Académique Documents
Professionnel Documents
Culture Documents
NGDiffServ?
SDH?
What
SURPASS
Next Generation
Management
NGN Control
SURPASS
Next Generation
Switching
NGN Control
Media
Gateways
Application/Video Servers
PSTN/
Mobile Network
NGN Core
SURPASS
Next Generation
Optics
IP/Optical
Backbone
NGN Access
Media
Gateway
Triple Play
Voice, Video, Data
Residential Customers
Access
Gateway
Metro
Optics
Multi-Service
Access
CPE
PBX
LAN
SURPASS
Next Generation
Access
Business Customers
Fig. 2 Next Generation Architecture (TR3271EU00TR_0402 Hardware and functionality, 5)
Data/Internet
Leased Lines
Key objectives:
Growth & traffic mix
Layered
Transport
Network
Switch
Operational Efficiency
Regional/
Metro Core
Metro
Access/Edge
Mobile
Other carrier
Multi-Service
Optical Networks
Transparent
Optical Networks
Telecommunication
Network
Management
System
TNMS
Backbone/
Regional
SURPASS hiT
7500
SDH
SN16000
Regional/
Metro Core
Metro
WDM
SURPASS hiT
FSP
Multi Service
Optical
Networks
SX/SL/
SMA
SURPASS hiT
7070/7060
ISP
ISP
POP
POP
Metro
Access/Edge
CPE
Next-Gen.
SDH
SDH
Next-Gen.
SDH
SURPASS hiT
SDH
7060/7050
SMA
GbE
GbE
GbE
GbE
Business
Customer
CPE
Enterprise
(Storage Area Networks)
SAN
SURPASS hiT
7030/7020
CPE
Service
transparency
Next Gen.
SDH
Carrier-grade
Ethernet
TNMS
Configuration
Tool
Multi-Service
Provisioning
Platform
TNMS
TNMS
Fig. 7 SURPASS Multi Service Optical Networks (TR3271EU00TR_0402 Hardware and functionality, 11)
Fig. 8 SURPASS Multi Service Optical Networking (TR3271EU00TR_0402 Hardware and functionality, 11)
Decreasing Footprint
Improving Scalability and Flexibility (Any Size/Any Service Mix)
Increasing Port Density
Integrated VC4/VC12 Switching Fabrics
Use of new technologies like GFP, VC and LCAS which allow for:
Efficient support of data applications (Ethernet, SAN)
Offering granularity of bandwidth
Improved network utilization and efficiency
Fast/flexible bandwidth and service provisioning capabilities
Fig. 9 What is Next Generation SDH? (TR3271EU00TR_0402 Hardware and functionality, 13)
Optical,
Metro Core
& Access
SN 16000
FSP series
Metro WDM
TNMS
Network Management Solution
Fig. 10 SURPASS hiT portfolio overview (TR3271EU00TR_0402 Hardware and functionality, 15)
Fig. 11 SURPASS hiT 70 series: Feature Summary (TR3271EU00TR_0402 Hardware and functionality, 15)
Fig. 12 SURPASS hiT 70 series: Feature Summary (TR3271EU00TR_0402 Hardware and functionality, 17)
FSP 1500
Fig. 13 SURPASS hiT 70 series: Feature Summary (TR3271EU00TR_0402 Hardware and functionality, 17)
TMX
TMX
TDM/Data
Traffic
Working Line
Protection Line
TDM/Data
Traffic
TMX
ADMX
Working
Line
TMX
Working
Line
Protection
Line
TDM/Data
Traffic
Protection
Line
TDM/Data
Traffic
Fig. 14 TMX and ADMX Application (TR3271EU00TR_0402 Hardware and functionality, 19)
LXC Application
TDM/Data
Traffic
ADMX/TMX
ADMX/TMX
TDM/Data
Traffic
