LOGIN TO iPasolink Equipment.
Click on Setup
to start
configuration.
NE Name
In Radio configuration
Menu, Click on Setup
ODU Information:
Make sure that ODU information is not invalid here. If it is invalid check ODU
power, IF cable, IF Connectors etc.
Click on desired link MODEM slot and set the power as per link
budget..
Metering:
Click on Metering->
Current Metering
Click on MODEM to
check the RSL change
during Alignment.
Comments:
After aforementioned steps we can start the alignment.
Keep watching RSL at Metering and lock the antennas at more than 3db of
required RSL given in link budget.
NMS Configuration for Root NE:
Set IP, Subnet Mask and GW as per given DCN plan and check
connect NMS port to NMS to yes for root NE which is
connected with NEC server through router.
General Setting (Detailed)
Set Inband
Management to
not used
Service Status
Summary. Should
be same as here.
SNMP Setting.
Click on SNMP
and enable SNMP
V1, SNMP V3.
Set UDP port to
161.
SNMP Community
Click on SNMP
Community and set:
Community Name:
public
Access Level: Admin.
Access Control: Enable
Service IP Address:
0.0.0.0
Subnet Mask:
255.255.255.255
SNMP Trap Entry and NTP
SNMP Trap Entry
: No change.
NTP Should be in
Running Status
and parameters
should be same
as given here.
NTP Server Address and FTP
SNMP Service
Address : No
change.
FTP Should be in
Running Status
and parameters
should be same
as given here.
SFTP, HTTP and HTTPS SFTP : Stopped
HTTP: Running
and TCP port is
80.
HTTPS: Stopped
Ethernet Function Setting:
Click on Bridge
Setting and then
click on Modify .
Bridge Setting:
Set Aging On
FDB Aging
Time:300s
GbE Max Frame
Size: 2000 bytes
FE Max Fame
Size:1522bytes
Vlan Mode:802.1Q
(Mandatory)
Default VLAN ID1
Default VLAN TPID:
8100
Normal NE NMS Configuration:
Set Inband
Management to
not used
If Ethernet port
enabled its speed
should be set
auto.
VLAN Creation: Example: Site MMN012-MMN008-MMN751_BSC
We want to create
VLAN for ZTE
SDR. First we
enable eth port-1
for SDR. Set the
station ID in port
name.
VLAN Setting: Example site:MMN012
As there are two IDU on MMN008 station and our example link is in
second IDU but the link with BSC is in first IDU. Therefore we use
Ethernet Ports and a physical LAN cable between two IDUs. So we
assign VLAN to eth port02 which is connected with first IDU.
MMN008 facing MMN751 IDU.
Assignment of
VLAN of
MMN012
coming from
other IDU via
eth port.
Assignment of
VLAN of
MMN012 to
the link facing
BSC_MMN75
1.
BSC Site MMN751
Assign the
VLAN of
MMN012 to
Modem Port
MMN008--
MMN751.
VLAN Assignment to LAG Ethernet Group:
Use this setting for Root NE. Root NE is always master and
all other NEs are salve in iPaso Network.
Equipment Clock Setting: Slave
Click on QoS/
Classification
Setting.
Click on
classification
mode.
Equipment Based QoS Mode:
Set Equipment
Based QoS
mode.
Select Profile No.
Click on
Select Profile
No.
Profile 0.
Select the
profile no 0
to set planned
QoS
parameters.
Profile 0 configuration:
Select the
profile no 0
to set planned
QoS
parameters.
Click on entry
1 to set the
Priority.
Note: By default
required setting
for Profile 0 is
available in
iPasolink. No
need to change
profile 0
setting.
Profile 1 Configuration.
Select the
profile no 1
to set planned
QoS
parameters.
Click on entry
1 to set the
Priority.
Profile 1 Setting:
Click on entry
no one by one
as per
required
entries and set
classify
priorities.
Ingress Setting: