Our Solutions …

GPS Glonass Beidou Galileo

Generate PTP/IEEE 1588 Wireless sync Frequency Other

Distribute IEEE-‐1588/PTP SyncE Wireless Sync

Refine

Harness

Precise time synchronization … we are the pulse in your


application

PAGE 2 © 2016 QULSAR, INC. All Rights Reserved.


The Company

◀ HQ: San Jose + R&D office in Stockholm (Sweden)


◀ Worldwide sales team in major countries [US, Europe, China,
India, S. Korea & Japan]
◀ Established world wide experts in precision timing solutions
• Precision timing technologies
• Time synchronization systems and subsystems
• Testing in real-‐world carrier networks
◀ Field-‐proven technology and solutions
• Large deployment in China Mobile
• Small cell deployment in Japan
• Integration with SOCs: TI and Cavium
• In Carrier Ethernet platforms for mobile backhaul

PAGE 3 © 2016 QULSAR, INC. All Rights Reserved.


Team Strengths & Differentiation

◀ Member & contributor to emerging standards


• Represented in ITU-‐T (G.826x & G.827x evolution)
• Packet timing & networking IEEE groups
◀ Extensive expertise in testing & validation
• Actual performance testing (pre & post turn up)
• Trial support & trouble shooting
◀ Intellectual property & 7+ patents
◀ Performance optimization + system design
experience & expertise
PAGE 4 © 2016 QULSAR, INC. All Rights Reserved.
Standard Requirements
ITU / 3GPP sync requirements:

Today 2016+

Standard GSM CDMA LTE-‐FDD LTE-‐TDD


5G
Precision 50 X 10-‐9 freq 3-‐10 µs 50 X 10-‐9 freq 1.5 µs
Backhaul 16 X 10-‐9 freq N/A (GPS) 16 X 10-‐9 freq 1.1 µs

Future upgrades Overlay LTE-‐Adv services


demand MBMS / eICIC / COMP-‐A 5 µs -‐0.5 µs

MBMS  Multimedia Broadcast Multicast Services


eICIC 
 enhanced Inter-‐Cell Interference Coordination
CoMP-‐A Coordinated Multi-‐Point, Advanced

PAGE 5 © 2016 QULSAR, INC. All Rights Reserved.


ITU-‐T Recommendations
G.826X –Frequency G.827X –Time & Phase
Agreed Consented Ongoing
Definitions G.8260
Definition & Metrics

G.8261 G.8271
Basics Sync in packet Networks - Time & Phase in packet Networks
Frequency

incl. in G.8261 G.8271.1


Jitter/Wander – SyncE Network PDV – Time/Phase
Network
Requirements
G.8261.1 G.8271.2 (Future)
Network PDV – Frequency Network limits partial support

G.8273.2 T-BC/TSC
G.8262 G.8272
SyncE (EEC) PRTC G.8273.3 T-TC
Clock
G.8273 G.8273.4 APTSC
G.8263
Slave Clock (PEC) Network Clocks

G.8264
SyncE (ESMC)
Methods G.8275
Architecture Time/Phase
G.8265
Architecture Frequency

G.8275.1
PTP Profile 1 – Time/Phase
G.8265.1 Eth Multicast
PTP Profile 1 – Frequency Full on timing support
IP unicast
Profiles No on timing support
G.8275.2
PTP Profile 2 – Time/Phase IP
unicast -Partial timing support

PAGE 6 © 2016 QULSAR, INC. All Rights Reserved.


Network Topology of IDEA POC

8 NE GGOOKKUULLAAMM 10 NE MMEETA
TAGGUULILI
BANGALORE EoSDH REOGUMTER EoSDH IDU-‐E1G0M
00
PTP GM ECI (ALU) ECI (NEC)

ONE MW
APOLO HOSP. VIJAYA_CLE
5 NE NEC 400
IDU-‐400 (NEC IDU-‐400 EoSDH
1MW) (NEC) ECI
METAGULI_TVS
IDU-‐400 (NEC)

MARUTINAGAR ONE MW BRINDAVAN_EXT ONE MW


IDU-‐200 (NEC) NEC 200 IDU-‐400(NEC) NEC 400

PAGE 7 © 2016 QULSAR, INC. All Rights Reserved.