ng
r ki
o
W ine
L
Wo
rki
Lin ng
e
TDM/Data
Traffic
ADMX/TMX
Pro
t ec
t
Lin ion
e
g
rkin
Wo ne
Li
n
ctio
e
t
Pro ine
L
LXC
LXC
n
tio
c
e
t
Pro Line
Wo
rkin
Lin g
e
ADMX/TMX
TDM/Data
Traffic
Pr o
te c
Lin tion
e
TMX/ADMX
TMX/ADMX
TDM/Data
Traffic
32 x
TDM/Data
Traffic
TMX/ADMX
TMX/ADMX
TDM/Data
Traffic
40 Gbps ( 1, 2, 3, 4)
Fig. 16 Metro WDM and 40G WDM Application (TR3271EU00TR_0402 Hardware and functionality, 21)
SL16
hiT 7070
SMA16
hiT 7070
hiT 7070
SMA16
SL16
SL16
SMA16
2,5 Gbps
hiT 7070
SMA16
2,5 Gbps
A
A
hiT 7070
2,5 Gbps
SL16
SL16
SMA4/1
C
STM-N
hiT 7070
SMA16
SMA16
SMA4/1
D
hiT 7050
D
hiT 7050
Fig. 17 Multiple rings and ring gateways (TR3271EU00TR_0402 Hardware and functionality, 23)
Official documentation
T
E
D
I
T
M
N
O
G
L
G
U
I
M
N
Documentation on CD-ROM
Fuse Panel
Cables
Terminal Panel
2200 mm
Height-adjustable feet
600 mm
300 mm
Fig. 23 Siemens rack for SURPASS hiT 70xx (TR3271EU00TR_0402 Hardware and functionality, 35)
Air Filter
Traffic Slot
Traffic Slot
CLU Slot
Traffic Slot
Traffic Slot
SCOH Slot
Traffic Slot
Traffic Slot
Traffic Slot
Cable Duct
Traffic Slot
Cable Duct
Core Slot/VC-4 Switch
Traffic Slot
Traffic Slot
FAN UNIT
Traffic Slot
Traffic Slot
Traffic Slot
Traffic Slot
Traffic Slot
CLU Slot
CLU Slot
LSU Slot
LSU Slot
PDH Slot
LSU Slot
LSU Slot
PDH Slot
LSU Slot
LSU Slot
PDH Slot
LSU Slot
Traffic Slot
SCOH Slot
Traffic Slot
Traffic Slot
Traffic Slot
Traffic Slot
Traffic Slot
Traffic Slot
Traffic Slot
Traffic Slot
LSU Slot
PDH Slot
825 mm
Traffic Slot / E-Core Slot
FAN UNIT
Cable Duct
FAN UNIT
Air Filter
Fig. 24 SURPASS hiT 7070 Core Shelves (TR3271EU00TR_0402 Hardware and functionality, 37)
Cable
Duct
MS-COPA
LSU
#4
LSU
LSU
IF2M (W)
#3
LSU
LSU
IF2M (W)
LSU
#2
IF2M (W)
LSU
LSU
#1
IF2M (W)
IF2M (P)
ESM-CORE Y
400 mm
ESM-CORE X
MS-AP
MS-ILANS
Fig. 25 SURPASS hiT7070 PDH MicroShelf (TR3271EU00TR_0402 Hardware and functionality, 39)
Fig. 26 SURPASS hiT 7070: Protectionshelf (TR3271EU00TR_0402 Hardware and functionality, 39)
Fan Unit
201
202
Main Board
Traffic slot
203
Fig. 27 SURPASS hiT 7050 FP1 (TR3271EU00TR_0402 Hardware and functionality, 41)
UBAT
1
EQUIPMENT-AL COM-AL
4 MAJOR MINOR MAJOR MINOR ACO ACO-B
QF2
RJ45 connector
RJ11 connector
Ground Jack
Push-button
Fig. 28 Network Element Alarm Panel NEAP (TR3271EU00TR_0402 Hardware and functionality, 43)
UBAT
1
Fig. 29 PDH MicroShelf Alarm Panel MS-AP (TR3271EU00TR_0402 Hardware and functionality, 43)
BATT4
BATT3
CES
QEXT
Q
EOW
CANEX
TIF
AUX 4
AUX 3
AUX 2
AUX 1
T3/T4
T3/T4
BATT2
BATT1
Up
MS1
MS-ILANS
UBAT1
MS2
MS3
UBAT2
Fig. 31 PDH MicroShelf Connector Panel MS-COPA (TR3271EU00TR_0402 Hardware and functionality, 45)
Protectionshelf PS-COPA/NEAP
T3 2 MHz
T3 2 Mbit/s
T4 2 MHz
T4 2 Mbit/s
Fig. 33 Clock Adapter Box T3/T4 (TR3271EU00TR_0402 Hardware and functionality, 49)
SCOH
COPA
Power Supply
Adapter
Power Supply
CAN
IF
external CAN
ext.
