Académique Documents
Professionnel Documents
Culture Documents
www.sendig.com 1
An Overview of the
Steps
1. Collecting Machine data
2. Preparing Instrument & Sensor
3. Balancing really required ?
4. Balancing possible ?
5. Procedure of balancing
www.sendig. 2
Step 1 - Collecting Machine
data
Understand the machine to be
balanced as much as possible
Collect machine data
Take a photo of the machine
www.sendig. 3
Sample: Machine to be balanced
Impeller Parameter:
Diameter: 1400mm
Thickness: 500mm
Bearing1 Bearing2 Blade Number: 12
Material:Fiberglass-
Impeller
Reinforced
Plastics
RPM: 1825 r/min
Bearing Model: ?
Motor Parameter:
Power: 75kW
RPM: 1500 r/min
Motor
Others:
Belt transmission
Spring base
Manufacture: LG
Step 2 - Preparing Instrument &
Sensors
Sendig-904/907 dual-channel
data collector/analyser/balancer
A notebook computer
Sendig-MCM3 Analysis Software
www.sendig. 5
Sensors & Cable connecting
Attach
reflecting
paper on shaft
www.sendig. 6
Step 3 - Balancing really
required ?
Use 904/907 to measure overall vibration values
Compare with ISO Standard
www.sendig. 7
Horizontal VELOCITY is the critical parameter
6: Point: Motor-1-Side-2-X
Alarm-mode: Displacement
Freq-Range: 500Hz
Sensor:4.6
New Data Old Data
ACC xxx / xxx m/s2
VEL 7.2 / 2.1 mm/s
DISP 68 / 12 m
ENV xx / xx m/s2
www.sendig. 8
Comparison with ISO2372
Sample
www.sendig. 10
Sample
Not Permissible, Balancing really required !
Measurement
9.95
mm/s
Step 4-1: Balancing possible?
single peak spectrum ?
www.sendig. 13
Sample of non-single peak spectrum- Better change bearing before ba
www.sendig. 14
Sample of single peak spectrum
You can reduce the vibration by Balancing
www.sendig. 15
Step 4-2: Balancing possible ?
90o phase
difference ? measure vibration phase difference
Use 904/907 to
Phase Measurement:
Since phase difference is not 90o nor closer to 90o ,this means the
problem with the fan is something else other than unbalance.
www.sendig. 17
Sample
Sample of nearly 90o phase difference
You can reduce the vibration by Balancing
1. Phase stable
2. Phase Measurement:
Vertical: 0.693 73
Phase
Horizontal: 1.569 150 difference is
77o
www.sendig. 18
Balancing Training Part 2
Procedure of balancing
www.sendig. 19
Different Kinds Of
Imbalance
1-plane 2-plane
imbalance imbalance
www.sendig. 20
Characteristics Of
Imbalance
1. The vibration frequency is mainly composed of
RPM frequency. For each round the rotor turns, a
vibration is occurred.
2. The wave is an approximate sine wave.
3. There is a difference of 90o between the vertical
vibration phase and the horizontal one.
4. With RPM increasing, the vibration amplitude is
increased
www.sendig. 21
Basic Principle
Of 1 Plane Balancing
1 select a plane to fix trial mass and a
point to measure, draw scale of phase
and sign of 0o phase
2 measure initial vibration A0(phase
and amplitude)
draw A0 & A1, calculate A1- A0
measure the angle between A1- A0
o K and A0
turn Q a along the direction of ,
Q gain the correct location of balancing
P mass.
