Overview of M2000
M2000, using two kinds of working mode, including client and server terminals. The software of M2000 is made up of client, server and network element adapter, which are independent from each other. Client software runs on client terminal, while the server and network element adapter software run on the server terminal. How do M2000 configure the net? Especially for BSC6000? First, M2000 sends the order, all the configuration data is written into an XML file. Secondary, uploaded to M2000 by FTP, then the configured server will fetch the network elements configuration data according to MIT trees related interfaces of BSC6000. So, without making any operation of data configurations in M2000 we can see all the messages of cells and carrier frequency managed by BSC6000.
Overview of M2000
The functions offered by M2000 are not only the management of performance
counter, but also the centralized managements of topology, configuration, fault, software and safety. Main functions offered by performance counter management: Management of performance counter and objects Real time measurement functions Real time monitoring Management of performance data Performance alarms Custom counter After the connecting between M2000 and BSC6000, BSC will upload a default task file of a network element to M2000 server. M2000 will analyze and verify the format and content of this task file, and then create a new task file according to the measured counter management, finally descend to network element.
Custom counter
Custom counter is a new measurement counter, which is created by portfolio operation of original counter.
Custom counter is made up of value, constant and integral operators. All system counteres involved in a certain custom counter must correspond to a same object type. The formula defined in custom counter can be nested. The length of formula must be less than 255 bytes. User can create, modify or delete custom counter, but cant deliver measurement directly.
All Rights Reserved 2006, Huawei Technologies CO., LTD.
Object Setting
Counter Setting
Others Setting
Get Result
Maintenance and query operation of real time counter is the same as normal counter, but the function entrance
After user login, select the custom counter, and the modify or delete operation will be available
Step1select counter
Step2:click export
How many network elements can M2000 manage How to do if we cant query the counter data
M2000 version
Database platform
Hardware platform
Sun Fire V890 Server8CPU Solaris8+Sybase12 Sun Fire E4900 Server8CPU Sun Fire V890 Server8CPU Solaris10+Sybase15 Sun Fire E4900 Server8CPU Sun Fire V890 Server8CPU Solaris10+Sybase15 Sun Fire E4900 Server8CPU
BSC32+BTS
60mins
40ce lls
No measurement of TRX object; no Neb cell measurement No measurement of TRX object; no Neb cell measurement Default measurement object
TRX object measurement; numbers of Neb cell measurement objects are no more than 15000 half hour period<8000) TRX object measurement; numbers of Neb cell measurement objects are no more than 1500 half hour period<800) Full objects measurement
BSC6000+BT S
60mins
50ce lls
PCU
60mins
60ce lls
1.5
exampleif every BSC6000 set one PCU &300 cells, the number of equivalent network elements is 11(normal measurement) , 19.5(max measurement) B065 version of V890 can suspend 11(normal) / 6(max) BSCs.
All Rights Reserved 2006, Huawei Technologies CO., LTD.
archive.
Some appraisal counteres of customer need to be calculated by custom formula, but the query is very slow, how to do?
Suggest not use custom counter in M2000, export the original counter, write macro/formula ourselves to improve the speed.
MML imported
Import of MML can improve the efficiency of daily data modifying and querying.
Man-machine interface optimized Function persistence optimizing: real time monitor of counter, cooperate with network element to complete less granularity counter monitor. Query report: many sheets can be set in one report, and it can include different measurement object/counter; at the same time, we can set TopN query or conditional display.