Explained Terms

Term Explanation Causes & Effects


Asymmetry Difference between forward and reverse Uncorrectable without an
independent sync source
paths (usually NOT same)
Sync PTD One-‐way delay (latency) for PTP stream Greater delay  greater
asymmetry  greater time
sync error

Sync PDV Packet delay variation Larger PDV  larger packet


sync error; algorithms used to
improve performance in the face
of PDV

PAGE 8 © 2016 QULSAR, INC. All Rights Reserved.


Test Results Summary

S/No. CATEGORY TEST ID No. OF NE/HOPES FREQ.OFFSET SYNC PDV SYNC PTD (LATENCY) ASYMMETRY
(SHORT
DURATION)

1 BANGALORE GOKULAM 1a 8 EoSDH 2ppb 9.905 us 12.214 ms 5.623 us


2 METAGULI 2a 18 EoSDH 14 ppb 21.250 us 7.260 ms 39.001 us
3 METAGULI_TVS 6a 19 (18EoSDH+1MW) 32 ppb 22.192 us 5.782 ms 39.595 us
4 APOLO HOSPITAL 13a 14 (13EoSDH+1MW) 122 ppb 19.565 us 12.804 ms 34.468 us
5 GOKULAM IP RAN ROUTER METAGULI 3a 10 EoSDH 14ppb 9.257 us 0.150 ms 25.943 us
6 MARUTINAGAR 4a 13 (10 EoSDH+3MW) 60ppb 17.373 us 6.149 ms 18.388 us
7 METAGULI_TVS 7a 11 (10 EoSDH+1MW) 14ppb 12.178 us 0.428 ms 28.531 us
8 BRINDAVAN_EXT 9a 12 (10 EoSDH+2MW) 21ppb 12.973 us .576 ms 18.23 us
9 VIJAYA CIRCLE 11a 5 EoSDH 65ppb 15.853 us NA NA
10 APOLO HOSPITAL 14a 6 (5EoSDH+1MW) 102ppb 17.682 us 0.617 ms 25.947 us
11 METAGULI FBER POP MARUTINAGAR 5a 3MW 53ppb 15.259 us 0.802 ms 16.386 us
12 METAGULI_TVS 8a 1MW 1ppb 7.683 us 0.285 ms -‐0.384 us
13 BRINDAVAN_EXT 10a 2MW 5ppb 8.556 us 0.432 ms -‐10.442 us
14 TILAKNAGAR FIBER POP NR_MOHALLA 12a 4MW 12ppb 40.632 us 0.756 ms 29.871 us

PAGE 9 © 2016 QULSAR, INC. All Rights Reserved.


Results [with GM @ Bangalore]
FREQ.OFFSET in ppb SYNC PDV in μs
40 25
32 20 21.25 22.192
30
20 15
14 10 9.905
10 5
0 2
0
GOKULAM METAGULI METAGULI_TVS GOKULAM METAGULI METAGULI_TVS

BANGALORE BANGALORE

8 hops 8 hops 18 hops 18 hops + 1mw


18 hops 18 hops + 1mw

ASYMMETRY in μs SYNC PTD in ms


60 15
12.214
40 39.001 39.595 10
7.26 5.782
20 5
5.623 0
0
GOKULAM METAGULI METAGULI_TVS GOKULAM METAGULI METAGULI_TVS

BANGALORE BANGALORE

PAGE 10 © 2016 QULSAR, INC. All Rights Reserved.


Test Topology: Gokulam EGM

8 NE GOKULAM 10 NE METAGULI
BANGALORE EoSDH GOKULAM
ROUTER EoSDH IDU-‐1000
PTP GM ECI EGM
(ALU) ECI (NEC)

ONE MW
APOLO HOSP. VIJAYA_CLE
5 NE NEC 400
IDU-‐400 (NEC IDU-‐400 EoSDH
1MW) (NEC) ECI
METAGULI_TVS
IDU-‐400 (NEC)

MARUTINAGAR ONE MW BRINDAVAN_EXT ONE MW


IDU-‐200 (NEC) NEC 200 IDU-‐400(NEC) NEC 400

PAGE 11 © 2016 QULSAR, INC. All Rights Reserved.


