Vous êtes sur la page 1sur 27

ENERGY AUDIT

METHODOLOGY FOR
FOR TURBINE CYCLE
Presented By
M.V.Pande
Dy.Director
NPTI, Nagpur
COAL TO ELECTRICITY PROCESS
STEAM CYCLE FOR 210 MW UNIT
EFFECT OF STEAM PARAMETERS
P1 P2 P1
P3 P1 P2
T2
T1 T3
T2 T1
H
T1
H H

S S
S

Effect of Increasing Effect of Increasing Effect of Increasing


Pressure on Available Steam Temperature Steam Pressure &
Energy On Available Energy Temperature Both on
Available Energy
EFFECT OF STEAM PARAMETERS

H
H

S S

Effect of Changing Reheat Pressure Effect of Changing Reheat Temp.


THERMAL PROCESS LOSSES
Impact of Turbine Cylinder Efficiency on
HR/Output

Description Effect on Effect on


TG HR KW

1% HPT Efficiency 0.16% 0.3%

1% IPT Efficiency 0.16% 0.16%

1% LPT Efficiency 0.5 % 0.5 %

FOLLOW TEST CODES

• ASME PTC - 6 For Steam Turbines

• ASME PTC - 4.1 or BS- 845: 1987 for Boilers


210 MW KWU STEAM TURBINE STEAM & WATER CYCLE
TURBINE CYCLE LOSSES
STEPS INVOLVED IN CONDUCTING THE
TURBINE ENERGY AUDIT

Data collection
Observations and Analysis
Exploration for energy conservation
measures
Report preparation
DATA COLLECTION
Design Specification of turbine and associated equipment:

 Type of the turbine, make and model


 Number of cylinders
 No of stages (for HP, IP and LP)
 No of main and reheat valves
 Construction details of HP, IP LP
 Turbine extraction systems
 Control systems
 Type of governing
 Type of sealing
 Year of installation
 Major modifications carried out during the recent past
DATA COLLECTION

Turbine Cycle Heat Rate Kcal/kwh


DATA COLLECTION
INSTRUMENTS REQUIRED

 Temperature Indicator & Probe


 Pressure gauges
 Flow measuring instrument (steam and
water)
 Ultrasonic leak detector
MEASUREMENTS & OBSERVATIONS TO BE MADE
 Feed water at Inlet & Outlet of Heaters
Main steam parameters
Pressure
 HP turbine extraction
Temperature
 Hot reheat steam, Cold reheat Steam
Flow
 IP extraction
 IP Exhaust
 Condenser back pressure
 Cooling water flow and temperatures
 Generator output
 Barometric pressure
 Reheater spray (flow)
 Superheater spray (flow)
 Feed water (flow)
MEASUREMENTS & OBSERVATIONS TO BE MADE
 Past performance trends on turbine loading,
operation, PLF
 Major constraint in achieving the high PLF, load or
efficiency
 Major renovation and modifications carried out in the
recent past
 Operational failures leading to inefficient operation
 Tripping
 Performance of associated equipment (condenser,
boiler, etc)
 Plant side initiatives to improve the performance and
efficiency of the Turbine
TURBINE HR EVALUATION AND EFFICIENCY
 Turbine heat rate is defined as the heat input (Kcal) required
to generate one unit of Electrical output (KWh). The trials are
to establish heat rate (Kcal/kWh) and turbine efficiency under,
as run conditions have to be carried out
 The efficiency method given in this procedure is the
enthalpy drop efficiency method. This method determines the
ratio of actual enthalpy drop across turbine section to the
isentropic enthalpy drop
 This method provides a good measure for monitoring
purposes. Each section of the turbine must be considered as
a separated turbine
 Each section should be tested and results are trended
separately. While conducting the tests, it has to be ensured
that, it is conducted over normal operating load range
TURBINE HR EVALUATION AND EFFICIENCY

Q1 x (H1 – h2) + Q2 X (H3 – H2)


Turbine Heat Rate =
Gross Generator Output

860 kW
Turbine Cycle Efficiency = X 100
Heat Rate kCal/hr
TURBINE HR EVALUATION AND EFFICIENCY

Actual
Process
1-2-3-4-5

Comparison of Actual Expansion Actual Expansion in HP, IP & LP


with Isentropic Expansion in Turbine Cylinder
TURBINE HR EVALUATION AND EFFICIENCY

Variation of Heat Rate with Load Heat Rate Characteristics with


Condenser Exhaust Pressure
TURBINE EFFICIENCY EVALUATION DATA

Kcal/kg/oK
Effect of Condenser Vacuum on
Heat Rate

10 MM HG IMPROVEMENT IN
CONDENSER VACUUM
LEADS TO 20 Kcal/kwh (1%)
IMPROVEMENT IN HEAT RATE FOR A
210 MW UNIT
EFFECT ON HEAT RATE FOR PARAMETER
DEVIATION (500 MW UNIT)
DEVIATION IN PARAMETER EFFECT ON HEAT
RATE (KCAL/KWH)
1. HPT inlet press. by 5.0 ata 6.25
2. HPT inlet temperature by 10.0 deg C 6.0

3. IPT inlet temperature by 10.0 deg C 5.6

4. Condenser pressure by 10.0 mm of Hg 9.0


5. Re spray water quantity by 1.0% 4.0
6. HPT Cylinder efficiency by 1.0% 3.5
7. IPT Cylinder efficiency by 1.0% 4.0
EFFECT OF DEVIATION IN PLANT
PARAMETERS (210 MW UNIT)
Cause Effect
1% increase in plant efficiency - 3% reduction of coal consumption
- 3% reduction of CO2
200C reduction in M.S. temp. -1% loss of turbine cycle efficiency
25Kg/cm2 reduction in M.S. Pr. -1% loss of turbine cycle efficiency
10C CW inlet temperature rise 5 kCal/Kwh heat rate increase
10 mm deterioration in 20 kCal/Kwh heat rate increase
condenser vacuum
1 HP Heater out of service 50 kCal/Kwh heat rate increase
1 LP Heater out of service 25 kCal/Kwh heat rate increase
- 5% excess air - 1% O2 Increase in flue gas
- Every 20% excess air - 1% loss of boiler efficiency
200C increase in exit gas temp. - 1% loss of boiler efficiency
IDENTIFYING FACTORS FOR HR DEVIATION
After evaluating the turbine heat rate and efficiency, check
for the deviation from the design and identify the factors
contributing for the deviations. The major factors to be
looked into are:
 Main steam and reheat steam inlet parameters
 Turbine exhaust steam parameters
 Reheater and super heater spray
 Passing of high energy draining
 Loading on the turbine
 Boiler loading and boiler performance
 Operations and maintenance constraints
IDENTIFYING FACTORS FOR HR DEVIATION

 Condenser performance and cooling water parameters


 Silica deposition and its impact on the turbine efficiency
 Inter stage sealing, balance drum and gland sealing
 Sealing fins clearances
 Nozzle blocks
 Turbine blade erosion
 Functioning of the valves
 Operational status of HP heaters
 Performance of reheaters

Vous aimerez peut-être aussi