CAN
IF
Relay 1
CAN
IF
Relay 2
FPGA
Relay 3
Relay 4
hiT 7070
SC / DC
DB-9 connector
MAJOR
MINOR
AND-BATT
QLink
DB-25 connector
TIF/Alarms
T3/T4
2 1
UBAT
EOW
Major
Minor
ACO
OK Fault
Power 48/60 V
Fig. 35 Alarm indications and service connectors hiT 7050 FP1 (Rel.1) (TR3271EU00TR_0402 Hardware and functionality, 51)
TIF/Alarms
T3/T4
2 1
UBAT
EOW
Major
Minor
ACO
SDI
OK Fault
Power 48/60 V
Fig. 36 Alarm indications and service connectors hiT 7050 FP1 (Rel.2) (TR3271EU00TR_0402 Hardware and functionality, 51)
Air filter
FAN UNIT
Air Filter
Traffic Slot
Traffic Slot
Traffic Slot
Traffic Slot
CLU Slot
CLU Slot
Traffic Slot
Traffic Slot
Traffic Slot
Traffic Slot
Traffic Slot
Traffic Slot
Traffic Slot
Traffic Slot
FAN UNIT
Cable Duct
Fan units
Fig. 37 Fan units SURPASS hiT 7070 (TR3271EU00TR_0402 Hardware and functionality, 53)
Cable Duct
General Purpose (I) Slot
Traffic Slot
Traffic Slot
Traffic Slot
Traffic Slot
Air Filter
Air filter
201
Slot 101
Slot 102
Slot 103
Fan
Slot 202
Main Board
Slot 203
Fan unit
Fig. 38 Fan units SURPASS hiT 7050 FP1 (TR3271EU00TR_0402 Hardware and functionality, 53)
Fig. 39 Half height card, mechanical design (TR3271EU00TR_0402 Hardware and functionality, 54)
Fig. 40 Standard card, mechanical design (TR3271EU00TR_0402 Hardware and functionality, 55)
Fig. 41 Insertion and extraction aid (TR3271EU00TR_0402 Hardware and functionality, 55)
Fig. 42 SURPASS hiT 7050 FP1 MFP1 drawer (TR3271EU00TR_0402 Hardware and functionality, 56)
Fig. 43 SURPASS hiT 7050 FP1 P1-42 drawer (TR3271EU00TR_0402 Hardware and functionality, 56)
Fig. 44 SURPASS hiT 7050 FP1 P3-3 drawer (TR3271EU00TR_0402 Hardware and functionality, 57)
Fig. 45 SURPASS hiT 7050 FP1 E100-8 drawer (TR3271EU00TR_0402 Hardware and functionality, 57)
Fig. 46 SURPASS hiT 7050 FP1 O155-4 and O1000-4 drawers (TR3271EU00TR_0402 Hardware and functionality, 57)
T3
160G
Central
Clock
Unit
Q / Q-F2 / Qext
4 x X.21
Central
Controller
SDH
Card
...
Ethernet
Card
...
SDH
Card
Extension
Link Card
...
To/from
PDH
MicroShelf
Packet
Fabric
.....
Low
LowOrder
Order
Switch
Switch
...
PDH
Card
EOW (E&M)
...
TIF
PDH
Card
VC-4 Switch
...
PDH
Card
...
T4
PDH
Card
General
Purpose
Card
VC-3/12
VC-3/12
Fig. 47 SURPASS hiT 7070: Block Diagram (TR3271EU00TR_0402 Hardware and functionality, 59)
PDH
PDH Card
PDH Card
Traffic Slots
PDH Card
Fig. 48 PDH MicroShelf: Block Diagram (TR3271EU00TR_0402 Hardware and functionality, 59)
CARD
FUNCTIONALITY
Core Cards
CTRL &
OH Access
SCOH
Switch Fabric
SF160G
160G@VC-4
Optical Amplifier
and Booster Cards
(Card Protection)
WDM Cards
Switch Fabric
2.5G/10G SF2G5/
@VC-12 SF10G
W
(Card Protection)
Ethernet Cards
Packet Fabric
PF2G5
2.5G
SETS
(Card Protection)
CLU
W
P
W
P
PDH Cards
W
P
SDH Cards
Fig. 49 Card Functionality: Core Cards (TR3271EU00TR_0402 Hardware and functionality, 61)
Fig. 50 STM-1/-4/-16 and opt. Ethernet Cards with SFP Modules (TR3271EU00TR_0402 Hardware and functionality, 63)
CARD
FUNCTIONALITY
Core Cards
IFO155M-E
P
8 x STM-1
electrical
(1+1, 1:1, 1:N MSP Protection
1:N Card Protection)
IFO155M
S
F
P
P W
8 x STM-1
optical
WDM Cards
IFQ622M
S
F
P
P W
4 x STM-4
(1+1, 1:1, 1:N MSP Protection)
SDH Cards
1x STM-16
IFS2G5
P
IFS2G5B
P
S
F
P
IFQ2G5
P
S
F
P
Ethernet Cards
1x STM-16