Results [with EGM @ Gokulam]
FRE. OFFSET in ppb SYNC PDV in us
80
20
60 60 17.373
15
40 12.178 12.973
10 9.257
20
14 14 21
5
0
METAGULI 0
METAGULI_TVS BRINDAVAN_EXT MARUTINAGAR METAGULI METAGULI_TVS BRINDAVAN_EXT MARUTINAGAR
GOKULAM RAN ROUTER GOKULAM IP RAN ROUTER

10 hops 10 hops + 10 hops + 10 hops + 10 hops + 10 hops + 10 hops +


10 hops
1mw 2 mw 3 mw 1mw 2 mw 3 mw

ASYMMETRY in us SYNC PTD in ms


7
30
28.531 6 6.149
25 25.943
5
20
18.23 18.388 4
15 3
10 2
5 1
0.15 0.428 0.576
0 0
METAGULI MARUTINAGAR METAGULI METAGULI_TVS BRINDAVAN_EXT MARUTINAGAR
METAGULI_TVS BRINDAVAN_EXT
GOKULAM IP RAN ROUTER GOKULAM IP RAN ROUTER

PAGE 12 © 2016 QULSAR, INC. All Rights Reserved.


Test Topology: Metaguli EGM

8 NE GOKULAM 10 NE METAGULI
BANGALORE EoSDH GOKULAM METAGULI
ROUTER EoSDH IDU-‐1000
PTP GM ECI EGM EGM
(ALU) ECI (NEC)

ONE MW
APOLO HOSP. VIJAYA_CLE
5 NE NEC 400
IDU-‐400 (NEC IDU-‐400 EoSDH
1MW) (NEC) ECI
METAGULI_TVS
IDU-‐400 (NEC)

MARUTINAGAR ONE MW BRINDAVAN_EXT ONE MW


IDU-‐200 (NEC) NEC 200 IDU-‐400(NEC) NEC 400

PAGE 13 © 2016 QULSAR, INC. All Rights Reserved.


Results [with EGM @ Metaguli]
FREQ.OFFSET in ppb SYNC PDV in us
60 20
53
15 15.259
40
10 8.556
20 7.683
5
0 1 5 0
METAGULI_TVS BRINDAVAN_EXT MARUTINAGAR METAGULI_TVS BRINDAVAN_EXT MARUTINAGAR
METAGULI FBER POP METAGULI FBER POP

1mw link 2mw links 3mw links 1mw link 2mw links 3mw links

ASYMMETRY in us SYNC PTD in ms


20 1
15 16.386 0.8 0.802
0.6
10 10.442
0.4 0.432
5 0.2 0.285
0 0.384 0
METAGULI_TVS BRINDAVAN_EXT MARUTINAGAR METAGULI_TVS BRINDAVAN_EXT MARUTINAGAR
METAGULI FBER POP METAGULI FBER POP
PAGE 14 © 2016 QULSAR, INC. All Rights Reserved.
TEST RESULTS ANALYSIS
Different sites with GM & EGM

PAGE 15 © 2016 QULSAR, INC. All Rights Reserved.


METAGULI_TVS

FRE. OFFSET in ppb SYNC PDV in us


40 25
22.192
32 20
30 15
20 10
12.178
14 7.683
10 5
0 1 0
BANGALORE GOKULAM METAGULI BANGALORE GOKULAM METAGULI EGM
GM 19NE EGM 11NE EGM 1NE GM 19NE EGM 11NE 1NE
METAGULI_TVS METAGULI_TVS

ASYMMETRY in us SYNC PTD in ms


50 8
40 39.595 6 5.782
30 28.531 4
20
10 2
0 0.384 0 0.428 0.285
BANGALORE GOKULAM METAGULI EGM BANGALORE GOKULAM METAGULI EGM
GM 19NE EGM 11NE 1NE GM 19NE EGM 11NE 1NE
METAGULI_TVS METAGULI_TVS

PAGE 16 © 2016 QULSAR, INC. All Rights Reserved.


BRINDVAN_EXT
FRE.OFFSET in ppb SYNC PDV in us
30 15
12.973
20 21 10 8.556
10 5
5
0 0
GOKULAM EGM METAGULI EGM GOKULAM EGM METAGULI EGM
BRINDAVAN_EXT BRINDAVAN_EXT

ASSYMETRY in us SYNC PTD in ms


20 18.23
15
1
10 10.442 0.576
5
0.5 0.432
0
0
GOKULAM EGM METAGULI EGM GOKULAM EGM METAGULI EGM
BRINDAVAN_EXT BRINDAVAN_EXT

PAGE 17 © 2016 QULSAR, INC. All Rights Reserved.


