then rapid
AC field concentrated near the surface
AC has skin effect (good for surface
discontinuities),
Field strength outside the conductor
decreases exponentially with distance

4. Magnetization by Electric Current


Circular Field
Safety precautions
- Ensure good contact; clean contacts
- Do not over-amp (too high current)
- Will prevent arcing (sparking) and over-heating
Advantages of circular field
- Fast and good coverage; one shot will be good for whole part
- High amperage; good penetration for sub-surface discontinuities (using DC)
Disadvantages of circular field
- High amperage; safety precautions from electrocution
- Good contact and not too high amperage; arcing and over-heating. Never burn a
inspected part
- Not good for transverse orientated discontinuities (ie. parallel to field)

4. Magnetization by Electric Current


Longitudinal Field
-

Field produced by current flowing in a coil


Coil of a few turns (3-7); use to create a longitudinal field
Each turn will produce individual circular filed but combining the adjacent circular
field a longitudinal field is created.

4. Magnetization by Electric Current


Longitudinal Field
Principles of inducing flux
- The way magnetic field is induced is dependent on part geometry (and size), coil
shape and size.
- For example a wet bench coil is usually 10-14 in diameter; so the parts are limited
to anything less than the coil diameter. If the part is longer than 15 (approx.), then
more than 2 coil shots have to be performed.
- A yoke has the coil (solenoid) external to part and the induced magnetic field flow
into the part much like a horse-shoe magnet.

4. Magnetization by Electric Current


Longitudinal Field
Use of coils, cables and yokes
Stationary coil

Portable coil

Wrapped coil

Yoke

4. Magnetization by Electric Current


Longitudinal Field
Current calculations - do samples with the various equations
- L/D ratio
- Number of turns
- Fill factor & placement (inside edge / middle of coil)
- Part length
- Use of extensions
(for coil stationary, portable and wrapped)
Yoke AC & DC
- Do not need calculation as amperage is note on unit (say 4Amps)
- Orientation is critical in yoke

4. Magnetization by Electric Current


Longitudinal Field
Quick break & transient (eddy) current
Quick break (fast break or controlled break) is the sudden ending or stopping of
magnetizing current. This breaking of the current results in a transient (eddy)
current induced into the part..
- When a direct current is shut off, the field around the conductor falls rapidly to
zero. This rapid change of energy generates a voltage and a current that is in the
opposite direction of that in the circuit resulting in a transient current being induced
into the part.
- The resulting current was greatly increased when using quick break on
ferromagnetic material; hence and increase in the residual magnetic field inside of
the part resulted in a better field for inspection for finding transverse discontinuities
in the ends of longitudinally magnetized bars.
- These types of discontinuities are often concealed by the strong polarity at the bar
ends.
- With the use of the quick break technique, the resultant transient current makes
certain that the field stays true to the end of the bar, enabling the inspection of
transverse discontinuities.

4. Magnetization by Electric Current


Longitudinal Field
Quick break & transient (eddy) current
very ends of bar are not truly longitudinally
magnetized and any transverse indications
in this area may not be reliably detected

Residual field n bar


generated by slow break

transient current generated flows inside the bar


resulting in a near surface field, allowing part to
be truly longitudinally magnetized to the very
ends of the bar; hence allowing
transverse indications to be found at the very
end of bar

Residual field n bar


generated by quick break

4. Magnetization by Electric Current


Longitudinal Field

Advantages
- No direct induction so no arcing (sparking)
- Good for circumferential or transverse discontinuities
- Good portability (yoke)
Disadvantages
- Not good for longitudinal discontinuities (ie. parallel to field)
- For long part (more 15-18) need more than 1 shot for coverage.

4. Magnetization by Electric Current


Multi-directional magnetization
Combination of shots that will be used to inspect a part in one or two steps; usually
without re-positioning of the part. Eg. swinging field technique
- The two basic flux directions is achieved by the use of two phases of a three phase
mains supply.
- One phase is connected to the longitudinal flux generating system which can be
either a coil or a flux flow system. A second phase is used to generate
circumferential flux, usually by current flow through the work piece.
- As there is in sinusoidal A.C. a cyclic change in current value from zero to
maximum positive, down to zero, on to maximum negative and return to zero - fifty
times per second, and as there is a lag between the two phases, at any instant
there will be different amplitudes of longitudinal and circumferential fields.