(1+1, 1:1, 1:N MSP or
BSHR/2 or BSHR/4)
4 x STM-16
(1+1, 1:1, 1:N MSP or
BSHR/2 or BSHR/4)
STM-64
IFS10G(B)/
IFS10G-WDM (1+1, 1:1, 1:N MSP or
P
BSHR/2 or BSHR/4)
IFS10G-M/
STM-64 colored
IFS10G-R/
(1+1, 1:1, 1:N MSP or
IFS10G-WLS
W
BSHR/2 or BSHR/4)
PDH
Cards
Fig. 51 Card Functionality: SDH Cards (TR3271EU00TR_0402 Hardware and functionality, 65)
CARD
FUNCTIONALITY
WDM Cards
DoubleCore Only
IFS40G-MX
4 x 10G
Core Cards
Optical Amplifier
and Booster Cards
IFSOA
IFSOA-PDC
IFSOB
IFSOB-PDC
1 x V-64.3 or
JE47dB-16.2/3
1 x V-64.2a
1 x L-64.3 or
S-64.2b SFO
1 x L-64.2b
Ethernet Cards
SDH Cards
PDH Cards
Fig. 52 Card Functionality: WDM, Optical Amplifier and Booster Cards (TR3271EU00TR_0402 Hardware and functionality, 67)
CARD
FUNCTIONALITY
WDM Cards
Core Cards
Optical Amplifier
and Booster Cards
Ethernet Cards
IFQGBE(B)
GFP-F
IFQGBE(B)-E
IFOFE
4 x GbE
optical
S
F
P
4 x GbE
electrical
S
F
P
8 x FE
optical
IFOFE-E
8 x FE
electrical
IFOFES-E
8 x FE
electrical
PDH Cards
SDH Cards
Fig. 53 Card Functionality: Ethernet Cards (TR3271EU00TR_0402 Hardware and functionality, 69)
CARD
FUNCTIONALITY
SDH Cards
WDM Cards
Core Cards
Optical Amplifier
and Booster Cards
Ethernet Cards
PDH Cards
SC and Microshelf only
IF345M
P
3 x 34/45M
(1+1 Card
Protection)
LSU
32 x 2M
(2 Cards
per IF2M)
IF2M
P W
63 x 2M
(1:N Card
Protection)
Fig. 54 Card Functionality: PDH Cards (TR3271EU00TR_0402 Hardware and functionality, 71)
A~3dB
IN
OUT
STM-N
optical
AIS
A~3dB
J0
=
Reflection
ALS
J0
Fig. 55 Single fiber mode for STM-1/-4/-16 interfaces (TR3271EU00TR_0402 Hardware and functionality, 73)
= 1530 - 1543nm
Tx
Tx
Rx,Tx
Rx,TX
Rx
= 1548 - 1561nm
STM-64 interface
Filter
Filter
Rx
= 1530 - 1543nm
STM-64 interface
Fig. 56 Single fiber mode for STM-64 S-64.2b/3b interfaces (TR3271EU00TR_0402 Hardware and functionality, 73)
TIF Alarm
OHX/DCC/SSM
TDM Switch
VC-4/3/12
MSC
STM-4
SETS
O622-2/
O622C-2
O622-2
O622C-2
STM-4
PSC
PFP1/
EOW
E155-4
O155-2
O155-4
STM-1
P1-21/
P1-42
P3-3
...
...
2 Mbit/s
34/45
Mbit/s
E100-4/
E100-8
E100S-8
O1000-4
...
10/100BaseTX GbE SX/LX
Fig. 57 SURPASS hiT 7050 FP1: Block Diagram (TR3271EU00TR_0402 Hardware and functionality, 75)
Card Functionality
SDH Cards
CTRL &
Switch Fabric &
MFP1
SETS &
EOW &
Auxiliary &
PSU
O622-2/
O622C-2
S
F
P
2 x STM-4
optical
(1+1 MSP Protection)
O155-2/
O155-4
S
F
P
2 x STM-1
optical
Ethernet Cards
O1000-4
S
F
P
4 x GbE
Fan unit
FFP1
4 x STM-1
electrical
E155-4
E100S-8
8 x FE
E100-8
8 x FE
E100-4
4 x FE
Core Cards
PDH Cards
P3-3
3 x 34/45Mbit/s
P1-21/
P1-42
21/42 x 2Mbit/s
Fig. 58 SURPASS hiT 7050 FP1: Card Functionality (TR3271EU00TR_0402 Hardware and functionality, 77)
Air Filter
COPA
Cable Duct
Cable Duct
CLU Slo t
Traffic Slo t
Traffi c Slot
Traffic Slo t
Traffi c Slot
SCOH Slo t
Traffic Slo t
Traffic Slo t
CLU Slo t
Cable Compartment
Traffi c Slot
Traffi c Slot
COPA
Air Filter
COPA
Core Slot
Air Filter
FAN UNIT
FAN UNIT
SCOH Slo t
Traffic Slot
Traffic Slot
Traffic Slot
Traffic Slot
Traffic Slot
Core Slot
Core Slot
LSU Slot
CLU Slo t
CLU Slo t
LSU Slot
LSU Slo t
PDH Slo t
LSU Slot
LSU Slo t
PDH Slo t
LSU Slot
LSU Slo t
PDH Slo t
Core Slot
Cable Compartment
FAN UNIT
LSU Slo t
Traffic Slo t
Fuse Panel
Traffic Slo t
Fuse Panel
Traffic Slo t
FAN UNIT
Traffic Slot
PDH Slo t
Traffic Slot
Traffic Slot
CLU Slot
SCOH Slot
CLU Slot
LSU Slot
Traffic Slot
LSU Slot
Traffic Slo t
PDH Slot
LSU Slo t
LSU Slot
PDH Slo t
LSU Slot
LSU Slot
PDH Slot
Traffic Slot
Traffic Slo t
Traffic Slo t
Core Slot
Core Slo t
NEAP
Traffic Slot
LSU Slot
LSU Slot
PDH Slo t
Traffic Slot
Traffic Slot
Traffic Slot
Traffic Slo t
NEAP
Traffic Slot
Traffic Slot
Traffic Slot
CLU Slot
CLU Slot
LSU Slot
LSU Slot
PDH Slot
LSU Slo t
LSU Slot
PDH Slo t
LSU Slot
LSU Slot
PDH Slot
LSU Slot
LSU Slot
PDH Slo t
Traffic Slot
Traffic Slot
SCOH Slot
Traffic Slot
Traffic Slo t
Traffic Slot
Traffic Slo t
Traffic Slo t
Core Slot
Core Slo t
Traffic Slot
Traffic Slot
Traffic Slot
Traffic Slo t
Cable Duct
FAN UNIT
NEAP
FAN UNIT
NEAP
FAN UNIT
FAN UNIT
Cable Duct
Air Filter
COPA
Fig. 59 Rack with two SURPASS hiT 7070 SC or one SC and one DC sub-racks (TR3271EU00TR_0402 Hardware and functionality, 79)
Air Filter
COPA
Cable Duct
CLU Slot
Traffi c Slot
Traffic Slot
Traffic Slot
Traffi c Slot
Traffic Slot
Traffic Slot
SCOH Slot
Traffi c Slot
Traffi c Slot
Core Slot
Core Slot
Traffi c Slot
Cable Duct
Traffi c Slot
Traffi c Slot
Traffi c Slot
Traffi c Slot
CLU Slot
COPA
NEAP
FAN UNIT
Air Filter
FAN UNIT
Air Filter
COPA
FAN UNIT
Cable Duct
Cable Duct
Traffi c Slot
Traffi c Slot
Traffic Slot
Traffi c Slot
Traffic Slot
SCOH Slot
Traffic Slot
Traffi c Slot
Core Slot
Traffic Slot
Core Slot
Traffi c Slot
Traffi c Slot
Traffic Slot
CLU Slot
Traffic Slot
Cable Duct
CLU Slot
Cable Duct
Traffic Slot
Traffi c Slot
Traffi c Slot
Traffic Slot
SCOH Slot
Traffic Slot
Traffic Slot
Traffi c Slot
Traffi c Slot
Traffi c Slot
Traffi c Slot
Traffi c Slot
Traffi c Slot
CLU Slot
Traffic Slot
Traffic Slot
Traffi c Slot
Traffi c Slot
Core Slot
Core Slot
Traffi c Slot
Traffi c Slot
Traffi c Slot
Traffi c Slot
CLU Slot
Fuse Panel
Fuse Panel
FAN UNIT
NEAP
Cable Compartm ent
FAN UNIT
NEAP
Fig. 60 Rack equipping with SURPASS hiT 7070 DC Sub-racks (TR3271EU00TR_0402 Hardware and functionality, 81)
FAN UNIT
Traffi c Slot
Traffi c Slot
Traffi c Slot
Cable
Duct
MS-COPA
Cable
Duct
LSU
MS-COPA
LSU
CLU Slot
Traffic Slot
SCOH Slot
Traffic Slot
Traffic Slot
Traffic Slot
Traffic Slot
Traffic Slot
Traffic Slot
Core Slot
Traffic Slot
CLU Slot
FAN UNIT
FAN UNIT
COPA
FAN UNIT
Cable Duct
COPA
Air Filter
MS-AP
MS-AP
Fig. 61 Rack with one hiT 7070 Core Shelf and one PDH MicroShelf
(TR3271EU00TR_0402 Hardware and functionality, 83)
MS-ILANS
LSU
IF2M (W)
#4
LSU
LSU
IF2M (W)
#3
LSU
LSU
Core Slot
General Purpose Slot
Cable Compartment
IF2M (W)
#2
Traffic Slot
Traffic Slot
Traffic Slot
CLU Slot
Traffic Slot
Cable Duct
General Purpose Slot
Cable Duct
Traffic Slot
Traffic Slot
Traffic Slot
Traffic Slot
SRD-MSI
SCOH Slot
CLU Slot
LSU Slot
LSU Slot
PDH Slot
LSU Slot
LSU Slot
PDH Slot
LSU Slot
LSU Slot
PDH Slot
LSU Slot
LSU Slot
PDH Slot
LSU
IF2M (P)
Air Filter
IF2M (W)
#1
LSU
Traffic Slot
Traffic Slot
Traffic Slot
Traffic Slot
Traffic Slot
Core Slot
Core Slot
Traffic Slot
Traffic Slot
Traffic Slot
Traffic Slot
SRS-MSI
ESM-CORE Y
ESM-CORE X
Microshelf-MSI
MS-ILANS
LSU
IF2M (W)
#4
LSU
LSU
IF2M (W)
#3
LSU
LSU
IF2M (W)
#2
LSU
LSU
IF2M (W)
#1
IF2M (P)
ESM-CORE Y
ESM-CORE X
Microshelf-MSI
Rack with one hiT 7070 Core Shelf and one PDH MicroShelf
