Vous êtes sur la page 1sur 37

ANALYSIS AND DESIGN OF MULTISTOREY RESIDENTIAL

BUILDING USING STAAD-PRO

BY
DEVARAJ NAYAK B C

Internal guide External guide


Mr. BHARATH H Mr. RAMESH G
Assistant Professor Structural Engineer
Dept of Civil Engineering R SQUARE STRUCTURE
BRCE, BANGLORE BANGLORE
 INTRODUCTION

 COMPANY PROFILE

 ABOUT STAAD PRO SOFTWARE

 WORK CARRIED OUT IN MY PROJECT

 MANUAL DESIGN OF STRUCTURAL ELEMENTS

 CONCLUSION
R Square Structural Consultant and Associates
Proprietor:Mr. Ramesh G
Profession:BE (civil), M Tech (Structural Egg.)
About company: Provide world class quality services adhering to
IS, AISC and BS standards in structural design and steel detailing
of residential, commercial and industrial structures.
Services.
•Structural analysis and detailing.
•Construction planning andmanagement.
•Proof checking
•Repairs and rehabilitation.
•Civil engineering consultants
TEAM:

ONGOING PROJECTS: FOUNDER

Dollars paradise apartment: sai guru mukund palazzo


 STAAD or (STAAD.Pro) is a structural analysis and
design computer program originally developed by
Research Engineers International at Yorba Linda, CA in
1997. In late 2005, Research Engineers International
was bought by Bentley Systems.

STAAD PRO LOGO


1. BASIC GEOMETRY
2. SECTION PROPERTIES
3. MATERIALS CONSTANTS
4. MEMBER SPECIFICATIONS
5. SUPPORTS
6. LOADS
7. ANALYSIS INSTRUCTIONS
8. POST PROCESSING COMMANDS
9. DESIGN COMMANDS
WORKED CARRIED OUT IN MY PROJECT

1.Type of building: Multi-storey residential building.


2.No of floors: G+3
3.Each floor height: 3m
4.Loads on building: Dead load, Live load, Floor Load and
combination of loads
5.Column Size: 150x450mm
6.Beam Size: 150x450mm
7.Slab Thickness: 125mm
8.Software used in analysis: STAAD Pro V8i
9.Code Books Followed: IS 456:2000, SP 16
PROCEDURE
Staad pro start up page
BASIC GEOMETRY:
PLAN AND ELEVATION :
It shows the elevation of a g+3building representing the front view which
gives the overview of a building block. Floor to floor height is 3 m.
MEMBER SPECIFICATION:

•The beam size fixed is 150x450 mm, the member specification is


assigned to the respective beams in the structure.
•The column size 150x450 mm, the member specification is assigned to
the respective columns in the structure.

•The column size 150x300mm


3D VIEW OF THE STRUCTURE:
LOAD CONDITIONS AND STRUCTURAL SYSTEM RESPONSE:
1. Dead Loads:
Dead load= self weight= -1
-ve sign indicates that floor load is acting downwards.
2. Live Loads:

For our structure live load is taken as 2 KN/m for design.


Slab load:

Slab load = slab thickness x density of concrete


= 0.15 x 25 = 3.75 KN/m
Factored load = 3.75 x 1.5 = 5.625 KN/m
ANALYSIS OF STRUCTURE:

Structure is analysed by taking all the above combinations


Beam moments

Column moments
MANUAL DESIGN OF STRUCTURAL ELEMENTS
AUTO CADD DRAWINGS
CONCLUSION

1. Analysis and design using STAAD.PRO consumes less time


hence this can be highly useful for quicker work &time bound
projects.
2. Reinforcement Detailing Drawing is generated along with the
result automatically by STAAD.PRO.
3. Proposed sizes of the elements can be used in the structure.
4. Reinforcement area graph helps in achieving economy in
material used.
5. STAAD.PRO enables to check the safety of design and
modification in individual structural element.
6. The structural components of the building are safe in shear and
flexure.
7. Amount of steel provided for the structure is economic.
REFERNCES
• IS 456-2000
• SP 16
• IS 875 PART 1
• IS 875 PART 2
• IS 875 PART 3
THANK