Académique Documents
Professionnel Documents
Culture Documents
17
365 DAYS AIR CONDITIONING
-10C -15C
10C deg.
-15C
Current model New model
Line up
* NA for India Market in 2006 18K 24K 36K 48K
Reverse-arc shape
New development for high pressure, low sound fan
wing assists in
→The bat wing fan realized the sound level reducing pressure
equivalent to current model. losses
INSTALLATION FLEXIBILITY
Light weight
wind
- Easy carrying-in on installation site
Weekly Timer ○ ○ ○ ○ -
Remote sensor ○ ○ ○ ○ -
Wireless Remote
○ - - - -
controller kit (4-way)
Wireless Remote
- - ○ - -
controller kit (Ceiling)
Wireless Remote
- ○ - ○ -
controller kit
1:1 model connection
○ ○ ○ - -
interface ( SMMS * )
Wireless Remote
- - - ○ ○
controller
Practical Case Study – Scenario : Showroom in Mumbai
Peak Load and Part Load conditions prevailing for the year are assumed as follows :
100 % ( Peak ) Internal Load – 01 Months
70 % ( Part ) Internal Load – 09 Months
60 % ( Part ) Internal Load – 02 Months
* Duty Factor for Cutoff at Part Load Conditions for Fixed Speed Units ~ 0.80
* Power Consumption / TR for Fixed Speed Units ~ 1.30
* Cost of per unit of Electrical consumption = Rs 6.00
Total No of units required for the project as per Heatload & Design : 05 nos 4.0 TR
Cassette units
No of units x
power consumed
Formula - Total Power Consumed per hour x no of Formula = 05 x 10
working hours in x 30 x (01x4.0 +
year x duty factor 09x2.2 + 02x1.825)
Peak Load and Part Load conditions prevailing for the year are assumed as follows :
100 % ( Peak ) Internal Load – 01 Months
70 % ( Part ) Internal Load – 09 Months
60 % ( Part ) Internal Load – 02 Months
* Duty Factor for Cutoff at Part Load Conditions for Fixed Speed Units ~ 0.80
* Power Consumption / TR for Fixed Speed Units ~ 1.10
* Cost of per unit of Electrical consumption = Rs 6.00
Total No of units required for the project as per Heatload & Design :
Option A : 02 nos 7.5 TR + 01 nos 5.0 TR Ducted Split units (Carrier / BS / VL )
Option B : 05 nos 48K Digital Inverter Cassette units
1
Toshiba Inverter Multi – Product Line up
Duct Type
10K , 13K , 16K , 22K
High wall
10K , 13K , 16K , 22k
Toshiba Inverter Multi – Key Features
Best suited for the High End Residential –Apartments & Compact Offices ,
• the operational “Diversity” is maximum and
• outdoor space is limited
3
Toshiba Inverter Multi – Hybrid Inverter Technology
3
Toshiba Inverter Multi – Vector IPDU & Twin Rotary Comp
3
Toshiba Inverter Multi – Wide Capacity Range
For Example – 23K odu can have capacity from 0.4TR – 2.0 TR
7kW
7.0 kW
Capacity
1.4 kW
0
A B r.p.s.
Compressor Revolution
Each of the unit has a Wide Capacity range of operation and thus facilitates
designing for Room-Room diversity
18
3
Toshiba Inverter Multi – Fully Featured Remotes
Peak Load and Part Load conditions prevailing in city - Virtue of Outdoor Ambient
Temperature Fluctuations for the year are assumed as follows :
100 % ( Peak ) Internal Load – 01 Months
70 % ( Part ) Internal Load – 09 Months
60 % ( Part ) Internal Load – 02 Months
* Duty Factor for Cutoff at Part Load Conditions for Fixed Speed Units ~ 0.80
* Power Consumption / TR for Fixed Speed Units ~ 1.30
* Cost of per unit of Electrical consumption = Rs 5.00
Total No of units required for the project as per Heatload & Design :
Option A : 03 nos 2.0 TR + 03 nos 1.5 TR + 02 nos 0.75 TR Hiwall Units ( T / DK )
Option B : 03 nos 22k + 03 nos 16k + 02 nos 10k Invereter Multi Hiwall Units with
03 nos 30k Outdoor unit I.e. Variability = 149%
Note – Selection of Inverter Multi Indoor units to a particular Outdoor unit is as per
the combination chart furnished in the catalogue.
Installation Charges are considered same for calculation purposes.
Option A Option B
Assumed Costs : Fixed Speed units as per UKP series, IM odu @ Fixed Speed Inverter Multi Hw
100000 and idu taken @ 25000/unit
Thus Pay Back Period for Additional capital Costs ( 170000 / 120052 ) = 1.41 which is only
for the Toshiba Digital Inverter Cassette Option is :- 17 months