Vous êtes sur la page 1sur 8

PF

SMOKE

PNF

A320 - Version 02

PF
1.DETECTION Moderate smoke in the cockpit:

PNF

DETECTION
FLIES THE AIRCRAFT NAVIGATES

PF
2.PROCEDURE : FIRST ACTIONS

PNF

QRH

ORDER. SMOKE/FUMES/AVNCS SMOKE

SMOKE/FUMES/AVNCS SMOKE.....APPLY
1.00

PF
COMMUNICATES Apply: IF PERCEPTIBLE SMOKE APPLY IMMEDIATLY LAND ASAP

These actions have to be applied, regardless of the origin of smoke. They might be displayed on the ECAM.

Keep in mind:  IF DENSE SMOKE, at any time of the procedure:

PF
3.PROCEDURE : AIR COND SMOKE Moderate smoke persists. You suspect AIR COND SMOKE:

PNF

QRH

SMOKE/FUMES/AVNCS SMOKE.....APPLY
1.00

FCOM

3.02.26

FCOM SMOKE/FUMES/AVNCS SMOKE procedure contains some guidelines to determine smoke origin.

Keep in mind:  IF DENSE SMOKE, at any time of the procedure:

Apply:  IF AIR COND SMOKE SUSPECTED:

PF

PNF
4.PROCEDURE : CABIN EQUIPMENT SMOKE

Moderate smoke persist. You suspect now CABIN EQUIPMENT SMOKE: SMOKE/FUMES/AVNCS SMOKE.....APPLY

QRH

1.00

Keep in mind:  IF DENSE SMOKE, at any time of the procedure:

Apply:  IF CAB EQUIPMENT SMOKE SUSPECTED:

PF
Moderate smoke persists. You cannot determine the source

PNF

5.PROCEDURE : SMOKE SOURCE NOT DETERMINED


QRH

SMOKE/FUMES/AVNCS SMOKE.....APPLY
1.00

Keep in mind:  IF DENSE SMOKE, at any time of the procedure:  IF SMOKE SOURCE CANNOT BE DETERMINED AND STILL PERSIST OR:

PF
6.PROCEDURE : DENSE SMOKE

PNF

QRH

Smoke is dense, now.

SMOKE/FUMES/AVNCS SMOKE.....APPLY
1.00

Apply:  IF DENSE SMOKE, at any time of the procedure:

Apply: TO SET ELEC EMER CONFIG

SMOKE/FUMES REMOVAL
QRH

Then, apply ECAM ELEC EMER CONFIG procedure.

1.00

PF

PNF

THE END...