Operational Training

CLIENT:
LOCATION:

1
Product Training

Power UPS

2
An Appeal and Request :
 Actively Participate, it benefits all
 Ask Questions as they arise in your mind
 Make contributions
 All the above activities add value to this Training
program
 Switch-off Hand Phones or keep them on silent
mode.
 Start relaxed and you will leave refreshed

3
FEATURES
High reliability IGBT inverter
Available with 6 or 12 pulse rectifier
Paralleling of up to six units using either
modular or centralized static bypass switch
High efficiency Eco-Mode
Advanced battery management
Back feed protection
Battery ground fault warning
Available in LBS topology for “High
availability ” applications
Frequency converter 50/60 Hz with or without battery
SNMP network compatible with dynamic
monitoring
BMS connectivity through either
Modbus, JBus or PROFIBUS
Optional monitoring through Netcom Card
by using LAN Network or Internet.
Many other optional features to suit your power needs
Rating available 80,120,160,200,300,400,600,800 KVA
UPS Block Diagram – Single Module
Parallel Redundant (1+1) UPS System

Mains STATIC
RECTIFIER INVERTER
Supply SWITCH

1+1 PARALLEL C ONTROL

Control Logic

UPS
BATTERY Output
Supply
Common Batt. Panel

1+1 PARALLEL C ONTROL

Mains STATIC
RECTIFIER INVERTER
Supply SWITCH
Dual Bus Distribution Scheme
Brief About Current Set Up:
 UPS Ratings:
 Quantity:
 Configuration:
 Battery Make:
 Battery Type:
 Battery Qty( No. of Strings):
 PDU Ratings:
 Quantity:
RECTIFIER CONTROL SYSTEM
I/p Fuses
Q1
INPUT
I/ P TO
MAINS RECTIFIER
CHOKE INVERTER
SUPPLY

DC VOLTAGE
FEEDBACK
CURRENT
INPUT C.T.

BATT.
REC
DRV

RLB BATTERY
BREAKER
BOX

OLB MIMIC

ULB PLB

AS400 ON GENERATOR

HVI
INVERTER CONTROL SYSTEM

D.C. BUS
O/P TO
INVERTER TXR & STATIC
CAP. SWITCH

IGBT

OUTPUT VOLTAGE
INVERTER DCCT
DRV

INVERTER
LOGIC BOARD

MIMIC OLB

PLB ULB

INVERTER OFF AS400

HVI
STATIC SW CONTROL SYSTEM
Q3

Q2 BYPASS FUSES
BYPASS
SUPPLY

Q4
O/P OUTPUT
STATIC SUPPLY
INVERTER TXR
SWITCH
CAP

INVERTER VOLTAGE

OUTPUT VOLTAGE
BYPASS VOLTAGE

ST.SW.

OUTPUT CT
DRV.
BYPASS CT

MIMIC

ULB OLB

HVI
POWER CIRCUIT MANTENANCE
BYPASS
Q3

Q2
BYPASS VOLTAGE BYPASS CT
BYPASS EMC
SUPPLY FILTER OUTPUT
SUPPLY
BYPASS FUSES
I/P FUSES Q4
Q1
INPUT EMC
EMC O/P STATIC FILTER
MAINS I/P RECT. INVERTER
FILTER CHOKE Txmer SWITCH
SUPPLY

HARMONIC DCCT
REC IGBT ST/ SW
FILTER ASSY DRV DRV DRV
DC
F/B. INVERTER INVERTER
INPUT INPUT OUTPUT OUTPUT
VOLTAGE C.T. DCCT F/B VOLTAGE CT
Battery
RLB ILB
Breaker
Box

OLB MIMIC

HVI ULB PLB

AS400

OPTIONAL ITEMS
PCBs

 Rectifier logic board


 Inverter logic board
 UPS logic board
 Parallel logic board
 Parallel connection board

 AS400 board 1

X3

HVI board
Q1 Q2 Q4


12

X4
12

Q3

-
U1 V1 W1 U3 V3 W3 N3 N2 U2 V2 W2
PCBs (contd.)

 Operator Control MIMIC


 Operator logic board
 DC-DC board
 AC-DC board
 Rectifier Driver Board
 Static switch driver board X3
1

Q1 Q2 Q4
12

IGBT driver PCB


X4


12

Q3

-
U1 V1 W1 U3 V3 W3 N3 N2 U2 V2 W2
Parallel Connections
UPS MODULE -1 UPS MODULE -2 UPS MODULE -3

TO PARALLEL TO PARALLEL TO PARALLEL


LOGIC BOARD LOGIC BOARD LOGIC BOARD

PARALLEL
PARALLEL PARALLEL
PARALLEL PARALLEL
CONNECTOR PCB CONNECTOR PCB CONNECTOR PCB
CONNECTOR PCB CONNECTOR PCB
X1 X1
X1

X2 X2
X2

34 pin flat screen cable

PARALLEL LOGIC BOARD FUNCTIONS :


1) General module output control
2) Module frequency control & Synchronization control
3) Output current control
4) Common battery control
Remote Alarm Board - AS400
LED’S ON MIMIC - Hipulse

Inverter OK Load Bypass LCD Screen Load Bar Graph


% of load

NORMAL
OPERATION
Bypass OK
Rectifier OK
ESC MENU ENTER
Battery CB open

Inverter switched OFF Battery Bar Graph


through this switch Load inv Hooter Cancel % of Battery charge
UPS PARAMETER

MENU
 MEASUREMENT
 FUNCTION
 MAINTENANCE
 SETUP
UPS PARAMETER –SETUP
UPS PARAMETER –MAINTENANCE

MAINTENANCE

FACTORY SETTING
PASSWORD (PASSWORD) 00000000
S . N. (SERIAL NUMBER) XXXXXXX
12.00.00 (CURRENTTIME & DATE) 12.01.00 01.01.00
LAST SER (LAST SERVICE TIME AND DATE) 01.01.96
NEXT SER. (NEXT SERVICE TIME AND DATE) 01.01.96
UPS PARAMETER - FUNCTION
UPS PARAMETER - FUNCTION
(contd.)
UPS PARAMETER –MEASUREMENT
Switch Position
UPS Switch – ON
Should be in OFF condition
Q3

Bypass Q2 2
3
Mains Q1 ~ - Q4 Output
- ~
1 CBB
4
UPS Switch – OFF
Should be in OFF condition
Q3

Q2 3
Bypass

Q4
Mains Q1 ~ - Output

5
- ~
CBB 2
1

press“inv off” from


mimic
Transfer from inverter mode to
maintenance mode
2
Q3

Q2 5
Bypass

Q4
Mains Q1 ~ - Output

4
- ~
CBB 3
1

press“inv off” from


mimic
Transfer from maintenance mode to
inverter mode
3
Q3

Bypass Q2

1 2
Mains Q1 ~ - Q4 Output
- ~
4 CBB
5
6
press“Inv On”
from mimic
THANK YOU…………………………
Remote Alarm Board - AS400
X3
Load on Bypass
R Low Battery
E
L Maintenance Bypass open
A
Y Mains or Rectifier Failure

Common (0V)
X1
X3
UPS BYPASS

R BATTERY LOW
E
L UPS ON
A
Y UTILITY FAILURE(RECTIFIER MAINS)

COMMON (0V)

X4 UPS BYPASS

BATTERY LOW
R
E UPS ON
L
A UTILITY FAILURE (RECTIFIER MAINS)
Y
COMMON (0V)