Académique Documents
Professionnel Documents
Culture Documents
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
GSM SYSTEM
GENERAL NETWORK ARCHITECTURE
MS (Mobile Station)
MS
BTS
BSS (Base Station System)
BSC
PSTN,ISDN...
MSC
NSS (Network Switching
Voicemail Server
Subsystem)
SM-SC VLR HLR AuC EIR
OMC OMC
OMM(Operations & Maintenance
NMC GSM interfaces
X.25 links Management)
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
ZXG10 BSS STRUCTURE
Um
Abis Q3
BTS
B B
I I
E E
MS OMC-R
BSC
Ater A
BTS SM SM TC MSC
Gb
BS Interface
SGSN
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
BTS HARDWARE PRINCIPLE
Abis Interface Um Interface
Data Modulated
Link Signal
B O B Demodulated R A
S Signal RR
C M P F P
Control Signal
U U signal U U
System System
Clock Clock
PDU
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
ZXG10-BTS(V2)
System
Architecture
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
ZXG10-BTS V2
General Description
• Capacity: 12 TRX Per Rack.
• Power output: 40W/80W
• Receive sensitivity: -108dBm
• Largest site type: S12/12/12 or O36
(3 cabinets, 40W)
• Largest site type: S6/6/6 or O18
(3 cabinets, 80W)
• Max. Power consumption : ~2200W
• Grounding Resistance : <5 ohm
• Rack Dimension : 1600mm×600mm×550
mm (H x W x L)
• Power Supply: +24V or –48V
• Environment Temperature: -5℃~ +55℃
• Relative Humidity: 15% ~ 85%
• Weight: ~300kg (Complete product)
• Application : Indoor type macro cell
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
BTS HARDWARE CONFIGURATION
TRM 1
.
MMI CMM .
. Um
Abis .
A
BSC PDM TRM 6 E
.
M
.
.
FCM .
TRM 12
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
BTS HARDWARE CONFIGURATION
MAIN MODULES OF ZXG10 –BTS V.2
2. TRM:Transceiver Module
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
BTS HARDWARE CONFIGURATION
CMM CMM
PDM PDM
CMM CMM
FCM FCM
S
S S S
C
C T T T T C C
T P T P
D
D R R R R D D
R A R A
U M M M M U U G G G G U
FCM FCM
S S S S C
T T T T C C
C T P T P D
R R R R D D
D R A R A
M M M M U U U
U G G G G
FCM FCM
C S S S S C
C T T T T C
D T P T P D
D R R R R D R A R A
M M M U U
U M U G G G G
Single Rack Figure
80 W
40 W
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
BTS HARDWARE CONFIGURATION
EXPANSION
BTS#3 BTS#1 BTS#2
CM M CM M CMM
PDM PDM PDM
CM M CM M CMM
风 机层
FCM 风 机层
FCM 风FCM
机层
C T T T T C C T T T T C C T T T T C
D R R R R D D R R R R D D R R R R D
U M M M M U U M M M M U U M M M M U
风机层
FCM 风机层
FCM 风FCM
机层
C T T T T C C T T T T C C T T T T C
D R R R R D D R R R R D D R R R R D
U M M M M U U M M M M U U M M M M U
风 机层
FCM 风 机层
FCM 风 FCM
机层
C T T T T C C T T T T C C T T T T C
D R R R R D D R R R R D D R R R R D
U M M M M U U M M M M U U M M M M U
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
CMM HARDWARE
Indicator
Light Test Reset
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
CMM MODULE FUNCTIONS
1. BS interface functions
2. Providing various clocks needed by BS
3. Remote operation & maintenance function of BTS
4. Local operation & maintenance functions of BTS
5. Equipment alarm collection
6. Active/standby hot backup
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
CMM MODULE STRUCTURE
BS interface unit
Switching unit
Line interface
BS interface
Relay array
Abis TO TRM
CLK-ref CLK
Master/slave
Clock unit
controller interface unit
Main
unit
Environment
MMI unit
monitoring unit
Power supply
unit
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
EXTERNAL INTERFACES OF CMM (1)
• Abis interface
• Test interfaces
• Panel interface
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
EXTERNAL INTERFACES OF CMM (2)
• Active/standby interfaces
• MMI
• Power interface
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
DIPSWITCH OF CMM (1)
11 11
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
DIPSWITCH OF CMM (1)
BTS_NO: rack No. in the same site (00-master rack, 01-slave rack 1, 10-slave rack
2)
SLAVE1_PORT: master rack E1 port used to connect slave rack 1 (00-master rack
C port, 01-master rack D port, 10-master rack E port, 11-master rack F port)
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
DIPSWITCH OF CMM (2)
SLAVE2_PORT: master rack E1 port used to connect slave rack 2 (00-master rack C
port, 01-master rack D port, 10-master rack E port, 11-master rack F port)
SATE: whether to use the satellite Abis link (0 indicates the ordinary Abis, and 1 indicates the
satellite Abis)
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
TRM INTRODUCTION
T R M 发 射
Transmitter
Indicator指light
示 灯
T X
把 handle
手
接Receiver
收
复
Reset 位 R X
R S T R X D 分Diversity
集 接 Receiver
收
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
TRANCEIVER MODULE 40W and 80W
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
TRM INTRODUCTION
Downlink Signal
PAU
Uplink Signal
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
TRM PANEL DESCRIPTION
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
ANTENNA EQUIPMENT MODULE (AEM)
Tx
TRM
GROUP AEM
Rx
RxD
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
ANTENNA EQUIPMENT MODULE TYPES
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
INTRODUCTION OF CDU (1)
L N A _ S p litte r ER X 1
ER X 2
D u p le x e r
C a b le R x _ in R X 1
A N T R X 2
R X 3
C a b le
R X 4
A la rm s
R TE
fo rw a rd re v e rse
o p tio n a l Tx_out
TX 1
V S W R _ m e te r
50ohm TX 2
H y b ird _ c o m b in e r
A la rm s
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
INTRODUCTION OF CDU (2)
CDU (Combiner Distribution Unit)
Combiner Input
CDU
Ext Receive
TX1
TX2
D
1 to 4
Test Port U
Divider
Indicator P
TEST L
E
Antenna ANT 2 to 1
X
RX1 Combiner
RX2 Divider Output E
RX3 R
RX4 Divider Ext Output
EX1
EX2
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
INTRODUCTION OF DCDU
L N A _ S p litte r
R X 1
D u p le x e r
C a b le R x _ in
A N T
R X 2
C a b le
A la rm s
R TE
fo rw a rd re v e rse
o p tio n a l
IT X
V S W R _ m e te r
A la rm s
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
INTRODUCTION OF ECDU
LNA_Splitter
Duplexer Cable Rx_in RX1
ANT RX2
Cable
Alarms
forward RTE
reverse
optional ITX
VSWR_meter
Alarms
LNA_Splitter
Rx_filter Cable Rx_in RXD1
ANTD
RXD2
Alarms
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
INTRODUCTION OF RDU (1)
ER X 1
R x _ filte r L N A _ S p litte r
ER X 2
A N T C a b le R x _ in R X 1
R X 2
R X 3
R X 4
50ohm
A la rm s
R TE
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
INTRODUCTION OF RDU (2)
RDU
Antenna
天 线
ANT 分 路Distribution
器 输出
RX1
Output
RX2
RX3
Indicator light
指 示 灯
RX4
EX1
EX2 分 路 Distribution
器 输 出扩 展
Extension Output
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
INTRODUCTION OF CEU (1)
R x _ S p litte r
RX1
ERX1
RX2
RX3
ERX2
RX4
50ohm TX2
H y b ird _ c o m b in e r
H y b ird _ c o m b in e r
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
INTRODUCTION OF CEU (2)
CEU (Combiner Extension Unit)
TX3
Divider Output 2 to 1 Combiner
TX4
OTX2 RX1
RX2
2 to 1 Combiner
RX3 Divider Ext Output
RX4
EX1
EX2
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
ZXG10-BTS V.2 AEM CONFIGURATION
1 2 0 7 2 2
2 2 0 8 2 2
3 2 0 9 4 1
4 2 0 10 4 1
5 2 1 11 4 2
6 2 1 12 4 2
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
ZXG10-BTS V.2 BASIC CONFIGURATION
T X /R X T X /R X
C D U C D U
TX 1 TX 2 RX 1 R X 2 R X 3 RX 4 TX 1 TX 2 RX 1 R X 2 R X 3 RX 4
O4
