660 MW x 3 Unit
CONTENTS
• Importance of Efficiency
• What is Thermal cycle Efficiency
• How to Increase Cycle efficiency
• What is Super critical Boiler
• Sipat Super Critical Boiler
• Comparison of Super Critical Over
Sub Critical
QUEST FOR EFFICIENCY IMPROVEMENT
S
THERMAL EFFICIENCY OF RANKINE CYCLE
Q -Q
1 2W Useful work
• η = ------- = --- = ----------------
Q 1 Q Heat supplied
Rejected Heat
• η =1- --------------------
Useful Heat
T -T 1 T 2 2
P2
S
T-S Diagram for a Supercritical
Cycle
WHY SUPERCRITICAL PRESSURE
• The purpose of having high inlet steam pressure
for turbine can be inferred from Previous
deliberations.
• A Boiler operating at a pressure above critical
point is called ‘SUPERCRITICAL BOILER’
• A point where boiling water and dry saturated
lines meet so that associated latent heat is zero,
this point is called Critical Point and occurs at 225
kg/cm2 (abs) 374.15º C temperature.
SUPERCRITICAL BOILER
• Supercritical pressure boiler has no drum and heat
absorbing surface being, in effect, one continuous
tube, hence called ‘once through Supercritical
pressure boilers.’
• The water in boiler is pressurized by Boiler Feed
Pump, sensible heat is added in feed heaters,
economizer and furnace tubes, until water attains
saturation temperature and flashes instantaneously
to dry saturated steam and super heating
commences.
SH
DRUM RISERS
BFP HTR ECO
DOWN COMER
SH
SEPERATOR
W/WALL
BFP HTR ECO
ENTROPY
COMPARISION OF THERMAL CYCLE
EFFICIENCIES.
2. Spirally wounded
evaporators for safe
1. Large Single Funace
and reliable evaporator
- Horizontal - FUR.
- SIDE (SPIRAL & VERT.) - B/P. ROOF - - PLATEN - FINAL
- Pendant - FRONT & REAR (SPIRAL & ROOF
- B/P. FRONT & REAR
DIVISION
STORAGE TK
VERT.) - B/P SDIDE (R.L)
- EXT. FLOOR &
SIDE(R.L)
LT R/H HT R/H
(Coil)
B Y O T H ER
BLR WTR fill in from F/W HTR
No.8
- PLATEN - FINAL
B Y O T H ER D S
B Y O T H ER D S
HP IP GENERATO
TB TB R
LP
B Y O T H ER
TB
DS
B Y O T H ER
BWR
P
CW in
CONDENSO
R CW
SUMMARY OF TOTAL TONNAGE BOILER
( 660 MW)
TOTAL
SL ACTIVITY DESCRIPTION QTY MT
1 STRUCTURAL STEEL & BUILDING 6924
2 BOILER PROPER & ACESSORIES 7080
3 REFRACTORIES, INSULATION & CLADDING 1410
4 POWER CYCLE PIPING 3032
5 STEAM BLOWING SYSTEM 54
6 COAL FIRING SYSTEM 3273.00
7 DRAFT SYSTEM 5004
8 FUEL OIL & FIRING SYSTEM 80.00
9 MISCELLANEOUS 130
10 ELECTRICAL & INSTRUMENTATION 277
GRAND TOTAL OF SG & AUXILIARIES 27264
Pressure Parts Material
Material Oxidation
Section SIPAT Criteria,
Economizer Tube SA210C ℃
Spiral SA213T22 SA-210C 454
Evaporator
Tube Vertical SA213T22 SA-213T2 482
Primary SA213T23, T91
Super heater SA-213T12 552
Tube Secondary SA213T12, T23, T91
SA-213T22 593
Final SA213T23, T91, T92
Primary SA210C, T12, T23 SA-213T23 593
Reheater
Tube Final SA213T23, T91 SA-213T91 649
SUPER304H
Separator SA302C SA-T92 649
SH outlet SA335P91
Header SUPER304 760
RH outlet SA335P91
H
STEAM PARAMETERS UNDER BMCR CONDITION
SL DESCRIPTION
Vertical Panel
Lifting
Ground
3/3/’05 9/16/’05 10/15/’06
Assembly
Structural Hanger Rods Bundle Ground Links & Fitting & Hydro Test
Steel (Milestone) Assembly Connections Welding HP Part
Spiral& Hopper
Ground ass’y Lifting
Hydro Test
IP/LP Part
(Milestone)
Connection
Lift Windbox
Duct
3. Overall Site Erection & Commissioning Flow Chart
Refractorie
s
MS Piping Insulation
& Cladding
Misc.
System
Evaporator Design For Sipat
Supercritical Boiler
• Upper Part
Vertical Wall
• Lower Part
Spiral Wall
2. Evaporator Wall Construction (2/3)
• Spiral wall
• Vertical wall
Horizontal buckstay
Temp. distribution at
evaporator outlet
Heat distribution at
evaporator
Erection complication
Application
1. Minimum once-thru load : 30%
2. Heat recuperation : Circulating Pump
3. No of separator : Two
storage tank : One
SIPAT Boiler Design
Tangential Firing System
Characteristics :
1. 40 Nos ( 4 corners x 10 levels) of Tangential firing Low NOx burner
2. Max. NOx Emission: 260 g/Gj (360 ppm)
3. Max. unburned carbon loss 1.5%
SIPAT Boiler Design
High performance mills
Characteristics :
1. Number of Installation: 10sets (Design Coal: 7sets,Worst Coal: 9sets operation)
2. Verticl Bowl Type
3. Static Classifier ( 70% fineness thru 200mesh)
4. Design Capacity: 81.5 Ton/hr
III.COMPARISON OF SUPER AND SUBCRITICAL
1.Itemwise comparison
1) Definition
2) Power Plant Efficiency
3) Design / Performance
4) Manufacturing / Erection
5) Operation
6) Maintenance
2. Technical Feature
– Operating pressure:
– Operating pressure: below
• 1.Definition above critical point 225.5
critical point 225.5 kg/cm2g
kg/cm2g
* Addition cost to
manufacture and erect
furnace wall only
- Manufacturing : 2~3%
- Erection : max. 5%
1.Itemwise comparison
• SUPERCRITICAL (ONCE-THRU) • SUBCRITICAL (DRUM)
– No difference : – Base
• 6.Maintenance
( based on the experience of
500MW Korean standard
units)
2. Technical
4. Improved steam flow distribution ay lower loads in the superheater and reheater because
of the higher specific volume of the steam at lower pressures
3. Initial Capital Cost
Thank You