Vous êtes sur la page 1sur 10

Test results for mcRNC IP Connectivity with

Juniper EX-4500 with static routing+BFD without


VRF´s

January, 2011

For internal use


1 © Nokia Siemens Networks Presentation / Author / Date
Introduction

 The purpose was to test the failover times for the interface between the mcRNC
and Juniper EX-4500 site switches
 Tests performed in Espoo Säteri lab for
• Management traffic (OAM)
• Iu/Iur user plane traffic (UP)
• Iub traffic control plane traffic (CP)
• Iub traffic OAM WBTS

 RNC 454 R_QN10.1.48.1.10


 Junos 10.3R2.11

For internal use


2 © Nokia Siemens Networks Presentation / Author / Date
Summary

 Separate LAN port used for management connectivity


 CP uses vlan addresses (except iub cp) and in user plane loopback addresses are
in use
 User plane and iub CP addresses can switch over to another EIPU within EIPU pair

For internal use


3 © Nokia Siemens Networks Presentation / Author / Date
Environment mcRNC-454
mcRNC BCN0# MGW
MSS SGSN

CFPU 0
LAN 1

SFP+#1 mcRNC-EX-4500-1
SFP+#2

Iu-CS-CP-1 SFP#7
Iu-CS-UP
Iub
SFP#8 1588v2
Gig 0/2
EIPU 0
IU-BC Gig 0/3 master
OAM WBTS Gig 0/4
Iu-CS-CP-2 GigE
Gig 0/5
1/1
GigE
Gig 0/6
1/2

Iu-PS-CP-1 SFP#15 ISN/GGSN


Iu-PS-CP-2 SFP#16 L3
IUR-CP1 Ge-0/0/0
EIPU 2

IUR-CP2
IUR-UP
IU-PS-UP
IU-PC

A1_OSR1
mcRNC BCN1#
CFPU 1

LAN 1 Gig 0/1


Gig 0/2 L3
SFP+#1
SFP+#2
GigE
Gig 0/3
GigE
1/1
Gig 0/4
1/2
A1_OSR2
Iu-CS-CP-1 SFP#7
Gig 0/5
Gig 0/6
Ge-0/0/0 nodeB 86
Iu-CS-UP SFP#8
Iub
EIPU 1

IU-BC
OAM WBTS
IU-CS-CP-2

Iu-PS-CP-1 SFP#15
Sw_iub_3750
Iu-PS-CP-2 SFP#16
IUR-CP1
EIPU 3

IUR-CP2
IUR-UP nodeB 87
IU-PS-UP
IU-PC
mcRNC-EX-4500-2

For internal use


4 © Nokia Siemens Networks Presentation / Author / Date
BCN management LAN: O&M traffic.
Initial connection
Link failure
BCN#0 CFPU unit failure
EX-4500-1
A1_OSR1
LAN 1

LAN 2
Test PC

BCN#1

LAN 1

LAN 2
A1_OSR2
EX-4500-2

Test case Failover time in seconds Comments

Link failure of BCN#0 CFPU LAN 335 msec SSH to loopback remains
1 interface to EX-4500-1 connected

CFPU unit failure 8 msec Fshascli –WnF /SSH


SSH connection breaks
Node failure of EX-4500-1 345 msec down Request system reboot
1640msec up SSH remains connected

For internal use


5 © Nokia Siemens Networks Presentation / Author / Date
BCN EIPU: Iu-CS CP traffic. Test PC connected to
backbone router CP primary
CP secondary

BCN#0 EX-4500-1 A1-OSR-1


EIPU-0
#7
#8
Test PC

EIPU-2
#15
#16

BCN#1
EIPU-1 #7
#8

EIPU-3 EX-4500-2 A1-OSR-2


#15
#16

CP application Vlan interface addresses are used. Similar


association link set with two primary and two secondary addresses
used in Iu-CS, Iu-PS and Iur

Test case Failover time in seconds Comments

Test cases not applicable, SCTP


multihoming takes care of
redundancy.

For internal use


6 © Nokia Siemens Networks Presentation / Author / Date
BCN EIPU: Iu-CS UP traffic. Test PC connected to
backbone router Initial connect
link failure
EIPU unit failure
BCN#0 EX-4500-1 Juniper EX-4500 failure
EIPU-0
#7
#8

Test PC
Application IP EIPU-2
#15
#16

BCN#1
EIPU-1 #7
#8

EIPU-3 EX-4500-2
#15
#16

UP application IPv4 loopback interface (10.16.225.190) used in test.

Test case Failover time in seconds Comments

Link failure of BCN#0 EIPU-0 220 msec Calls remain established


interface to EX-4500-1

EIPU unit failure (switchover Fshascli –wn /QNUP-0 (normal


manually) 6msec switchover)
Node failure of Cisco EX-4500-1 216msec down Request system reboot
up 4120 msec

For internal use


7 © Nokia Siemens Networks Presentation / Author / Date
BCN EIPU: Iub CP/UP traffic. Test PC connected to Initial connect
3750 switch link failure
EIPU unit failure
BCN#0 EX-4500-1 Juniper EX-4500
EIPU-0
#7
#8
failure

Application IP EIPU-2
#15
#16

VRRP
Test PC
BCN#1
EIPU-1 #7
#8 3750-sw-iub

EIPU-3 EX-4500-2
#15
#16

CP application IPv4 loopback interface used in test. Both EIPU´s


have their own loopback addresses.

Test case Failover time in seconds Comments

Link failure of BCN#0 EIPU-0 226 msec


interface to EX-4500-1

EIPU unit failure (switchover 9msec Fshascli –wn /QNIUB-0 (normal


manually) switchover)
Node failure of Cisco EX-4500-1 45 msec Request system reboot
3296 msec up

For internal use


8 © Nokia Siemens Networks Presentation / Author / Date
BCN EIPU: Iub WBTS OAM. Test PC connected to Initial connect
3750 switch link failure
CFPU unit failure
BCN#0 EX-4500-1 Juniper EX-4500
EIPU-0
#7
#8
failure
CFPU-0

EIPU-2
#15

169.254.0.0/24
#16
Test PC
App VRRP
.19 .13
IP
BCN#1 EIPU-1 #7 3750-sw-iub
#8
CFPU-1

EIPU-3 EX-4500-2
#15
#16

IUB WBTS loopback routed via EIPU´s to CFPU´s. Virtual


addresses .19 and .13 follow IUB-UP and IUB WBTS loopbacks

Test case Failover time in seconds Comments

Link failure of BCN#0 EIPU-0 46 msec


interface to EX-4500-1

CFPU unit failure (switchover 2 msec Fshascli –wnF /QNOMU


manually)
Node failure of Cisco EX-4500-1 59 msec down Request system reboot
2954 up

For internal use


9 © Nokia Siemens Networks Presentation / Author / Date
Configurations

For internal use


10 © Nokia Siemens Networks Presentation / Author / Date

Vous aimerez peut-être aussi