NEAP
Cable Compartment
NEAP
FAN UNIT
Cable
Duct
MS-COPA
LSU
LSU
IF2M (W)
#4
LSU
LSU
IF2M (W)
#3
LSU
LSU
IF2M (W)
#2
LSU
LSU
IF2M (W)
#1
IF2M (P)
ESM-CORE Y
ESM-CORE X
Microshelf-MSI
MS-AP
Fig. 62 Rack with two PDH MicroShelves (TR3271EU00TR_0402 Hardware and functionality, 83)
MS-ILANS
LSU
MS-AP
LSU
LSU
MS-ILANS
LSU
IF2M (W)
#4
MS-COPA
LSU
IF2M (W)
#3
LSU
LSU
IF2M (W)
#2
Cable
Duct
LSU
IF2M (W)
#1
IF2M (P)
ESM-CORE Y
ESM-CORE X
Microshelf-MSI
COPA
Air Filter
Cable Duct
Cable Duct
Air Filter
FAN
UNIT
COPA
CLU Slot
Traffic
Slot
Traffic
Slot
Traffic
Slot
Traffic
Slot
Core Slot
CLU Slot
FAN UNIT
SCOH Slot
Traffic
Slot
Traffic
Slot
Traffic
Slot
Traffic
Slot
Cable
Compartment
NEAP
NEAP
FAN
UNIT
Cable Duct
Fig. 63 Rack with one hiT 7070 Core Shelf and one Protectionshelf
(TR3271EU00TR_0402 Hardware and functionality, 85)
FAN UNIT
General Purpose Slot
Cable
Compartment
Core Slot
Microshelf-MSI
Protectionshelf
Traffic
Slot
Traffic
Slot
Traffic
Slot
Traffic
Slot
CLU Slot
CLU Slot
LSU Slot
LSU Slot
PDH Slot
LSU Slot
LSU Slot
PDH Slot
LSU Slot
LSU Slot
PDH Slot
LSU Slot
LSU Slot
PDH Slot
Microshelf-MSI
Traffic
Slot
Traffic
Slot
Traffic
Slot
Traffic
Slot
SRD-MSI
SCOH Slot
Traffic
Slot
Traffic
Slot
Traffic
Slot
Traffic
Slot
Traffic
Slot
Core Slot
Core Slot
Traffic
Slot
Traffic
Slot
Traffic
Slot
Traffic
Slot
SRS-MSI
Rack with one hiT 7070 Core Shelf and one Protectionshelf
Protectionshelf
Fig. 64 Six hiT 7050 FP1 in one rack (TR3271EU00TR_0402 Hardware and functionality, 87)
2
0
4
SF160G
SF160G
Traffic Slot
Traffic Slot
Traffic Slot
Traffic Slot
1
0
5
1
0
7
1
0
9
1
1
0
1
1
1
1
1
2
Cable Duct
2
0
5
2
0
6
2
0
7
2
0
8
FAN UNIT
FAN UNIT
Air Filter
1
1
3
2
0
9
2
1
0
2
1
1
2
1
2
2
1
3
Fig. 65 Sub-rack equipping of SURPASS hiT 7070 DC (TR3271EU00TR_0402 Hardware and functionality, 89)
Cable Duct
1
1
4
SCOH Slot
Traffic Slot
1
0
4
Traffic Slot
Traffic Slot
1
0
3
Traffic Slot
Traffic Slot
1
0
2
Traffic Slot
Traffic Slot
1
0
1
Traffic Slot
Traffic Slot
2
0
3
Traffic Slot
2
0
2
Traffic Slot
2
0
1
General Purpose card
Traffic Slot
1
1
3a
Rw P or P
Re W or W
Re P or P
SF160G W
SF160G P
Rw W or W
Rw P or P
Re W or W
Re P or P
BSHR/4 or 1:N
Group 1
Rw W or W
1
0
1
1
0
2
1
0
3
1
0
4
1
0
5
1
0
7
1
0
9
1
1
0
1
1
1
1
1
2
W
1
1
3b
BSHR/4 or 1:N
Group 2
Cable Duct
Rw W or W
Rw P or P
Re W or W
Re P or P
SCOH Slot
2
0
4
2
0
3
Re P or P
2
0
2
Re W or W
2
0
1
Rw P or P
BSHR/4 or 1:N
Group 3
Rw W or W
2
0
5
2
0
6
2
0
7
2
0
8
2
0
9
2
1
0
2
1
1
2
1
2
2
1
3
Cable Duct
FAN UNIT
Air Filter
BSHR/4 or 1:N
Group 4
Fig. 66 Protection Groups in a hiT 7070 DC shelf (TR3271EU00TR_0402 Hardware and functionality, 91)
FAN UNIT
PDH Slot
2
0
1
2
0
2
2
0
3
Traffic Slot
Traffic Slot
Traffic Slot
Traffic Slot
3
0
2
3
0
3
3
0
4
3
0
5
SF160G
SF160G
Traffic Slot
Traffic Slot
Traffic Slot
Traffic Slot
Traffic Slot
SCOH Slot
PDH Slot
LSU Slot
LSU Slot
2
0
4
2
0
5
2
0
6
2
0
7
Cable Duct
FAN UNIT
Air Filter
2
0
8
2
0
9
2
1
0
2
1
3
CLU Slot
2
1
2
CLU Slot
LSU Slot
2
1
1
LSU Slot
PDH Slot
LSU Slot
LSU Slot
PDH Slot
LSU Slot
2
1
4
2
1
5
3
0
6
3
0
7
3
0
8
3
0
9
3
1
0
3
1
1
3
1
2
3
1
3
3
1
4
Fig. 67 Sub-rack equipping of SURPASS hiT 7070 SC (TR3271EU00TR_0402 Hardware and functionality, 93)
Traffic Slot
3
0
1
LSU Slot
PDH Prot.
