Lecture Goals
Slender Column Design
One-way and two-way slab
Slab thickness, h
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 2
Design of Long Columns-
Example
A rectangular braced column of a multistory frame
building has floor height lu =25 ft. It is subjected to
service dead-load moments M2= 3500 k-in. on top and
M1=2500 k-in. at the bottom. The service live load
moments are 80% of the dead-load moments. The
column carries a service axial dead-load PD = 200 k
and a service axial live-load PL = 350 k. Design the
cross section size and reinforcement for this column.
Given A = 1.3 and B = 0.9. Use a d=2.5 in. cover
with an sustain load = 50 % and fc = 7 ksi and fy = 60
wood4657@yahoo.es
ksi.
27/04/17 wood4657@gmail.com 3
Design of Long Columns-
Example
Compute the factored loads and moments are 80% of
the dead loads
Pu 1.2 PD 1.6 PL 1.2 200 k 1.6 350 k
800 k
M 1u 1.2 M D 1.6 M L 1.2 2500 k-in 1.6 0.8 2500 k-in
6200 k-in.
M 2u 1.2M D 1.6 M L 1.2 3500 k-in 1.6 0.8 3500 k-in
8680 k-in.
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 4
Design of Long Columns-
Example
Compute the k value for the braced compression
members
k 0.7 0.05 A B 0.7 0.05 1.3 0.9
0.81 1.0
k 0.85 0.05 min 0.85 0.05 0.9
0.895 1.0
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 5
Design of Long Columns-
Example
Check to see if slenderness is going to matter. An
initial estimate of the size of the column will be an inch
for every foot of height. So h = 25 in.
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 7
Design of Long Columns-
Example
Compute components of concrete
f c 33 150
1.5
Ec 33w 1.5
7000
5.07x106 psi 5.07x103 ksi
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 8
Design of Long Columns-
Example
Compute the stiffness, EI
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 9
Design of Long Columns-
Example
The critical load (buckling), Pcr, is
EI
2 2 4.4x107 k-in 2
Pcr
klu
2 2
12 in.
0.81 25 ft ft
7354.3 k
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 10
Design of Long Columns-
Example
Compute the coefficient, Cm, for the magnification
coefficient
M 1
Cm 0.6 0.4
M 2
6200 k-in.
0.6 0.4 0.89 0.4
8680 k-in.
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 11
Design of Long Columns-
Example
The magnification factor
Cm 0.89
ns
Pu 800 k
1 1
0.75Pcr 0.75 7354.3 k
1.04 1.0
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 12
Design of Long Columns-
Example
The design moment is
As 7.0 in 2
Acs 7.0 in 2
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 14
Design of Long Columns-
Example
The column is compression controlled so c/d > 0.6.
Check the values for c/d = 0.6
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 15
Design of Long Columns-
Example
Check the strain in the tension steel and compression
steel.
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 16
Design of Long Columns-
Example
The tension steel is
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 17
Design of Long Columns-
Example
Combined forces are
Pn Cc Cs1 T
1405.7 k 378.35 k 406.0 k
1378.05 k
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 19
Design of Long Columns-
Example
Moment is
h a h h
M n Cc Cs1 d T d
2 2 2 2
9.45 in.
1405.7 k 12.5 in.
2
378.35 k 12.5 in. 2.5 in.
406.0 k 22.5 in. 12.5 in.
18773 k-in.
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 20
Design of Long Columns-
Example
The eccentricity is
M n 18773 k-in
e
Pn 1378.05 k
13.62 in.
Since the e = 11.28 in. < 13.62 in. The section is in the
compression controlled region = 0.65. You will want
to match up the eccentricity with the design.
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 21
Design of Long Columns-
Example
We need to match up the eccentricity of the problem.
This done varying the c/d ratio to get the eccentricity
to match. Check the values for c/d = 0.66
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 22
Design of Long Columns-
Example
Check the strain in the tension steel and compression
steel.
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 23
Design of Long Columns-
Example
The tension steel is
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 24
Design of Long Columns-
Example
Combined forces are
Cc 0.85 f cba 0.85 7 ksi 25 in. 10.395 in.
1545.26 k
Cs1 Acs f cs 0.85 f c 7 in 2 60 ksi 0.85 7 ksi
378.35 k
T As f s 7 in 2 44.82 ksi
313.74 k
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 25
Design of Long Columns-
Example
Combined force is
Pn Cc Cs1 T
1546.26 k 378.35 k 313.74 k
1610.9 k
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 26
Design of Long Columns-
Example
Moment is
h a h h
M n Cc Cs1 d T d
2 2 2 2
10.395 in.
1545.26 k 12.5 in.
2
378.35 k 12.5 in. 2.5 in.
313.74 k 22.5 in. 12.5 in.
18205.2 k-in
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 27
Design of Long Columns-
Example
The eccentricity is
M n 18205.2 k-in
e
Pn 1610.9 k
11.30 in.
Since the e 11.28 in. The reduction factor is equal to
= 0.65. Compute the design load and moment.
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 28
Design of Long Columns-
Example
The design conditions are
Pu Pn 0.65 1610.9 k
1047.1 k 800 k OK!