MARUTINAGAR
FREQ. OFFSET in ppb SYNC. PDV in us
65 18
17 17.373
60 60 16
55 53 15 15.259
50 14
45 GOKULAM EGM METAGULI EGM
GOKULAM EGM METAGULI EGM
MARUTINAGAR
MARUTINAGAR

ASYMMETRY in us SYNC PTD in ms


19 8
18 18.388 6 6.149
17 4
16 16.386
2
15 0.802
0
GOKULAM EGM METAGULI EGM GOKULAM EGM METAGULI EGM

MARUTINAGAR MARUTINAGAR

PAGE 18 © 2016 QULSAR, INC. All Rights Reserved.


Results Analysis : Sites Vs. GM/EGM
MEASUEREMENT LOCATION GM/EGM LOCATION No. OF FREQ.OFFSET (SHORT SYNC PDV SYNC PTD ASYMMETRY
NE/HOPS DURATION) (LATENCY)

METAGULI_TVS BANGALOREGM 19 32 ppb 22.192 us 5.782 ms 39.595 us

GOKULAM EGM 11 14ppb 12.178 us 0.428 ms 28.531 us

METAGULI EGM 1 1ppb 7.683 us 0.285 ms 0.384 us

BRINDAVAN_EXT GOKULAM EGM 12 21ppb 12.973 us 0.576 ms 18.23 us

METAGULI EGM 2 5ppb 8.556us 0.432 ms 10.442 us

MARUTINAGAR GOKULAM EGM 13 60ppb 17.373 us 6.149 ms 18.388 us

METAGULI EGM 3 53ppb 15.259 us 0.802 ms 16.386 us

PAGE 19 © 2016 QULSAR, INC. All Rights Reserved.


IMPACTS:
SITE BANGALORE GM GOKULAM EGM IMPROVEMENT METAGULI EGM IMPROVEMENT

FREQUENCY OFFSET:

METAGULI_TVS 32ppb 14ppb 18ppb 13ppb


1ppb

SYNC PDV:

10.01us 4.5us
METAGULI_TVS 22.19us 12.18us 7.68us

SYNC PTD:

METAGULI_TVS 5.78ms 0.43ms 5.35ms 0.15ms


0.28ms

ASYMMETRY:

METAGULI_TVS 39.59us 28.53us 11.06us 0.38us 28.15us

PAGE 20 © 2016 QULSAR, INC. All Rights Reserved.


IMPACTS:
SITE GOKULAM EGM METAGULI EGM IMPROVEMENT

FREQUENCY OFFSET:

BRINDAVAN_EXT 21ppb 5ppb 16ppb


MARUTINAGAR 60ppb 53ppb 7ppb

SYNC PDV:

BRINDAVAN_EXT 12.97us 8.56us 4.41us


MARUTINAGAR 17.37us 15.26us 2.11us

SYNC PTD:

BRINDAVAN_EXT 0.58ms 0.43ms 0.15ms


MARUTINAGAR 6.15ms 0.80ms 5.35ms

ASYMMETRY:
BRINDAVAN_EXT 18.23us 10.44us 7.79us
MARUTINAGAR 18.39us 16.38us 2.01us

PAGE 21 © 2016 QULSAR, INC. All Rights Reserved.


Result Analysis

Backbone ring performance


 acceptable
Large degradations observed
Freq sync delivery is acceptable in aggregation & access ring

Large number of hops +


eNode B Grand Master variable network & traffic +
GM deep in the n/w leads to resiliency & mw links  critical impact
performance issues:
GPS failure = severe sync impact [ex: failure
during Apollo site PoC]
PDV & asymmetry with too many hops – cannot
be handled even by improved algorithms
Micro-wave links contributes significantly to
degradation

Network not yet ready for phase delivery


(needed for LTE-A services)
PAGE 22 © 2016 QULSAR, INC. All Rights Reserved.
Result Analysis [contd.]

eNode B Place edge GM


Edge Master Grand Master
Slave with PDV & asymmetry impacts
sophisticated improved significantly after
algorithm  can
placing Edge GM
further improve
performance

PAGE 23 © 2016 QULSAR, INC. All Rights Reserved.