4. Magnetization by Electric Current


Multi-directional magnetization
Swinging field (Approach 1) :
solid part
-

Direct contact
Coil

4. Magnetization by Electric Current


Multi-directional magnetization
Swinging field (Approach 2) :
hollow part
-

In-direct contact (central


conductor
Coil

4. Magnetization by Electric Current


Toroidal magnetization
-

toroid is a doughnut shaped object


purpose of using toroidal magnetization is to create a noncontact type of magnetic
induction to eliminate the possibility of arc burning that may be produced by a direct
contact shot
performed in one step compared with other methods that might require multiple
inspection steps, because the magnetic field is uniform and completely
encompasses the part (assuming uniform part geometry)

4. Magnetization by Electric Current


Toroidal magnetization
Primary effect - magnetizing current (mag shot) produces a field surrounding the part
Secondary effect - circumferential current flow is developed within the test piece by the
collapsing field.
Tertiary effect - strong toroidal magnetic field is created as a product of the secondary
current flow within the part.
Discontinuities perpendicular to the field direction within the part may now be detected.

Secondary
current
is
induced in ring only as
result of movement of
magnetic
field
of
bar
magnet in relationship to
ring. Induced current in ring
creates toroidal field (blue
line)

4. Magnetization by Electric Current


Toroidal magnetization
Use coil on a wet horizontal and a high permeability, low retentivity ferromagnetic
laminated core through part to concentrate the flux and make it perform more efficiently.
When coil is energized, a longitudinal field flows the laminated core and to some extent
in part.
When coil is de-energized, this field collapses and induces a circumferential current into
part. This in turn induces a strong toroidal field surrounding the part in a radial direction

Magnetic flux during


magnetizing pulse is
concentrated in core
inserted through test
object

4. Magnetization by Electric Current


Toroidal magnetization
Use a tabletop transformer fixture connected to the wet horizontal machine or portable
MT machine using a standard clamp block
wet continuous method can be use and be removed from the machine when not
needed

Table top, closed loop


transformer fixture showing
close proximity of primary and
secondary (ring shaped test
object) windings with core

4. Magnetization by Electric Current


Multi-directional magnetization
Magnetic field adequacy and direction
When it is necessary to verify the adequacy of magnetic field strength (and direction),
one of the following may be used
- Magnetic field indicator (pie-gage)
- Artificial shims (QQI); castrol strips; magnetic card
- Hall effect tangential field probes

4. Magnetization by Electric Current


Multi-directional magnetization
Magnetic field adequacy and direction
Castrol strips
Pie gage

Shims (QQI)
Hall effect
meter

4. Magnetization by Electric Current


Multi-directional magnetization
Hall effect meter

4. Magnetization by Electric Current


Multi-directional magnetization
Hall effect meter eg measure field in bolt hole

5. Selection proper method of


magnetization
Factors determining the selection

Alloy, shape and condition of part


Type of magnetizing current
Direction of magnetic field
Sequence of operations
Flux value (hall effect gauss meter)

Examples:- Weld
- Shaft/bolt
- Small casting (landing gear)
- Large casting (bonnet)

6. Inspection materials
Inspection particles
The magnetic particles used for MPI is essentially iron fillings with a dye (make it more
visible): - Wet particles: suspended in a liquid (vehicle or media)
- Dry particles (powder): just particles and dye.
They can be visible and florescent magnetic particles:- Visible particles are used for visible MPI with white (normal) light
- Florescent particles for use with UV or black-light
Characteristics of magnetic particle:- High permeability (low retentivity)
- Size and shape for consistent results
- Non-toxic
- Free form contaminants (dirt, grease, rust etc.)

6. Inspection materials
Liquids (Suspensions) and Powders
Dry particles (powder)
- Assortment of color (depending on the background); grey, black, red, yellow, blue
- Use as supplied; spraying or dusting
- Not affect by cold and heat resistant (upto 600oF/315oC)
- Good for detection of near surface flaws
- Portable equipment on large surfaces (large castings)
- Superior particle mobility
- Easy to remove (falls off)

6. Inspection materials
Liquids (Suspensions) and Powders
Dry particles (powder)
- Large size (#8A red 180microns); less sensitive than wet florescent.
- Not use in confined space without safety breathing apparatus
- Difficult for overhead positions
- Does not leave evidence of coverage
- Low production than wet florescent
- Difficult to adapt to any automatic system

6. Inspection materials
Contrast and background
Contrast
- state of being strikingly different from something else, typically something in close
association
- dye makes an indication more visible to the human eye
- different colored dyes; blue, yellow, and green, but it seemed that the red dye
resulted in best response to visible observation
- term "contrast ratio" is generally used to express "seeability"
- white dye on a white background, the contrast ratio would be one-to-one; no
contrast between the dye and the background.
- red dye, the contrast ratio is said to be six-to-one, making that contrast very
noticeable on a white background surface
- contrast ratio of a fluorescent dye is said to be forty-to-one
- hence, fluorescent penetrant produces a much higher degree of "seeability" or
sensitivity as compared to visible dye penetrants