A1- A0 the weight of balancing mass is as
the following : P Q A0
A1 A
0 A1 A0
o
www.sendig. 23
Method of Influence
Coefficients
Method of influence coefficients is
widely used, its step as the following
(1 plane balancing as example):
www.sendig. 24
IF THE INFLUENCE COEFFICIENTS ARE KNOWN,
THE STEP OF FIXING TRIAL MASS ARE IGNORED
www.sendig. 25
NOTICES DURING THE
OPERATION
reverse to the
direction of rotation
www.sendig. 26
SELECTING PARAMETERS
www.sendig. 27
CONFIRM whether the trial is
suitable
before and after trial value difference<25% value difference>25%
phase difference>25 ok ok
Without
influence
Tacho
sensor
coefficients
A
Accelerometer
907
www.sendig. 29
Operation Basic
Prompt is displayed at the last line
Press and key to move the cursor
up and down
Press Enter to select iterm
Press number keys to input digits
To other MENU, press PgDn or PgUp
www.sendig. 30
Always make sure the
Setting is correct before
the balancing Enter a digit, select 1 set of data from 10
Change by ENTER,
use displacement or
velocity for most machines
Input sensitivity (from
accelerometer certificate)
www.sendig. 31
INITIAL MEASUREMENT
Press Enter to measure
rotation speed first
Press Enter for a moment
to measure vibration after
rotation speed become
steady
After phase and amplitude
become steady, press
Enter for a moment to end
the measurement
www.sendig. 32
TRIAL ESTIMATION
Input the 4
parameters
When cursor on 6th
line, press Enter to
calculate trial range
Stop the machine, fix
a trial mass according
to the range
www.sendig. 33
TRIAL MEASUREMENT
Input phase and weight of the
trial, confirm whether it will be
removed afterward, restart the
machine
Move cursor to 6th line, press
Enter to measure rotation speed
When RPM steady, press Enter a
moment to measure vibration
When amplitude and phase
steady, press Enter for a
moment to end the
measurement
www.sendig. 34
TRIAL RESULT
See what the 6th line
shows
If YES displayed, press
Pg Dn to go on
If NO displayed, stop
the machine, adjust
trial mass, return to
the early page of TRAIL
MEASUREMENT,
measure again
www.sendig. 35
CALCULATION
Cursor on 2nd line, press ENTER to Cursor on 2nd line, press Enter
calculate influence coefficients to calculate balancing mass
The result is shown in 4th line The result is shown in 3rd line
www.sendig. 36
Decomposing/Splitting
Input the 2 angles
Display the results
If nothing displayed
at right side, change
the order of the 2
angles and re-enter Pa2
Pa
Pa1
www.sendig. 37
VERIFICATION
Cursor on 2nd line, press
Enter to measure rotation
speed
When RPM steady, press
Enter a moment to measure
vibration
When amplitude and phase
steady, press Enter for a
moment to end the
measurement
The last 2 lines displays the
results
www.sendig. 38
1-PLANE BALANCING
With influence coefficients,
you do not need to add trial
mass. You need only
measure the initial vibration
www.sendig. 39
SETTING PARAMETERS
www.sendig. 40
INITIAL MEASUREMENT
Press Enter to measure
rotation speed
Press Enter for a moment
to measure vibration after
rotation speed become
steady
When phase and
amplitude become steady,
press Enter for a moment
to end the measurement
www.sendig. 41
INPUT COEFFICIENTS
www.sendig. 42
Calculation, Decomposition &
verification
calculate
balancing mass
Decomposition
and verification
are the same as Pa2
illustrated earlier
Pa
www.sendig. Pa1 43
2-PLANES BALANCING
Without influence coefficients
The main difference than 1-plane:
1. Need to add trial mass one after
another at the 1st plane and 2nd plane
2. Need to use 2 vibration sensors
www.sendig. 44
Sensors & Cable connecting
Attach
reflecting
paper on shaft
www.sendig. 45
SETTING PARAMETERS
www.sendig. 46
INITIAL MEASUREMENT &
TRIAL ESTIMATION
Get 2
lines of
reading
here
www.sendig. 47
TRIAL I MEASUREMENT
Input phase
and weight of
the trial on
plane 1,
decide if it
will be
removed,
restart the
machine
www.sendig. 48
TRIAL II MEASUREMENT
Input phase
and weight of
the trial on
plane 2,
decide if it
will be
removed,
restart the
machine
www.sendig. 49
Calculation, Decomposition &
Verification
calculate
balancing mass
Decomposition
and verification
are the same as
illustrated
earlier Pa2
Pb2
www.sendig. Pa Pb Pb150
2-PLANES BALANCING
With influence coefficients
With influence
coefficients, you do not
need to add trial mass.
You need only measure
the initial vibration.
www.sendig. 51