INTRODUCTION
Load calculation
Interpretation of results
Comparison of results
Study of oblique column in steel framed 9
12 January 2020
multi-storied building using ETABS
Details
• G+10 steel framed high rise building is considered for
analysis.
Building Details
Plan Dimension 36m x 36m
Type of building SMRF
Total height of the building G+10=33m
Height of each storey 3m
Depth of foundation 3m
Size of beams ISLB 150
Size of normal column ISLB 150
Size of oblique column of 700 ISHB 350
inclination
Seismic zone IV
70 228.8 759
75 211 616.3
80 77.9 480.5
85 62 392.3
90 1049.4 3344.3
70 37257.4501 31026.0773
75 19474.4353 21856.0326
80 3701.7678 4096.1302
85 767.8697 800.1582
90 38766.6412 32421.3482
3500 3344.3
3000
Displacement (mm)
2500
2000
x
1500 y
1049.4
1000 759
616.3
480.5 392.3
500 228.8 211
77.9 62
0
70 75 80 85 90
Column inclination (degrees)
0.05
Storey Drift
0.04
0.03 70
75
0.02
80
0.01 85
90
0
storey storey storey storey storey storey storey storey storey storey storey
1 2 3 4 5 6 7 8 9 10 11
Storey Level
0.4 70
0.3 75
80
0.2 85
0.1 90
0
storey storey storey storey storey storey storey storey storey storey storey
1 2 3 4 5 6 7 8 9 10 11
Storey Level
25000
21856.0326
19474.4353 x
20000
y
15000
10000
5000 3701.7678 4096.1302
767.8697 800.1582
0
70 75 80 85 90
Column inclination (degrees)