Traffic Slot
BSHR/4 or 1:N
Group 1
Rw P or P
Re W or W
Re P or P
W
SCOH Slot
3
0
5
Rw W or W
3
0
4
SF160G P
Re W or W
3
0
3
SF160G W
Rw P or P
3
0
2
Re P or P
Rw W or W
3
0
1
P
FAN UNIT
Air Filter
CLU P
CLU W
LSU Slot
LSU Slot
LSU Slot
201 202 203 204 205 206 207 208 209 210 211 212 213 214 215
3
0
6
3
0
7
3
0
8
3
0
9
3
1
0
3
1
1
3
1
2
3
1
3
3
1
4
BSHR/4 or 1:N
Group 1
Fig. 68 Protection Groups in a hiT 7070 SC shelf (TR3271EU00TR_0402 Hardware and functionality, 95)
Cable Duct
LSU Slot
LSU Slot
LSU Slot
LSU Slot
LSU Slot
IF2M P
Cable
Duct
MS-COPA
215 LSU
214 LSU
212 LSU
211 LSU
209 LSU
208 LSU
206 LSU
205 LSU
202 ESM-CORE Y
201 ESM-CORE X
112
111
110
109
108
107
106
105
104
103
102
101
MS-AP
Slot numbers
MS-ILANS
Fig. 69 Sub-rack equipping of SURPASS hiT 7070 PDH MicroShelf (TR3271EU00TR_0402 Hardware and functionality, 97)
Fan Unit
201
101
Traffic slot
102
Traffic slot
202
Traffic slot
203
Main Board
103
Traffic slot
In slots 101, 102, 103 and 104 a selection of the following cards can be configured:
Optical STM-4 Interface O622-2/O622C-2
Optical STM-1 Interface O155-2/O155-4
Electrical STM-1 Interface E155-4
Electrical 2 Mbit/s Interface P1-21/P1-42
Electrical 34/45 Mbit/s Interface P3-3
Ethernet Interface E100-4/E100-8/E100S-8
Optical Gigabit Ethernet Interface O1000-4
Fig. 70 Subrack equipping of SURPASS hiT 7050 FP1 (TR3271EU00TR_0402 Hardware and functionality, 101)
MSP 1+1
MSP 1+1
MSP 1+1
MSP 1+1
Fig. 71 SURPASS hiT 7050 FP1 MSP 1+1 traffic protection (TR3271EU00TR_0402 Hardware and functionality, 101)
e
m
p
X t
y
X Y
MicroShelf
X Y
MicroShelf
MicroShelf
1
2
3
LNQ622M
ESM-Core
Extension Link
Fig. 72 Extension link protection scenarios for single PDH MicroShelf (TR3271EU00TR_0402 Hardware and functionality, 103)
1
2
3
LNQ622M
ESM-Core
Extension Link
e
m
p
X t
y
e
m
p
X t
y
MicroShelf
MicroShelf
hiT 7070-DC or -SC
X Y
X Y
X Y
MicroShelf
MicroShelf
X Y
MicroShelf
MicroShelf
Fig. 73 Extension link protection scenarios for dual PDH MicroShelf (TR3271EU00TR_0402 Hardware and functionality, 105)
112
111
110
109
108
107
106
105
104
103
102
101
2
0
9
2
1
1
2
1
2
2
1
3
2
1
4
CLU Slot
2
1
0
CLU Slot
2
0
8
LSU Slot
2
0
7
LSU Slot
2
0
6
PDH Slot
2
0
5
LSU Slot
PDH Slot
2
0
4
LSU Slot
LSU Slot
2
0
3
PDH Slot
LSU Slot
2
0
2
LSU Slot
PDH Slot
2
0
1
LSU Slot
PDH Prot.
