Vous êtes sur la page 1sur 2

Turbine start up curve in Cold start up

Generator shaft speed

Idle operating rated speed


Automatic speed
increase
1500
Generator rated speed 1500 Rpm

Push turbine rated speed button


Turbine rated speed- 6231 Rpm

Push turbine start button

1000

1st Critical Speed (app-565 rpm)


Turbine between (1880-2590 rpm)
Turning start

500
Idle speed (181 rpm)
Turning speed 750 rpm
Generator voltage established

Time (Min)
0 35 60

Note:- After getting the turbine speed of 750 Rpm allow it run for following cases.
1) In cold condition all it run for 35 Minutes.
2) In warm condition allow it run for 25 Minutes.
3) In Hot condition allow it run for 15 Minutes
03/13/17 08:03 1
Turbine shutdown curve

Generator shaft speed (rpm) Push stop button in generator panel

1500 Emergency stop valve and governor valve closed.


At 95% of turbine speed AOP Auto start and
MOP disengaged.

1000 Turbine stopped Stop turning


Turning start
Stop Aux. lube oil pump
Stop control oil pump Stop E.O.P

Turning recommend approx- 10 hrs

Turning at least 2 hrs


500

AOP at least 2hrs

Turning speed- 12.5 rpm

0 30 630
Time (min)

03/13/17 08:03 2

Vous aimerez peut-être aussi