TX R X R X D TX R X R X D TX RX R X D TX RX R X D
TR M 1 TR M 2 TR M 3 TR M 4
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
ZXG10-BTS V.2 BASIC CONFIGURATION
T X /R X T X /R X
R X 1 R X 1
CDU R
R
X
X
2
3
R
R
X
X
2
3
CDU
TX1 TX2 EX1 EX2 R X 4 R X 4 TX1 TX2 EX1 EX2
O8 O TX1 OTX1
CEU
TX1 TX2 TX3 TX4 RX1 RX2
EX1
RX3
EX2
RX4
OTX1 OTX1
RX 3
EX2
RX4
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
ZXG10-BTS V.2 BASIC CONFIGURATION
T
T R M1 R
R
O12 T
T R M2 R
R
T
T R M3 R
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
R
FAN CONTROL MODULE FUNCTIONS
• Temperature monitoring
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
PDM POWER SUPPLY MODULE
CMM
PDM backplane
FCM
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
BTS V.2 POWER CONSUMPTION
TRM: 140W
AEM: 70W
CMM(2): 20W
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
TOP CONFIGURATION
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
INTERFACE AND COMMUNICATION
M Interface
External
Um Interface
Monitoring
System
B
Interface
BSC
Abis Interface
Tower Mounted
Amplifier
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
FRAME STRUCTURE OF Abis INTERFACE
TS 0 1 2 3 4 5
16 :7 1 multiplexing
0 SYNC
1 TRX1
2 TCH0 TCH1 TCH2 TCH3
3 TCH4 TCH5 TCH6 TCH7
4 TRX2 SYNC : Synchronous time slot
5 TCH0 TCH1 TCH2 TCH3
6 TCH4 TCH5 TCH6 TCH7
7 TRX3
8 TCH0 TCH1 TCH2 TCH3
9 TCH4 TCH5 TCH6 TCH7
10 TRX4 TRX : LAPD signaling channel of radio
11 TCH0 TCH1 TCH2 TCH3 carrier
12 TCH4 TCH5 TCH6 TCH7
13 TRX5
14 TCH0 TCH1 TCH2 TCH3
15 TCH4 TCH5 TCH6 TCH7 OMU : LAPD channel of OMU,
16 O+M1
17 TRX6 mainly includes configuration and
18
19
TCH0
TCH4
TCH1
TCH5
TCH2
TCH6
TCH3
TCH7
O&M information of all BTSs
20 TRX7
21 TCH0 TCH1 TCH2 TCH3
22 TCH4 TCH5 TCH6 TCH7
23 TRX8
24 TCH0 TCH1 TCH2 TCH3 TCH : Traffic channel, occupying 2
25 TCH4 TCH5 TCH6 TCH7
26 TRX9
bits, 16kb/s
27 TCH0 TCH1 TCH2 TCH3
28 TCH4 TCH5 TCH6 TCH7
29 O+M4
30 O+M3
31 O+M2
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
FRAME STRUCTURE OF Abis
INTERFACE
1 : 4 multiplexing
TS 0 1 2 3 4 5 6 7
0 SYNC
1 TRX1 TRX2 TRX3 TRX4
2 TCH0 TCH1 TCH2 TCH3 SYNC : Synchronous time slot
3 TCH4 TCH5 TCH6 TCH7
4 TCH0 TCH1 TCH2 TCH3
5 TCH4 TCH5 TCH6 TCH7
6 TCH0 TCH1 TCH2 TCH3
7 TCH4 TCH5 TCH6 TCH7
8 TCH0 TCH1 TCH2 TCH3 TRX : LAPD signaling channel of radio
9 TCH4 TCH5 TCH6 TCH7 carrier
10 TRX5 TRX6 TRX7 TRX8
11 TCH0 TCH1 TCH2 TCH3
12 TCH4 TCH5 TCH6 TCH7
13
14
TCH0
TCH4
TCH1
TCH5
TCH2
TCH6
TCH3
TCH7
OMU : LAPD channel of OMU,
15 TCH0 TCH1 TCH2 TCH3 mainly includes configuration and
16 O+M
17 TCH4 TCH5 TCH6 TCH7
O&M information of all BTSs
18 TCH0 TCH1 TCH2 TCH3
19 TCH4 TCH5 TCH6 TCH7
20 TRX9 TRX10 TRX11 TRX12
21 TCH0 TCH1 TCH2 TCH3
22 TCH4 TCH5 TCH6 TCH7 TCH : Traffic channel, occupying 2
23 TCH0 TCH1 TCH2 TCH3
24 TCH4 TCH5 TCH6 TCH7
bits, 16kb/s
25 TCH0 TCH1 TCH2 TCH3
26 TCH4 TCH5 TCH6 TCH7
27 TCH0 TCH1 TCH2 TCH3
28 TCH4 TCH5 TCH6 TCH7
29 O+M4
30 O+M3
31 O+M2
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
ZXG10 – BTS VERSION 2 NETWORK
Site 0
BSC Site 1
.
.
.
Site n
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
ZXG10 – BTS VERSION 2 NETWORK
BSC
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
ZXG10 – BTS VERSION 2 NETWORK
Site 1
Site 2
.
. Site 0 Site 3
BSC
.
Site n
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
ZXG10-BTS (V2) INTERNETWORKING
B
B T
T S
S
B
T
S
B
T
S
MSC BSC
B
T B
S T
S
B
T
S
B
T
S
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
ZXG10-BTS (V2) LINK PROTECTION
A C A C A
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited
All the information involved in the file belongs to ZTE. Any kind of releasing without permission is prohibited