6. Inspection materials
Liquids (Suspensions) and Powders
Particles in suspension:- particles suspended in a vehicle such as water or light petroleum distillate applied
by flowing. spraying. or pouring
- available in both fluorescent and non-fluorescent concentrates
- premixed with suspending vehicle by the supplier. but usually supplied as dry
concentrate (powder) or paste concentrate (to be mixed by the user)
- suspensions normally used in wet horizontal MPI equipment; dispensed from an
aerosol or other dispensers
Liquid requirements as vehicle/media
- wetability; good wetting for surface of parts
- viscosity about 5 mm2/s (5 centistokes) at room temperature; good particle
mobility.
- flammability; flashpoint of 57oC (135oF) are lowest practical flammability threshold
- odor; not objectionable and no (little) undesirable contaminants (sulfur)
- fluorescence; because most wet suspensions use fluorescent particles and many
oils are also naturally fluorescent, an
- oil with a low level of natural fluorescence is desirable
- non-toxic and does not damage part (eg sulphur, halogen)

6. Inspection materials
Liquids (Suspensions) and Powders
Using water as vehicle/media:- not flammable
- easily available; cheap
- suitable conditioning agents are added which provide proper wet dispersing
(wetability)
- corrosion protection (corrosion inhibitor) for parts being examined and the
equipment used
- disperse the magnetic particles without evidence of particle agglomeration.
- minimize foaming; it should not produce excessive foam which would interfere with
indication formation or cause particles to form scum with the foam
- conditioned water should be essentially odorless (use germicide)

6. Inspection materials
Liquids (Suspensions) and Powders
Using oil or petrol distillate as vehicle/media:- significant advantages for the use of petroleum distillate vehicles the magnetic
particles are suspended and dispersed in petroleum distillate vehicles without use
of conditioning agents (good wettability)
- petroleum distillate vehicles provide a measure of corrosion protection to part and
the equipment used
- disadvantages are flammability. fumes. and availability
- select and maintain readily available sources of supply of petroleum distillate
vehicles that have as high a flash point as practicable
- work area with proper ventilation

Product Name: BAYOL 35


Product Description:
lsoparaffinic
Hydrocarbon
Intended Use: Solvent

6. Inspection materials
Liquids (Suspensions) and Powders
Advantages of suspension:- small size (7C black: 20microns; 14A: 6microns); more sensitive than dry powder
- able to remain in discontinuities until they are removed
- contrast is invariably higher with wet fluorescent
Disadvantages of suspension
- Hard to remove; oil remnant not good for processes (eg. welding)
- Handling procedures; especially with flammable liquid (petroleum distillate)
- Mixing suspension; additives for water vehicle
- Odor and ventilation requirements

6. Inspection materials
Liquids (Suspensions) and Powders
Mixing procedures for suspension
- pour water or light oil distillate into a container or tank
- weigh or measure the required concentrate
- pour concentrate into the container or tank; stir as required
- take a sample and measure the concentration with centrifuge tube

14A concentrate :

1/6 oz./gal. (1.25 g/l)


0.15 - 0.28 ml/100ml

7C concentrate :

1.25 oz/gal (9.4 g/l)


1.3 1.7ml/100ml

Note: use of a reference concentration when new suspension is mixed

6. Inspection materials
Liquids (Suspensions) and Powders
Stationary equipment with circulating bath/suspension
trough

6. Inspection materials
Liquids (Suspensions) and Powders
Mixing suspension - accurate proportions
- Visible : 1.2 to 2.4ml/100ml
- Florescent: 0.1 to 0.4ml/100ml

6. Inspection materials
Liquids (Suspensions) and Powders
Centrifuge tubes
- Visible : with 1.5ml stem
- Florescent: with 1.0ml stem

florescent

visible

7. Principles of Demagnetization
Hysteresis loop/curve
-

magnetic hysteresis loop or curve is a graph that plots magnetizing force and
magnetic field strength
use magnetising and de-magnetising procedures

7. Principles of Demagnetization
Hysteresis loop/curve
Permeability:

7. Principles of Demagnetization
Hysteresis loop/curve

Permeability - ease with which a magnetic flux is established in a part


Reluctance - opposition of a magnetic material to establish a magnetic flux
Residual magnetism - amount of magnetism remaining after the
magnetising force is removed
Retentivity - ability of material to retain residual magnetism
Coercive force - the reversing magnetising force required to remove the
residual magnetism in a part

7. Principles of Demagnetization
Hysteresis loop/curve

Soft steel:- Thin hysteresis loop


- High permeability
- Low reluctance
- Low coercive force
- Low residual magnetic field
- Low retentivity

Hard steel:- Wide hysteresis loop


- Low permeability
- High reluctance
- High coercive force
- High residual magnetic field
- High retentivity

7. Principles of Demagnetization
Residual magnetism
When the magnetising current is removed not all the magnetic field is removed (see
hysteresis loop/curve)
- Same direction and weaker than the magnetic field
- A stronger magnetic field will overcome a weaker one (useful when de-mag circ
field)
Reasons for requiring demagnetization
- Affect magnetic compass (navigation) and delicate instruments
- Attract metal (shavings, chips) causing wear or binding
- May cause arc blow deflect molten metal in DC welding
- Magnetic particles may not be removed and hence cause problem later