General Recommendations
◀ Microwave links have variable behavior based on environmental
effects such as weather
◀ Particularly problematic when there is no “wayside” channel which is low-
speed but fixed
◀ Microwave links should have BC / TC enabled (if supported)
◀ Careful with G.8263 suggestion of 150us floor variation – suitable
ONLY for frequency and requires ST3E+ oscillator
◀ Rule of thumb: Using a TCXO, the floor variation (i.e. PDV) can usually
be attenuated by a factor of 10
◀ PTP cannot correct for asymmetry…. Any asymmetry eats into the
1.1us allowance
◀ Wherever feasible use an APTSC (Assisted Partial Timing Support
Clock) solution
◀ Minimize number of PTP-unaware (no TC/BC) between Master and
Slave Clocks… keep source as close as possible to sink

PAGE 24 © 2016 QULSAR, INC. All Rights Reserved.


Recommendations
◀ Network re-engineering to compensate large PDV &
asymmetry
◀ Microwave links should have BC / TC enabled
◀ PTP Edge GMs at the access network [ex: nodes like
Metaguli]

Expected Benefits:
◀ Lower PDV & asymmetry in n/w improve PTP sync to
eNodeB
◀ GPS failure impact minimized
◀ Make IDEA network “future ready” for Phase sync
delivery (1.1μs) for LTE-A services
PAGE 25 © 2016 QULSAR, INC. All Rights Reserved.
QULSAR SOLUTION
Qg2 & sync end to end solution

PAGE 26 © 2016 QULSAR, INC. All Rights Reserved.


Differentiation

Pico cell

1.5 us over 10-


hops in G.8261
test

Micro cell

Grand Master

Industry leading algorithms


mitigating network
disturbances & extracting
Macro cell accurate time
Multi-clock algorithms
optimizing performance
Innovative algorithms work
with low priced oscillators
PAGE 27 © 2016 QULSAR, INC. All Rights Reserved.
Edge Sync

Pico cell

Higher accuracy &


greater resiliency

Micro cell

Edge Master Grand Master

Low cost of ownership end to


end solution

Macro cell Optimized for ‘cluster sync’


deployment

Innovative end-to-end self-


healing sync network feature

PAGE 28 © 2016 QULSAR, INC. All Rights Reserved.


Cluster Sync

Pico cell “cluster”


Higher accuracy &
greater resiliency
Micro cell

Edge Master Grand Master

Low cost of ownership end to


end solution

Macro cell Optimized for ‘cluster sync’


deployment

Innovative end-to-end self-


healing sync network feature

PAGE 29 © 2016 QULSAR, INC. All Rights Reserved.


Managed Timing Engine Portfolio

Module:
M series

Board: Local Gateway Master


P series (system)
Qg 2

Technology &
Design
licensing

PAGE 30 © 2016 QULSAR, INC. All Rights Reserved.


Innovative Features
Optimized for deployment at the network edge

ToD
GNSS Frequency
PTP PTP
SyncE
SyncE
Position / location

Self organizing resilient


Qulsar
sync network
slave
Multiple holdover options
Scalable (slave handling)
Self healing robust sync* * Only with Qulsar
Management slaves
Metrics
PAGE 31 © 2016 QULSAR, INC. All Rights Reserved.
Technical Details
Features Benefits
Built in GNSS receiver with multiple
holdover options Small form factor, simpledesign

Full IEEE 1588 – 2008 Grandmaster Low cost of operation

Supports G.8265.1/.2 frequency Unique management to dramatically


standard & G.8275.1 time & phase reduce complexity
standard
Scalable and flexible deployments
Supports IEEE PC37.238 Power
profile

Applications
Supports 1-‐step & 2-‐step clock
Hetnets & Small cell clusters

LED indicator status Backhaul synchronization

Remote provisioning & Smart grid networks


management with CLI & SNMP

Industrial internet of things


Future: XML / web interface

PAGE 32 © 2016 QULSAR, INC. All Rights Reserved.