M u M n 0.65 18205.2 k-in
11833.4 k-in. 9027.2 k-in. OK!
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 30
Using Interaction
Diagrams
Determine eccentricity. Select steel sizes.
Estimate column size Check values.
required base on axial load. Design ties by ACI code
Determine e/h and required Design sketch
Pn/Ag, Mn/(Agh)
Determine which chart to use
from fc, fy and . Determine
from the chart.
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 31
Two-way Slabs
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 32
Comparison of One-way and
Two-way slab behavior
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 33
Comparison of One-way and
Two-way slab behavior
One-way and two-way
slab action carry load
in two directions.
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 35
Comparison of One-way and
Two-way slab behavior
For flat plates and slabs the column connections
can vary between:
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 36
Comparison of One-way and
Two-way slab behavior
Fast
Disadvantages
Low shear capacity
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 39
Comparison of One-way and
Two-way slab behavior
Economic Choices
Flat Slab suitable span 20 to 30 ft with LL= 80 -150 psf
Advantages
Low cost formwork
Fast
Disadvantages
Need more formwork for capital and panels
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 40
Comparison of One-way and
Two-way slab behavior
Economic Choices
Waffle Slab suitable span 30 to 48 ft with LL= 80
-150 psf
Advantages
Carries heavy loads
Fast
Disadvantages
Formwork with panels is expensive
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 41
Comparison of One-way and
Two-way slab behavior
Economic Choices
One-way Slab on beams suitable span 10 to 20 ft with
LL= 60-100 psf
Can be used for larger spans with relatively higher
relative low
Expensive formwork expected.
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 42
Comparison of One-way and
Two-way slab behavior
ws =load taken by short direction
wl = load taken by long direction
A = B
5ws A4 5wl B 4
384 EI 384 EI
ws B4
For B 2A ws 16wl
wl A4
Rule of Thumb: For B/A > 2,
design as one-way slab
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 43
Two-Way Slab Design
Static Equilibrium of Two-Way Slabs
l22
Total Moment in both beams M wl1 k - ft
8
Full load was transferred east-west by the planks and then was
transferred north-south by the beams;
The same is true for a two-way slab or any other floor system.
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 46
General Design
Concepts
(1) Direct Design Method (DDM)
Limited to slab systems to uniformly distributed
loads and supported on equally spaced columns.
Method uses a set of coefficients to determine the
design moment at critical sections. Two-way slab
system that do not meet the limitations of the ACI
Code 13.6.1 must be analyzed more accurate
procedures
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 47
General Design
Concepts
(2) Equivalent Frame Method (EFM)
A three-dimensional building is divided into a
series of two-dimensional equivalent frames by
cutting the building along lines midway between
columns. The resulting frames are considered
separately in the longitudinal and transverse
directions of the building and treated floor by
floor.
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 48
Equivalent Frame Method
(EFM)
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 49
Equivalent Frame Method
(EFM)
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 50
Method of Analysis
(1) Elastic Analysis
Concrete slab may be treated as an elastic
plate. Use Timoshenkos method of analyzing
the structure. Finite element analysis
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 51
Method of Analysis
(2) Plastic Analysis
The yield method used to determine the limit state of
slab by considering the yield lines that occur in the
slab as a collapse mechanism.
The strip method, where slab is divided into strips
and the load on the slab is distributed in two
orthogonal directions and the strips are analyzed as
beams.
The optimal analysis presents methods for
minimizing the reinforcement
wood4657@yahoo.es based on plastic
analysis
27/04/17 wood4657@gmail.com 52
Method of Analysis
(3) Nonlinear analysis
Simulates the true load-deformation characteristics
of a reinforced concrete slab with finite-element
method takes into consideration of nonlinearities of
the stress-strain relationship of the individual
members.
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 53
Column and Middle
Strips
The slab is broken
up into column
and middle strips
for analysis
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 54
Minimum Slab Thickness for
Two-way Construction
The ACI Code 9.5.3 specifies a minimum slab thickness
to control deflection. There are three empirical
limitations for calculating the slab thickness (h), which
are based on experimental research. If these limitations
are not met, it will be necessary to compute deflection.
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 55
Minimum Slab Thickness for
Two-way Construction
(a) For 0.2 m 2
fy
ln 0.8
200,000
h
36 5 m 0.2
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 56
Minimum Slab Thickness for
Two-way Construction
(b) For 2 m
fy
ln 0.8
200,000
h
36 9
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 57
Minimum Slab Thickness for
Two-way Construction
(c) For m 0.2
Use the following table 9.5(c)
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 58
Minimum Slab Thickness for
Two-way Construction
Slabs without interior
beams spanning
between supports and
ratio of long span to
short span < 2
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 59
Minimum Slab Thickness for
two-way construction
The definitions of the terms are:
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 60
Definition of Beam-to-Slab
Stiffness Ratio,
Accounts for stiffness effect of beams located along
slab edge reduces deflections of panel
adjacent to beams.