FAN UNIT
2
1
5
Fig. 74 SURPASS hiT 7070 SC PDH cabling (TR3271EU00TR_0402 Hardware and functionality, 107)
101
102
103
110
111
112
SU
SU
SU
SU
SU
SU
SU
SU
SU
SU
SU
SU
SU
SU
SU
SU
SU
SU
SU
SU
SU
SU
SU
SU
SU
SU
SU
SU
SU
SU
SU
SU
SU
SU
SU
SU
...
7 x 2 Mbit/s or 1 x 34 Mbit/s
Fig. 75 Numbering scheme of the PDH connectors (TR3271EU00TR_0402 Hardware and functionality, 107)
Fig. 76 Cable ducts in the sub rack and the rack (TR3271EU00TR_0402 Hardware and functionality, 109)
Fig. 77 Sub rack cable duct (sample) (TR3271EU00TR_0402 Hardware and functionality, 109)
Fig. 80 Interface cabling, MFP-1 drawer (TR3271EU00TR_0402 Hardware and functionality, 112)
TIF/Alarms
T3/T4
2 1
UBAT
EOW
Major
Minor
ACO
OK Fault
Power 48/60 V
Fig. 81 SURPASS hiT 7050 FP1: Alarm indications and service connectors (TR3271EU00TR_0402 Hardware and functionality, 117)
ADDRESS
1
UBAT
2
EQUIPMENT-AL COM-AL
3
QF2
Fig. 82 SURPASS hiT 7050 FP1: Network Element Alarm Panel NEAP (TR3271EU00TR_0402 Hardware and functionality, 118)
BATT4
BATT3
CES
QEXT
Q
EOW
CANEX
TIF
AUX 4
AUX 3
AUX 2
AUX 1
T3/T4
BATT2
BATT1
T3/T4
Fig. 83 SURPASS hiT 7050 FP1: Connector Panel COPA (TR3271EU00TR_0402 Hardware and functionality, 118)
Air Filter
201
Fan
Slot 101
Equipped with O155-2
Slot 202
Equipped with P1-21
Slot 102
empty
Slot 203
Slot 103
empty
MFP1
Fig. 84 SURPASS hiT 7050 FP1 subrack (TR3271EU00TR_0402 Hardware and functionality, 119)
FAN UNIT
Air Filter
PF2G5
Empty Slot
Empty Slot
Empty Slot
Empty Slot
CLU P
CLU W
Empty Slot
Empty Slot
Empty Slot
Empty Slot
Empty Slot
Empty Slot
LSU
LSU
2 Mbit/s
LSU
LSU
2 Mbit/s
2 Mbit/s Prot.
FAN UNIT
201 202 203 204 205 206 207 208 209 210 211 212 213 214 215
301 302 303 304 305 306 307 308 309 310 311 312 313 314
Fig. 85 SURPASS hiT 7070 SC subrack (TR3271EU00TR_0402 Hardware and functionality, 121)
Cable Duct
VC-4 Switch P
VC-4 Switch W
IFQGBE
Empty Slot
Empty Slot
Empty Slot
Empty Slot
SF2G5
TIF/Alarms
T3/T4
2 1
UBAT
EOW
Major
Minor
ACO
OK Fault
Power 48/60 V
Fig. 86 SURPASS hiT 7050 FP1: Alarm indications and service connectors (TR3271EU00TR_0402 Hardware and functionality, 127)
ADDRESS
1
UBAT
2
EQUIPMENT-AL COM-AL
3
QF2
Fig. 87 SURPASS hiT 7050 FP1: Network Element Alarm Panel NEAP (TR3271EU00TR_0402 Hardware and functionality, 128)
BATT4
BATT3
CES
QEXT
Q
EOW
CANEX
TIF
AUX 4
AUX 3
AUX 2
AUX 1
T3/T4
BATT2
BATT1
T3/T4
Fig. 88 SURPASS hiT 7050 FP1: Connector Panel COPA (TR3271EU00TR_0402 Hardware and functionality, 128)
Air Filter
201
Fan
Slot 101
Equipped with O155-2
Slot 202
Equipped with P1-21
Slot 102
empty
Slot 203
Slot 103
empty
MFP1
Fig. 89 SURPASS hiT 7050 FP1 subrack (TR3271EU00TR_0402 Hardware and functionality, 129)
FAN UNIT
Air Filter
PF2G5
STM-16/-64 card
STM-16/-64 card
STM-16/-64 card
STM-16/-64 card
CLU P
CLU W
Empty Slot
Empty Slot
Empty Slot
Empty Slot
Empty Slot
Empty Slot
LSU
LSU
2 Mbit/s
LSU
LSU
2 Mbit/s
2 Mbit/s Prot.
FAN UNIT
201 202 203 204 205 206 207 208 209 210 211 212 213 214 215
301 302 303 304 305 306 307 308 309 310 311 312 313 314
Fig. 90 SURPASS hiT 7070 SC subrack (TR3271EU00TR_0402 Hardware and functionality, 131)
Cable Duct
VC-4 Switch P
VC-4 Switch W
IFQGBE
Empty Slot
Empty Slot
Empty Slot
Empty Slot
SF2G5