Vous êtes sur la page 1sur 62

Valves

Leak by is evident at this blocked gate valve


• Leakage detection
*>251.6°C

250.0
240.0
230.0
220.0
210.0
200.0
190.0
180.0
170.0
160.0

*<154.5°C

Amorphous heating on left (“cold”) side of valve


indicates leakage
www.flir.com
Hot Compressor Valve

www.flir.com
More Leaking Relief Valves

www.flir.com
Steam Traps

Steam Trap
In-operative

FSI
www.flir.com
Steam Traps
Steam Trap
Operating properly

FSI
www.flir.com
Roof Moisture Leak
Detection

www.flir.com
Wet Insulation - Due to leaking
Steam Tracing

www.flir.com
Studs in a wall (Insulation)

www.flir.com
Fin Fan Exchangers

www.flir.com
Fouling and sediment build up in
exchangers, chillers, and
condensers

www.flir.com
A Look at process flow in a heat exchanger
Water on the tube side and fouling in the bottom left bell head
Process flow on the shell side

www.flir.com
Wet Insulation - Blanket is saturated with water due to leak in
steam tracing. Generalized corrosion and isolated pitting to
.220” was found on this carbon steel line after the insulation was
removed. This type of corrosion usually occurs over a long period
of time

www.flir.com
Steam Leak is clearly visible. It may be a
good idea to strip and inspect this area

www.flir.com
UIC - Under insulation corrosion
The stiffening rings on these pressure vessels are saturated with water.
Typically weep holes are drilled through the center of these steel T-beams to allow the water to
drain. Over years these holes become plugged with oxidized metal and insulation debris.
Corrosion begins slowly then accelerates. I have personally found vessels completely holed
through or corroded through to the internal cladding. Scaffolding vessels such as these can cost
tens of thousands of dollars, but gone unnoticed can cause catastrophic explosions when
hydrocarbon products are involved

www.flir.com
There was no visible evidence of this relief valve leaking.
However it is readily visible with thermal imaging.
You can see the relief valve on the right is properly sealed.

www.flir.com
Although this exchanger appears to be operating
hot its not. It is merely out of scale. The
cooling fins on the left side of the transformer
are plugged with carbon and debris

www.flir.com
Pump impellers on the suction side of this tank were being wiped out.
Heavy
erosion was also found on the pump case. An IR image shows why.
The sludge is piled almost to the 10” inlet line

www.flir.com
Tank Levels and Sludge
build up
Tank Levels
• Liquid level easily verified
*>43.2°C

40.0 *>106.7°F

105.0
100.0
35.0 95.0
90.0
85.0
80.0
30.0 75.0
70.0
65.0
60.0
*<27.0°C 55.0
50.0
45.0

Crude tank 40.0


35.0
30.0

*<28.1°F

Spheroid Tank

FSI
www.flir.com
This 10” piping system is completely plugged with debris.
Many times plugging begins where you have a notch in the
pipe. In this case the flange gasket faces. The
dark cool spot is due to a lack of flow in the piping system

www.flir.com
In this piping system a nitrogen truck was brought on site.
The nitrogen was put through a heater and hot nitrogen
was put in the line through via a 3/4 “ drain valve. As
the line heated a thermal wave was induced and build up
in the piping was easily detected.

www.flir.com
In the same manner steam can be used to create the same affect.
Nitrogen is used in many cases when steam or condensate can damage
internal liners s such as the ceramic or refractory liners used in many
power plants.
Steam or condensate can also accelerate corrosion when products
such as sulfur are present . This can create sulfuric acid and cause
corrosion problems

www.flir.com
Furnace and boiler tubes are an excellent application. However a common problem in
inspecting these tubes are measuring scale temperature. The ambient or background
temperature in your thermal imager should be elevated to the approximate emissivity
and temperature of the refractory or background. A tremendous amount of radiation
is reflecting and refracting throughout the furnace. Spot size and distance must be
considered. In the case of this image the cooler areas on the tubes should be where
measurements are taken. The spalling scale or slag on the tubes is scale or slag
temperature and is not an accurate way to measure the actual tube body.
Measurements should be taken on the darker (cooler) areas on the tubes for accuracy

www.flir.com
Out fall into cooling ponds
or reservoirs

www.flir.com
These images were taken from a helicopter flying from
200’ to 3000’. The dikes appear intact from the surface,
but water leaking to other areas can be a real and very
expensive environmental problem

www.flir.com
Use in Design of Heat
Pumps

www.flir.com
Gas Fired Power Plant overview. IR can be
used to look at emissions. Look at tank
liquid levels

www.flir.com
Coal Fired Power Plant overview
Look at and compare stack refractory and
boiler insulation efficiency

www.flir.com
Hot Spots on Furnace Duct

www.flir.com
Flare Monitoring

www.flir.com
Injection Molding

www.flir.com
Process flow in a Pressure
Vessel

www.flir.com
Igloo Ice Chests

www.flir.com
Looking Through Water
Vapor (Steam)

www.flir.com
Polymer Buildup In 30” Line

www.flir.com
Crude and Waste Oil Tan Levels

www.flir.com
Extruder Diagnostics

www.flir.com
Installing Foam Insulation
in a Jacketed Rail Car
Void Area

www.flir.com
Wire being extruded in a
steel mill

www.flir.com
Simulation of Rocket fuel leak
in Space

www.flir.com
Live, side by side jet engine comparisons

www.flir.com
Jet Engine Performance

www.flir.com
Tail Cone Thermal Image

www.flir.com
Jet Engine Diagnostics

www.flir.com
Jet Engine Diagnostics

www.flir.com
Expander Turbine Blades

www.flir.com
Jet Engines

www.flir.com
Jet Engine - Safety

www.flir.com
Possible broken stator bar

*>37.1°C

37.0

36.0

35.0

34.0

33.0

*<32.5°C

www.flir.com
Microprocessors

www.flir.com
Printed Circuit board

www.flir.com
Printed Circuit Boards

www.flir.com
Medical Applications are
Growing

www.flir.com
New Innovations
ThermoVision Ranger

Laser Rangefinder IR Imager

Color TV

Integrated Pan
and Tilt

FSI
www.flir.com
TM
ThermoVision now takes it
beyond that limit!

A new uncooled infrared camera from FSI


AUTOMATION specifically designed for continuous
monitoring of machines, products and processes

FSI
www.flir.com
ThermoVision

• 24/7 operation
• Specifically designed for continuous
Process applications
• Multi camera control
• Alarms and Triggers

FSI
www.flir.com
Ground Based Security
ThermoVision Sentry TM
Uncooled Imager
Provides Reliable 24/7
Operation

Integrated Pan/tilt
Simplifies Integration

Programmable Autoscan
Reduces workload
No Gears
FSI
www.flir.com
What a fire fighter sees when he
enters the building...

FSI
www.flir.com
What a fire fighter sees when he
enters the building... With IR

FSI
www.flir.com
The first IR Imager designed
specifically for fire fighting:

FSI
www.flir.com
“SCVA”™ Self Contained Viewing Apparatus
·Hands free
·Snaps-on to any brimmed helmet
·Light weight (1.5 Kg)
·No Cables

Front Clip

Back Strap Display


Imager

See through Mask


Battery

FSI
www.flir.com
Government Applications
Pentagon’s UAV Outrider Program

FSI
www.flir.com
Thank You

www.flir.com