7. Principles of Demagnetization
Residual magnetism
Residual magnetism can be measured using
- Gaussmeter (magnometer)
- Hall effect gaussmeter (fieldmeter)

Gaussmeter

Hall effect meter

7. Principles of Demagnetization
Residual magnetism
Longitudinal and circular residual fields
- Difficult to judge if a circular field is de-mag as it is difficult o measure as the flux
lines does not leave the part (unlike longitudinal field)
- So a circularly magnetised part should be long mag (stronger field) before demagnetising
To demagnetise a part that has been longitudinally magnetised
- use the reduce and reverse method
Reversing the magnetic field
- Reverse part in the magnetic field
- Reverse the current through the coil
- Reversing the coil (flip it by 180o)
Reducing the magnetic field
- Reduce the magnetising current
- Move the part away from magnetic field (coil)
- Move the coil away from the part
Any combination of the above maybe used.

7. Principles of Demagnetization
Methods of demagnetization
AC Coil Method
- AC flows in one direction (-) and then the opposite direction (+)
- at every cycle the current is reduced
- that means the current is reversing (AC) and reducing with each cycle
- If coil does not have a reducing current rheostat; pull part way from the coil

7. Principles of Demagnetization
Methods of demagnetization
DC Coil Method
- DC does not flow in like AC, so to reverse the direction it has to be done
mechanically (ie reverse the DC current or flip the part)
- reduce first then reverse
- at least 10 reversals but not more than 30 (1 reversal per second)
- DC de-magnetisation is more penetrating than AC; better for large part
Part that have been de-magnetised should be stored in the East-West direction; so
that it does not pick up the earths field.
The amount of residual that is allowed in a prat dependents on the specification. At
times the residual may not reach zero,. For instance in some specification the
maximum allowed residual may be 3 gauss.
If a part is to be heat treated (say pass the Curie temperature); demagnetisation may
not be required.

7. Principles of Demagnetization
Methods of demagnetization
AC Yoke Method
- With AC yoke move the yoke away from the part while the current is on

8. Magnetic particle testing equipment


Equipment-selection considerations
Type of magnetizing current
- AC (single phase): yoke, portable unit, prods
- AC (3-phase): stationary unit (wet bench), multi-directional units
- DC battery: yoke (battery powered)
Location and nature of test
- In-situ (on-site): yoke or portable units
- Small objects and/or movable
Test materials used
- Weldments: yoke, prods
- Aircraft parts: bench, yoke, portable units
-

Purpose/area of test
Spot inspection and small area: yoke
Whole casting, full exam: bench or multi-directional unit

8. Magnetic particle testing equipment


Manual inspection equipment
Portable yoke, portable MPI machine (with prods, clamps, coil)

Reason(s) for portable equipment


- do inspection in-situ (on-site) or remote location (eg. off-shore); ie. part cannot be
move to lab or test center
- do a quick job with little set-up; like yoke
Capabilities of portable equipment
- similarity to stationary equipment; AC/DC; circular/longitudinal fields

8. Magnetic particle testing equipment


Manual inspection equipment
Stationary bench, multi-directional units

should be capable of handling large and heavy parts with cranes or forrklift
flexibility in use; both circular and longitudinal field or both
need for stationary equipment; better coverage; penetration (DC); efficient on large
repeat quantities; better sensitivity with wet florescent
use of accessories/attachments; coils, central conductor with black light for greater
sensitivity

8. Magnetic particle testing equipment


Mechanized inspection equipment
Semi-automatic inspection equipment
- Single-purpose semi-automatic equipment; like inspection of small specific item (eg
automotive part knuckle: Karl Deutsch NDT)

- Multi-purpose semi-automatic equipment; flexible re-tooling for different geometries

8. Magnetic particle testing equipment


Black light equipment
Electro-magnetic wave spectrum and ultra-violet (black-light invisible) wave

8. Magnetic particle testing equipment


Black light equipment

8. Magnetic particle testing equipment


Black light equipment
Black light and fluorescence
-

fluorescence is ability of some chemical


compounds to emit visible light when exposed to
near ultraviolet radiation
color of the emitted light depends upon the
material
most frequently used dyes emit a yellow-green
light in the wavelength band of 510 to 560 nm
chosen since the human eye has its highest
response to wavelengths in the 550 nm range
relative response of a typical human eye
compared to various wavelengths of visible light
using two different lighting conditions are shown
the graph to the right.