Datasheet Excerpt – Qg2
Product Images PTP Master • Accuracy with GNSSas reference, better than
±25ns
• Unicast capacityscalable: 32 / 64 / 128 slaves
(optional)

Holdover • 2hrs 1.5us/16ppb 24 hrs


(customizable) • 4hrs 1.5us/16ppb 24 hrs
• 8hrs 1.5us/16ppb 24 hrs
Other Software • DHCP client
Features • FTP/TFTP server
• TELNET server
• SSH server
Input • 1x GNSS L1 Antenna (SMA) • Serial terminal
• PTP (in Gateway mode) • Remote firmware upgrade
• Synchronous Ethernet • Command line interface configuration (Telnet,
• 1x IEEE1588 (RJ45) on10/100/1000BaseT SSH or serial port terminal)
Output
• Synchronous Ethernet Management • RemoteCLI & SNMP via Ethernet
• Local console
Other • 1 PPS out (BNC) up to2 kHz with 1 µs resolution
Interfaces • 1x syntonized frequency(BNC), configurable as 5, Diagnostics • LED indicator -‐Power status, GPS Acquisition,
10, 20 or 25 MHz. Ethernet Port link activity
• 1x ToD out (RJ45), 4800/9600 baud onRS232D
with configurable format • Supply: 5V+/-‐10%
• 1x Console(RJ45)
Operating
Specifications
Profiles • ITU-‐T G.8265.1 frequency delivery profile
• ITU-‐T G.8275.1 time/phasedelivery profile (Full Operating • 0o C to 70oC
Timing Support) temperature
Size • 120 mm x 103 mm x 30 mm

PAGE 33 © 2016 QULSAR, INC. All Rights Reserved.


Motivation

Small cells

GNSS
PTP / 1588 Qg 2 Grand Master

Qg 2
Micro cell Qg2:
 Small form factor, highly scalable GM +
GNSS Qg 2
Gateway clock
 Can be deployed quickly & universally
Macro cell
 Uses multiple inputs to provide robust sync
 Supplements GNSS sync to enable robust
‘assisted holdover’ without expensive
OCXOs
PAGE 34 © 2016 QULSAR, INC. All Rights Reserved.
“Cluster” Sync
0.3-0.5 μs inter-
cell sync
+ special syncE ‘aware’
oscillator (optional)

Pico cell “cluster”


 Minimize hops
 Use syncE aware switches / routers
Micro cell  Use T-BC switches (full on-path
support)

Qg 2

Macro cell
Precise synchronization over Ethernet backhaul
for small cells / C-RAN deployments

PAGE 35 © 2016 QULSAR, INC. All Rights Reserved.


Self-‐Healing Sync Network
Uses: Unique Qulsar patented end-to-
end technology

Pico cell “cluster”

Micro cell
X  Enables robust, accurate cluster sync
 Leverages deployed GNSS installations
Qg 2  Very effective for larger clusters

 When primary GNSS input to EGM fails


Macro cell  Selects a QLSR slave with GNSS (changes that
Ordinary clock to master mode)
 Uses GNSS input to stabilize entire cluster
 Only possible with QLSR embedded slave technology
PAGE 36 © 2016 QULSAR, INC. All Rights Reserved.
C-‐RAN

◀ Separation of eNodeB into Base band unit


(BBU) & Remote radio-‐head (RRH)
◀ Demand extremely precise sync (100 ns = 0.1
μs)
◀ Design inexpensive system with TCXO at RRH &
any switched node
◀ Goal: 0.1 μs phase & <1 ppb between BBU &
RRH

PAGE 37 © 2016 QULSAR, INC. All Rights Reserved.


C-‐RAN Sync Solution 1
High precision QLSR slaves

0.1 μs intra-BBC
-RRH sync RRHs SyncE locked TCXO

Gateway clocks / co-‐


located EGMs


BBU Edge Gateway
Expanded logical
picture:
BBCs

Slave
RSRla
Hve
RRHs
RRH …
(slaves) Backhaul (GM)
= Switch

BBU © 2016 QULSAR, INC. All Rights Reserved.


PAGE 38
C-‐RAN Sync Solution 2
High precision QLSR slaves

0.1 μs intra-BBC
-RRH sync RRHs T-‐BCs

Gateway clocks / co-‐


located EGMs


BBU Edge Gateway
Expanded logical
picture:
BBCs

Slave
RSRla
Hve
RRHs
RRH …
(slaves) Backhaul (GM)
= Switch

BBU © 2016 QULSAR, INC. All Rights Reserved.


