Distribution study
A technique which is able
to identify, on-line, the
distribution of fluids, both
liquids and gases, within
process vessels whilst
having no impact on the
process or production rate.
TRACERCO DiagnosticsTM
Distribution study
Technology
Utilises advanced tracers
Active
Gaseous, organic & aqueous
Short half-life
Hand held inspection equipment
Density measurement
Gamma absorption
Grid scanning
TRACERCO DiagnosticsTM
Distribution study
Features of technique
Tracer technology
Active tracer
Phase specific
No effect on process
Injected into process
Suitable for liquid and gas systems
All vessel types and diameters
External detectors
Typically 4 per ring
Immediate results
TRACERCO DiagnosticsTM
Distribution study
Features of technique
Tracer technology
Density measurement
Grid scans
Typically 4
Suitable for liquid systems
Limited by vessel diameters &
packing density
Non-intrusive inspection
No vessel preparation
Immediate results
TRACERCO DiagnosticsTM
Distribution study
Technique can identify
Process issues
Fluid mal-distribution
Fluid channelling
Mechanical issues
Packing failure
Collapse
Damage
Distributor failure
Poor distribution
Total failure
TRACERCO DiagnosticsTM
Distribution study
Benefits of technique
Increase production capacity
Identify optimal process conditions on-
line
Identify extra capacity available
Reduce shutdown costs
Know problem before shutdown
Reduce cost of replacement
Reduce shutdown time
Avoid shutdown
On-line process modifications
TRACERCO DiagnosticsTM
Distribution study
Case study 1 - Packed bed column - UK
Problem
Packed bed column
3 meter diameter
Fluctuating pressure drop
Suspected blockages
Options
Shut-down vessel
Inspect, order new material
Shutdown again to replace
Carry out TRACERCO DiagnosticsTM Distribution
study on-line
TRACERCO DiagnosticsTM
Distribution study
Case study 1 - Packed bed column - UK
Study NORTH
Density measurement
Gamma absorption
EAST
4 grid scan
North, South, East, West
WEST
Hand held equipment
Two man team
SOUTH
TRACERCO DiagnosticsTM
Distribution study
Case study 1 - Packed bed column - UK
Results
High mean density 100000
MAL-DISTRIBUTION THROUGH PACKED
Fig.1 BED
R a d ia tio n I n te n s ity ( c o u n ts /3 s e c )
High liquid flow 10000
Support
Diagnosis
100
0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 7.5 8
Distance (metres)
EAST WEST NORTH SOUTH
Vessel shutdown
R a d ia tio n I n te n s ity ( c o u n ts /3 s e c )
Distributor replaced 10000
Support
N/E
Injection
Point
S/E
Ring 1
N/W
S/
W
Two Rings of Four Ring 2
Detectors as shown
above. Located at top
and bottom of catalyst
bed, as shown.
TRACERCO DiagnosticsTM
Distribution study
Case study 2 - Catalyst bed - SE Asia
Results
100
90 Top N/W
Top N/E
80 Top S/E
Radiation Intensity
60
High flow 50
30
10
60
Diagnosis
S/W
Radiation Intensity
30
Throughout vessel 10
0
0 5 10 15 20 25 30 35 40
Time (seconds)
TRACERCO DiagnosticsTM
Distribution study
Case study 2 - Catalyst bed - SE Asia
Outcome
Damaged distributor to blame
Replaced
New catalyst charge
Process performance returned
TRACERCO DiagnosticsTM
Distribution study
A technique which is able
to identify, on-line, the
distribution of fluids, both
liquids and gases, within
process vessels whilst
having no impact on the
process or production rate.