Curve A at 100 lumens (100-foot-candles) is typical of a welllighted inspection bench


Curve B at 2 lumens (2-footcandles) is the maximum white
light level allowed in a fluorescent penetrant inspection booth
Under darkened condition, the sensitivity of the eye increases
about 30 times and shifts slightly to blue region
At light level of 2 lumens, it is possible for the eye to see
some light wavelengths below 400 nm and above 700 nm

8. Magnetic particle testing equipment


Black light equipment
Sources of UV (black) light
-

Incandescent lamps.
Metallic or carbon arcs.
Integrally filtered tubular fluorescent lamps.
Tubular fluorescent lamps
Enclosed mercury vapor arc lamps
Metal halide or halogen lamps..

Mercury vapor lamp


-

high-pressure component is a quartz tube containing some mercury plus a small


amount of neon gas
when lamp is first turned on, mercury condensed as a liquid and an arc between
electrodes cannot be generated, this is the reason for neon gas
a small amount of current, limited by the resistor, causes a discharge from starting
electrode through neon gas
this glow is sufficient to vaporize the mercury, which then allows arc to pass between
main electrodes
this starting procedure requires from 5 to 15-minutes to fully vaporize the mercury and
produce full output of black light

8. Magnetic particle testing equipment


Black light equipment
Mercury vapor lamp - requirements in testing
-

high pressure, mercury vapor, black light bulb requires a housing, filter, regulating ballast or
transformer, and connecting cables or wires
housing, which may be metal or plastic, serves several functions:
- hold and protect the bulb.
- hold and support the filter.
- prevent leakage of unwanted visible light.
- permit directing the beam on the surface to be inspected.
- provide a means for handling the bulb
filter is a special material that prevents passage of short wavelength ultraviolet (UV-B&-C) and
long wavelength visible light; transmits ultraviolet (peak at 340-380nm: Kopp 41 filter glass)
clean filter regularly and do not use cracked or ill-fitting filter
black light intensity varies almost linearly with line voltage and black light ballast or
transformer does not regulate line variations
below 90-volts, lamps will not sustain the mercury arc and lamp will extinguish, and not restart
until it has cooled
black light lamps should be connected to stable power sources; not available and line voltage
fluctuates, use a constant potential transformer
aging, dust and dirt build up, can result in as much as a 50-percent decrease in ultraviolet
radiation output
usage; a single start can equate to 2 or 3-hours of continuous use on operating life

8. Magnetic particle testing equipment


Black light equipment
Black Light Safety
-

ultraviolet radiation below 320 nm can be hazardous and may cause permanent effects.
the output of a black light bulb is principally at 365 nm and the amount of radiation at shorter
wavelengths rapidly falls off.
the amount of radiation emitted at or below 320 nm is typically less than 1-percent; however,
this quantity is enough to require a filter
germicidal, sun tanning, and mineral light bulbs that emit short and medium wavelength
ultraviolet light SHALL NOT be used for penetrant inspection
ultraviolet light filtering safety eyewear and gloves shall be used to minimize potential
detrimental health effects.
eyeball fluorescence under ultraviolet radiation
- the fluid in the eye will fluoresce when exposed to ultraviolet radiation
- an operator may experience this phenomenon as a clouding of the vision when the
ultraviolet radiation is reflected into the operators eyeball or if ultraviolet radiation is
reflected from highly reflective surfaces
- can usually be corrected by positioning the lamp so the radiation is not directed or reflected
into the inspectors eye
- use of eyewear designed to protect the eyes from UV-A and UV-B will reduce this effect
- inspector entering a darkened area SHALL allow at least 5-minutes for dark adaptation
before examining part.

8. Magnetic particle testing equipment


Black light equipment

Black Light dark adaptation


-

ability of the human eye to


see in various stages of
illumination
perception of contrast and
color are at a maximum in
bright light but are rapidly
lost in the dark
ability to discern faint light
sources is at a minimum in
bright light (florescence) but
at a maximum in the dark
this effect is of utmost
importance in black light
testing
behavior of human eye vs illumination level

8. Magnetic particle testing equipment


Black light equipment
Light sensitive (measuring) instruments
- measure white light; use a white light meter (photometer)
- measure UV (black) light; use a UV (black light) meter (radiometer)
- use a dual sensor photometer/radiometer

white-light meter
black-light meter

black & white-light meter

* minimum UV-A output for a black light SHALL be 1000 W/cm 2 measured at a
distance of 15 from the outside face of the filter.