PAGE 39
Sync for C-‐RAN

◀ Boundary clock in every BBU-‐card (BBC) or co-‐locate EGM


◀ BBU has holdover capability (and maybe linked to GM / EGM)
◀ Recommend high performance QLSR module in BBUs
◀ Use high performance slave with TCXO in RRHs
◀ BBU to RRH link switches must support syncE & over GbE
◀ Use special disciplined TCXOs at link switches / routers
◀ Low cost of small-‐cell solution + lower cost of total solution

PAGE 40 © 2016 QULSAR, INC. All Rights Reserved.


Monitoring System
Sync Fractional
Embedded Sync Monitoring: Topology Frequency Offset
Each embedded clock reports its
metrics to the host system

MTIE TIE

Pico cell “cluster”

Operator sync
deduction & Network Management &
decision engine NMS / OSS “plug in”
Macro cell Local Sync Monitoring:
PTP metrics reported from slave
(Time error, floor etc.)
Self healing / alternative master Full network sync Monitoring:
status Sync network topology GNSS
GNSS signals from slaves monitored signal monitoring / problem
Asymmetry monitoring reports
Local oscillator performance GNSS jamming detection
monitoring PTP performance monitoring
In-building cluster Local area performance reports
PAGE 41 © 2016 QULSAR, INC. All Rights Reserved.
GNSS Tether

Qulsar wireless tether can


distribute GNSS sync to Qg
2

Qg 2 has to be
deployed where
GNSS does not
penetrate

Uses patented Qulsar wireless sync technology for


“tethering”

PAGE 42 © 2016 QULSAR, INC. All Rights Reserved.


Small cell cluster (ex 1)

IEEE 1588 PTP

Pico-cell cluster,
Pico Cells
uses GNSS
wherever visible
any cell can be
GM

Ethernet
Backhaul EPC
Access Device
Fiber
PTP Slave Clock

PTP Boundary Clock

Local Gateway Master


PAGE 43 © 2016 QULSAR, INC. All Rights Reserved.
Small cell cluster (ex 2)

IEEE 1588 PTP

Pico Cells

Qg 2

Ethernet
Backhaul EPC
Access Device
Fiber
PTP Slave Clock

PTP Boundary Clock

Local Gateway Master


PAGE 44 © 2016 QULSAR, INC. All Rights Reserved.
Network edge & backhaul

Macro Cell
IEEE 1588 PTP
Qg 2

CE Demarcation Device
Backhaul EPC

PTP Slave Clock

Micro Cells PTP Boundary Clock


Pico Cells
Local Gateway Master

PAGE 45 © 2016 QULSAR, INC. All Rights Reserved.


Macro Cluster

Macro Cell

IEEE 1588 PTP

Qg 2
Pico Cells
Micro Cells
LTE Fiber Backhaul EPC
Gateway/
Demarcatio
PTP Slave Clock
n Device
PTP Boundary Clock

PTP Local Gateway


Master
PAGE 46 © 2016 QULSAR, INC. All Rights Reserved.
Roadmap

Qg4
Qg2

EGM
• 32/64 /128 slaves • Multi-sync inputs
• Multiple h/o options • Wireless Sync
• GNSS (GPS & Beidou) + PTP • Performance Metrics
• 8-10 slaves enhancements
• Multiple h/o options + SyncE
• Output PTP/SyncE • Positioning server
• Input GPS only • Enhanced indoor coverage and
• Output PTP/SyncE • Optical GE (optional)
• SNMP + CLI Mgmnt. positioning (Alternative satellite
• No management interface inputs)
• POE • POE
• Sync Performance Metrics
• VLAN tagging

Q4 2015 Q1 2016 Q3 2016

PAGE 47 © 2016 QULSAR, INC. All Rights Reserved.


Conclusion

◀ A completetime synchronization solution


• Customer can focus on core technology
• Support for trials & testing with end customer
◀ Market ready solution
• Rapid time to market
• Flexible solution – adaptable for multiple applications
◀ Expertise & technology
• Industry expertise with own developed core technologies
• Standards awareness, compliance and continuous support

PAGE 48 © 2016 QULSAR, INC. All Rights Reserved.


PAGE 49 © 2016 QULSAR, INC. All Rights Reserved.