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 61
Definition of Beam-to-Slab
Stiffness Ratio,
4E cb I b / l E cb I b
4E cs I s / l E cs I s
E cb Modulus of elasticity of beam concrete
E sb Modulus of elasticity of slab concrete
I b Moment of inertia of uncracked beam
I s Moment of inertia of uncracked slab
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 63
Beam and Slab Sections for
calculation of
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 64
Beam and Slab Sections for
calculation of
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 66
Example - Slab
A flat plate floor system with
panels 24 by 20 ft is supported on
20 in. square columns.
Determine the minimum slab
thickness required for the interior
and corner panels. Use fc = 4 ksi
and fy = 60 ksi
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 67
Example - Slab
Slab thickness, from table 9.5(c) for fy = 60 ksi
and no edge beams
ln
hmin
30
20 in. 1 ft.
ln 24 ft. 2 22.33 ft.
2 12 in.
12 in.
22.33 ft.
hmin 1 ft. 8.93 in. 9 in.
30
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 68
Example - Slab
Slab thickness, from table 9.5(c) for fy = 60 ksi
and no edge beams for = m = 0 (no beams)
ln
hmin
33
12 in.
22.33 ft.
hmin 1 ft. 8.12 in. 8.5 in.
33
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 69
Example
Calculations
The floor system consists of
solid slabs and beams in two
directions supported on 20-in.
square columns. Determine the
minimum slab thickness, h,
required for the floor system.
Use fc = 4 ksi and fy = 60 ksi
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 70
Example
Calculations
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 71
Example
Calculations
To find h, we need to find m therefore Ib, Islab and for
each beam and slab in long short direction. Assume
slab thickness h = 7 in. so that x = y < 4 tf
22 in. 7 in. 15 in. 4tf 4 7 in. 28 in.
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 72
Example
Calculations
Compute the moment of inertia and centroid
I beam 22453 in 4
1 3 1 12 in.
7 in.
3
I slab bh 20 ft
12 12 1 ft.
6860 in 4
b h Ai (in2) y i (in) y iAi (in3) I (in4) d (in) d2A (in4)
Flange 7 46 322 3.5 1127 1314.833 -4.69751 7105.442
Beam 15 16 240 14.5 3480 4500 6.302491 9533.135
ybar = 8.197509 in
wood4657@yahoo.es
I = 22453.41 in4
27/04/17 wood4657@gmail.com 73
Example
Calculations
Compute the coefficient for the long direction
EI beam 22453 in 4
long 4
EI slab 6860 in
3.27
Short side of the moment of inertia
1 3 1 12 in.
7 in.
3
I slab bh 24 ft
12 12 1 ft.
8232 in wood4657@yahoo.es
4
27/04/17 wood4657@gmail.com 74
Example
Calculations
Compute the coefficient for short direction
EI beam 22453 in 4
short
EI slab 8232 in 4
2.73
The average m for an interior panel is
2 long 2 short 2 3.27 2 2.73
avg
4 4
3.0 wood4657@yahoo.es
27/04/17 wood4657@gmail.com 75
Example
Calculations
Compute the coefficient
20 in. 1 ft.
24 ft. 2
llong 2 12 in.
1.22
lshort 20 in. 1 ft.
20 ft. 2
2 12 in.
Compute the thickness for m > 2
fy 12 in.
60000
ln 0.8 22.33 ft. 0.8
200000
1 ft.
200000
h
36 9 36 9 1.22
wood4657@yahoo.es
6.28 in. Use slab thickness, 6.5 in. or 7 in.
27/04/17 wood4657@gmail.com 76
Example
Calculations
Compute the moment of inertia and centroid for the
L-beam
I L-beam 15302 in 4
1 3 1 12 in.
7 in.
3
I slab bh 10 ft
12 12 1 ft.
3430 in 4
b h Ai (in2) y i (in) y iAi (in3) I (in4) d (in) d2A (in4)
Flange 7 27 189 3.5 661.5 771.75 -5.36585 5441.761
Beam 15 12 180 14.5 2610 3375 5.634146 5713.849
ybar = 8.865854
wood4657@yahoo.es in
27/04/17 wood4657@gmail.com
I = 15302.36 in4 77
Example
Calculations
Compute the m coefficient for long direction
EI L-beam 15302 in 4
long 4
EI slab 3430 in
4.46
Short side of the moment of inertia
1 3 1 12 in.
7 in.
3
I slab bh 12 ft
12 12 1 ft.
4116 in wood4657@yahoo.es
4
27/04/17 wood4657@gmail.com 78
Example
Calculations
Compute the m coefficient for the short direction
EI L-beam 15302 in 4
short 4
EI slab 4116 in
3.72
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 79
Example
Calculations
Compute the m coefficient for the edges and corner
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 81
Example
Calculations
Compute the largest length ln of the slab/beam, edge to
first interior column.
20 in. 1 ft.
12 in.
1 ft.
ln 24 ft.
2 12 in. 2 12 in.
22.67 ft.
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 82
Example
Calculations
Compute the thickness of the slab with m > 2
fy 12 in.
60000
ln 0.8 22.67 ft. 0.8
200000
1 ft.
200000
h
36 9 36 9 1.22
6.37 in. Use slab thickness, 6.5 in. or 7 in.
wood4657@yahoo.es
27/04/17 wood4657@gmail.com 83