9. Type of discontinuities detected by NDT


Types of discontinuities
Inherent discontinuities/flaws
- usually formed when the metal is molten
- inherent wrought flaws are related to melting and solidification of original ingot
before forming into slabs, blooms an billets
- inherent casting flaws relates to melting, casting and solidification of a cast article;
caused by variable such as inadequate feeding, gating, excessive pouring
temperature or entrapped gases
Processing discontinuities/flaws
- related to various processes like machining, forming, extruding, rolling, welding,
heat treating and plating
Services discontinuities/flaws
- relates to various in-service conditions like stress, corrosion, erosion and fatigue

9. Type of discontinuities detected by NDT


General flaws types
Product form:- Bursts (Forgings)
- Cold Shuts (Castings)
- Cracks (All Product Forms)
- Hot Tear (Castings)
- Inclusions (All Product Forms)
- Lamination (Plate, Pipe)
- Laps (Forgings)
- Porosity (Castings)
- Seams(Bar, Pipe)

9. Type of discontinuities detected by NDT


General flaws types
Welding:- Burn Through
- Cracks
- Excessive/Inadequate Reinforcement
- Inclusions (Slag/Tungsten)
- Incomplete Fusion
- Incomplete penetration
- Misalignment
- Overlap
- Porosity
- Root Concavity
- Undercut

9. Type of discontinuities detected by NDT


General flaws types
Service induced discontinuities:- Wear (Localized)
- Corrosion-Assisted Fatigue Cracks
- Corrosion - general, pitting
- Creep (Primary)
- Erosion
- Fatigue Cracks
- Hot Cracking
- Hydrogen-Induced Cracking
- lntergranular Stress-Corrosion Cracks
- Stress-Corrosion Cracks (Transgranular)

10. Interpretation and evaluation of indications


Relevant, Non-relevant and False Indications
Relevant Indications
- are produced by leakage fields which are the result of discontinuities.
- require evaluation with regard to acceptance standard/criteria
Non-relevant indications
- can occur singly or in patterns as a result of leakage fields created by conditions
that require no evaluation such as changes in section (like keyways and drilled
holes), inherent material properties (like the edge of a bimetallic weld), magnetic
writing etc.
False Indications
- are not the result of magnetic forces
- examples are particles held mechanically or by gravity in shallow depressions or
particles held by rust or scale on the surface.

10. Interpretation and evaluation of indications


Common discontinuities
Casting

Forging & Rolling

Welding

Misc

Pores
Blowholes
Piping
Inclusions
Shrinkage
Hot tears
Cracks
Cold shuts
Unfused chaplets
Misplaced core
Segregation

Laps
Cracks
Rolled-in scales
Scabs
Seams
Stringers
Laminations
Chevron
Bursts

Porosity
Pipe or wormholes
Non-metallic inclusion
Tungsten inclusion
Lack of fusion
Incomplete root
penetration
Cracks
Undercut
Concavity
overlap
Excessive penetration /
reinforcement
Lamellar tearing
Burn through
Laps

Cracks
Fatigue cracks
Stress crack
Heat cracks
Stress corrosion cracks
Corrosion
Grinding cracks
Heat treat cracks

10. Interpretation and evaluation of indications


Indications - pictures
Cracks

10. Interpretation and evaluation of indications


Indications - pictures
Seams, stringers, laps

10. Interpretation and evaluation of indications


Indications - pictures
Flakes/scabs

10. Interpretation and evaluation of indications


Indications - pictures
Forging burst

10. Interpretation and evaluation of indications


Indications - pictures
Lamination

10. Interpretation and evaluation of indications


Indications - pictures
Cold shuts

10. Interpretation and evaluation of indications


Indications - pictures
Porosity

10. Interpretation and evaluation of indications


Indications - pictures
Shrinkage

10. Interpretation and evaluation of indications


Indications - pictures
Blowholes (pipes)

10. Interpretation and evaluation of indications


Indications - pictures
Inclusions

10. Interpretation and evaluation of indications


Indications - pictures
Hot tears

10. Interpretation and evaluation of indications


Indications - pictures
Corrosion

10. Interpretation and evaluation of indications


Indications - pictures
Wear/erosion

10. Interpretation and evaluation of indications


Indications - pictures
Wear/erosion

10. Interpretation and evaluation of indications


Indications - pictures
Service induced cracks

10. Interpretation and evaluation of indications


Indications - pictures
Weld spatter, slag, undercut, misalignment, arc strike

10. Interpretation and evaluation of indications


Indications - pictures
Weld misc. discontinuities

10. Interpretation and evaluation of indications


Indications - pictures
Boiler (and tube) discontinuities

10. Interpretation and evaluation of indications


Indications - pictures
Boiler and heat exchanger tube thinning

10. Interpretation and evaluation of indications


Evaluation techniques
Interpretation:- determination of a magnetic particle indication's source and relevancy (distinguish
between relevant and non-relevant indications)
Evaluation:- process of determining the magnitude and significance of a discontinuity causing
an indication after it has been interpreted as being relevant.
Standards and references
- In order to proper carry out an inspection and evaluate any indications found we
need some guidance; hence the need for standards, specifications, acceptance
standards.
Comparison techniques
- In addition to standards; comparative pictures maybe used for evaluation (eg.
ASTM E125 : Standard Reference Photographs for Magnetic Particle Indications
on Ferrous Castings)
- In some instances actual reference standards (known defective part) may be used
at the start of a run to check the system

