Introduction to the Cabinet
1
Structure of DTMU
DTMU
MMI CBUS2
LMT MCU
OML
Clock
External Subrack number
synchronized clock and clock
MCK
2
Indicators on DTMU
3
Indicators on DTMU
DTMU
Indicat Color Description Status Meaning
RUN
or
ACT
LIU2 Green Indicates the Off E1 port 2 is normal when SWT is out
transmission status of E1 port 6 is normal when SWT is on PLL
E1 port 2 and port 6 On E1 port 2 near end alarm occurs when SWT is out LIU1
E1 port 6 near end alarm occurs when SWT is on LIU2
Fast flash (4 E1 port 2 remote end alarm occurs when SWT is out LIU3
Hz) E1 port 6 remote end alarm occurs when SWT is on
LIU4
LIU3 Green Indicates the Off E1 port 3 is normal when SWT is out
transmission status of E1 port 7 is normal when SWT is on SWT
E1 port 3 and port 7 On E1 port 3 near end alarm occurs when SWT is out ALM
E1 port 7 near end alarm occurs when SWT is on
Fast flash (4 E1 port 3 remote end alarm occurs when SWT is out
RST
Hz) E1 port 7 remote end alarm occurs when SWT is on
LIU4 Green Indicates the Off E1 port 4 is normal when SWT is out MMI
transmission status of E1 port 8 is normal when SWT is on
E1 port 4 and port 8 On E1 port 4 near end alarm occurs when SWT is out
E1 port 8 near end alarm occurs when SWT is on T2M
Fast flash (4 E1 port 4 remote end alarm occurs when SWT is out
Hz) E1 port 8 remote end alarm occurs when SWT is on FCLK
SWT Green Indicates handover Off LIU1 to LIU4 indicate the transmission status of E1 port
status of E1 1 to 4. T13M
On LIU1 to LIU4 indicate the transmission status of E1 port
5 to 8.
ALM Red Alarm indicators Off No hardware alarm
On Hardware alarm
4
Indicators on DTRU
DTRU
Indicator Color Description Status Meaning TX1
RUN Green Indicates the running On There is power supply or the board is faulty.
and power-on of the IN1
Off There is no power supply and the board is faulty.
DTRU
TCOM
Slow flash (0.25 Hz) The board is starting.
Slow flash (0.5 Hz) The board is running.
IN2
Fast flash (2.5 Hz) The DTMU is sending configuraiton parameters to
the DTRU.
TX2
ACT Green Indicates the TRX is On The board is running (the DTMU sends
working configuration parameters to the DTRU correctly
and the cell is starting). All the channels on the RST
two carriers can work normally. RUN
Off Communication between DTRU and DTMU is not ACT
set up ALM
Slow flash (0.5Hz) Only parts of the logic channels are working RF_IND
normally (including after TRX mutual aid).
RXM1
ALM Red Indicates alarm On (including high- Critical alarm occurs to the board.
frequency flash) RXD1
RXM2
Off The board is normal.
RXD2
RF_IND Red RF interface indicators On Standing wave alarm
Off Normal PWR
Slow flash (0.5 Hz) RL alarm
5
Ports on DTRU
Indicators on DTRU
DTRU
Interfac Type Description
TX1
e
IN1
TX1 N (male) TX1 output signals:
Output to the forepart of the RF when not in combiner TCOM
6
Indicators on DDPU
ANTB
Indicato Colo Description Status Meaning ANTA
r r DDPU
RUN Green Indicates the DDPU is On There is power supply and the board is faulty. RUN
running and powerd on ALM
Off There is no power supply or the board is
faulty. VSWRA
VSWRB
Slow flash (0.5 Hz) The board is running normally.
Fast flash (2.5 Hz) The DTMU is sending configuration
parameters to the DDPU or the DDPU is COM
loading software programs.
ALM Red Indicates an alarm On (including high- There is alarm(including standing wave alarm)
frequency flash) and the board is faulty. POWER
Off No fault
Slow flash (0.5 Hz) The board is starting or loading the newest
application programs RXA1
VSWRA Red Indicates a standing Slow flash (0.5 Hz) Standing wave alarm occurs to Channel A RXA2 TXA
wave alarm of Channel RXA3
On Standing wave critical alarm occurs to
A RXA4
Channel A
RXB1
Off No standing wave alarm occurs to Channel A
RXB2
VSWRB Red Indicates a standing Slow flash (0.5 Hz) Standing wave alarm occurs to Channel B RXB3 TXB
wave alarm of Channel RXB4
On Standing wave critical alarm occurs to
B
Channel B
Off No standing wave alarm occur to Channel B
7
Interface on DDPU
ANTB
ANTA
DDPU
Interface Type Description RUN
ALM
VSWRA
COM DB26 (female) Sends to the DDPU control signals, communication signals, clock signals and VSWRB
subrack number
POWER 3V3 Power supply input
TXA N (male) Input of the TX signals sent from the DTRU COM
Input of the DCOM combining signals
TXB N (male) Input of the TX signals sent from the DTRU
Input of the DCOM combining signals POWER
8
Typical configurationS2/2/2
(No combining mode)
DDPU
RXA2
TX A
RXA4
IN 1
IN2
RXM 1
diversity mode RXD 1
RXM 2
47.8)-1.0 DTRU
9
Typical configurationS2/2/2
(PBT mode)
DDPU
RXA1
RXA4
DDPU RXB3
RXB4
IN 1 IN 1
showed in the right slide TCOM TCOM
TX 2 TX 2
RXD 1 RXD 1
RXD 2 RXD 2
49
10
Typical configuration S4/4/4
( wideband transmit combining mode )
DDPU
RXA2
TX A
RXA4
RXB1
RXB3
TX B
DDPU RXB4
TX 1 TX 1
TCOM TCOM
wideband transmit combination IN2 IN2
RXD 1 RXD 1
(46 or 47.8)-3.3-1.0
RXM 2 RXM 2
RXD 2 RXD 2
DTRU DTRU
11
Typical Configuration S1/2/1
RXA3
TX A
RXA2
RXA3
TX A
RXA2
RXA3
TX A
RXB1
RXA4
RXB1
RXA4
RXB1
DDPU RXB2
RXB3
TX B
RXB2
RXB3
TX B
RXB2
RXB3
TX B
should be :
TX 1 TX 1
IN 1 IN 1
IN2 IN2
combining,receive TX 2 TX 2
independence mode;
RXM 1 RXM 1
DTRU2:transmit RXD 1 RXD 1
RXD 2
12
Installing Cables