10. Interpretation and evaluation of indications


Evaluation techniques
Specifications
- Specifications usually details what is to be performed (eg. scope, calibrations,
types of shots, coverage, test parameters, personnel certification etc.)
- Most end user will have specification outline their NDE requirements and will
usually reference standards and codes (eg Dow Chemicals specifications for
pressure vessels references ASME codes; AugustaWestland references BS/EN
standards)
Certifications
- company certification may be required to ensure that the facility or shop is capable
of performing the required inspection to the end user requirements (eg ASME
certification or CWB 178)
- personnel certification is required to attest to the technicians qualification
(capability) to performed the inspection and evaluate the indications found which
maybe in-house (SNT-TC-1A), end user specific (AugustaWestland), or nationally
accredited (eg. CGSB)

10. Interpretation and evaluation of indications


Defect Appraisal

History of part
- Weld on pressure vessel
Manufacturing process
- SMAW, ground smooth
Possible causes of defect
- cracks (too high heat)
Use of part
- Waste water/chemicals
Acceptance and rejection criteria
- ASME VIII Div 1 Appendix 6
Use of tolerances
- No linear indication > 1/16

10. Interpretation and evaluation of indications


Defect Appraisal

History of part
- Casting (new)
Manufacturing process
- Sand cast, sand blasted surface
Possible causes of defect
- cracks (due uneven cooling)
Use of part
- Fitting for a hub
Acceptance and rejection criteria
- MSS SP-53
Use of tolerances
- max acceptable 0.3 ( 8 mm) long for
materials up to 0.5 (13 mm) thick

11. Standards, specifications, codes and


reports
Standard CAN/CGSB 48.9712

Non-destructive testing- Qualification and certification of NDT personnel


2014 edition; published by CSA
Scope:This International Standard specifies requirements for principles for the
qualification and certification of personnel who perform industrial nondestructive testing (NDT)

Methods:
a) acoustic emission testing;
b) eddy current testing;
c) infrared thermographic testing;
d) leak testing (hydraulic pressure tests excluded);
e) magnetic testing;
f) penetrant testing;
g) radiographic testing;
h) strain gauge testing;
i) ultrasonic testing;
j) visual testing (direct unaided visual tests and visual tests carried out during the
application of another NDT method are excluded)
* Go thru some of the standard relating to MT certification

11. Standards, specifications, codes and


reports
Standards, specifications and codes

Codes
-

generally the top-tier documents, providing a set of rules that specify the minimum acceptable
level of safety for manufactured, fabricated or constructed objects
may incorporate regulatory requirements and will often refer out to standards or specifications
for specific details on additional requirements not specified in the Code itself
examples: ASME Boiler and Pressure Vessel Code (B&PVC) and AWS D1.1 Structural
Welding Code Steel

Standards
-

documents that establish engineering or technical requirements for products, practices,


methods or operations
example those that provide requirements for performing NDT (eg ASTM E709 : Standard
Guide for Magnetic Particle Testing, and ASTM E 1444, Standard Practice for Magnetic
Particle Testing)

Specifications
-

provide specific requirements for materials, components or services


often generated by private companies (owners/end-users) to address additional requirements
applicable to a specific product or application
often listed in procurement agreements or contract documents as additional requirements
above and beyond code or standard requirements

11. Standards, specifications, codes and


reports
Standards, specifications and codes

NDT Procedures
-

written by companies to describe how an NDT method is carried out in the facility and/or a
specific project or contract
reference codes, standards and/or specifications that may be required for the NDT work to be
performed

Written/work instructions
-

step by step instructions on how a specific NDT task is to be performed

Technique sheets
-

detailed steps and/or sequences of operations for a specific NDT task


will include specific inspection parameters for the NDT task

Reports
-

written testimony of the NDT work performed and the outcome (eg. accept/reject)
include inspection parameters including acceptance criteria
may include sketches or pictures showing area tested or for disposition (eg repair/scrap)
include technicians name and certification

11. Standards, specifications, codes and


reports
Standards, specifications and codes

Defining the scope of the examination


- The scope of the examination has to be defined from the start ie. what is to be
performed (eg RT or UT), the area(s) or part/component to be inspected, what
standard/specification/code to use, acceptance standard/criteria to evaluate the
indications to, personnel certification etc.
Acceptance criteria (NDT)
- Specified indicators or measures used to assessing any indications found during
the inspection (eg. no cracks; no linear indication > 1/16)
Establishing specifications
- Owner/end-user (engineer) will put forward a specification that will be deployed in
conjunction with the contractual NDT work to be performed
Technical evaluation of given specifications
- Prior to the start of a job or contract, the specification will be reviewed to ensure all
the requirements are met (eg. equipment, certification etc.)
- Usually carried out by an NDT technically competent person

11. Standards, specifications, codes and


reports
Reports

Establishing reports
- A written testimony of the inspection is usually required in any inspection to
document the inspection work performed
Technical requirements of reports
- A report will include the parameter used in the inspection (eg. project, part #,
code/specification used, procedure used, equipment, environment, inspection
settings, personnel name and certification etc.)
Technical evaluation of reports
- The results will usually reference a code/specification (acceptance criteria); and
maybe a sketch/picture of area(s) tested or for disposition.
-

Corrective actions
An acceptable part is usually put into use or work to proceed; while and
unacceptable one will be disposition by the owner/end-user (eg. re-work, repair,
scrap, use as is etc.)

11. Standards, specifications, codes and


reports
Reports

What was
inspected
What were the
inspection
parameters
What was
found

Who
performed
inspection

What was
result and
disposition

11. Standards, specifications, codes and


reports
Review of Specification/Standard/Code

Review one or more of the following:- ASME V Article 7


- ASME VIII Div 1 Appendix 6
- CSA W59 (MT only)
- ASTM E709
- ASTM E125
Samples on how to do evaluation

12. Quality control of equipment and processes


Proper functioning of equipment and accessories
-

In order to get the right results; all the equipment and accessories used must be
functioning properly
Either it has to be calibrated or attested that it complies with the specification,
standard and/or code that is specified for the NDT work
Calibration frequency is usually specified in the codes, standards or specifications

ASTM E709

12. Quality control of equipment and processes


Proper functioning of equipment and accessories
- Aircraft related checks

Helicopter
specification

12. Quality control of equipment and processes


Proper magnetic particles and bath suspension
Checking the particle concentration in a bath (wet
florescent)
use a 100 ml pear shaped centrifuge tube, or
equivalent, graduated to 1 ml in 0.05 ml increments,
- agitate the suspension a minimum of 30 minutes.
- fill the pear-shaped centrifuge tube to the 100 ml
mark,
- demagnetise and allow the suspension to settle for at
least 60 minutes,
- read the volume of settled particles and examine with
a black light, for contamination

Particle concentration shall be:- 01 to 0.4ml/100ml

12. Quality control of equipment and processes


Process control
Technique sheets
- detailed steps and/or sequences of
operations for a specific NDT task
- ensure everyone does the work the
same way
- ensure quality of the work
performed as technique sheets
have to approve prior to use
- consistent outcome or results

12. Quality control of equipment and processes


Process control
Control of wet method particle concentration
- Brilliance and contamination
- in-use ink (bath) shall be checked under UV-A against the reference sample stored ; any of
the following conditions are unacceptable and shall require replacement of the in-use ink
- a noticeable reduction in the fluorescent brightness of the in-use ink relative to the reference
sample,
- clouding of the in-use ink (bath) carrier fluid to the extent that the markings on the flask
between 5ml and 25ml cannot be seen through the carrier fluid,
- milky white or bluish white fluorescence of the carrier fluid (due to oil or grease
contamination).
-

Verifying illumination - visible (white) / UV (backlight)


- black light filters shall be verified for cleanliness and integrity; contaminated filters shall be
cleaned and damaged filters shall be replaced.
- black light intensity shall be checked using a calibrated radiometer (UV meter) at a distance of
15" (38cm) from the filter of the lamp; the minimum acceptable radiance shall be 1,000
W/cm2
- the inspection area (florescent inspection) shall be verified for background white light; the
maximum intensity shall be 2 foot-candles (20 lx),
- the white light intensity of the visible inspection, used to verify fluorescent indications shall be
checked, the minimum intensity shall be 100 foot-candles (1,000 lx).

12. Quality control of equipment and processes


Process control
Calibration of current output using shunts
- accuracy of the equipment ammeter shall be verified with a calibrated ammeter shunt connected
to the head and tail stock contacts
- comparative readings shall be taken at least at three levels of output current encompassing the
usable range of the equipment
- The equipment meter reading shall not deviate from the current level indicated by the shunt by
more than 50 A or 10% of the actual ammeter output of the magnetising equipment,
whichever is the greater

Verifying the magnetic field


- a tangential field strength meter based on the Hall effect and capable of measuring the specified
values,
- a set of magnetic flux indicators (flexible laminated strips) compliant with ASTM E 1444, - a set
of reference notched shims compliant with SAE AS5371,

12. Quality control of equipment and processes


Process control
Quick break test
- use a quick-break tester or a suitable oscilloscopes

13. Instruction writing


Written Instructions
Ability to prepare a detailed NDT instruction providing written step by step information
on the testing of a sample and to provide the instruction by application
- Step-by-step review of how to write a sample written instruction
- Shall include:
a. A description of the test specimen.
b. A list of equipment, reference standards and accessories used.
c. A description of the calibration procedures specific for the test
specimen.
d. A description of the inspection procedures specific for the test
specimen.
e. The instrument settings at the time of inspection.
f. A report of the results.

Vous aimerez peut-être aussi