Construction 1 Airend
2 Energy-saving electric motor 3 Motor grease nipples 4 Inlet valve 5 Minimum pressure/check valve 6 Combined Auxiliary Vent Valve 7 Fluid cooler with mounted thermostatic valve and fluidmicro filter 8 Compressed air after cooler 9 Two-stage air inlet filter 10 Fluid separator tank with separator cartridge 11 Safety Valve 12 Anti Vibration Dampers 13 Sigma Control
2/25/2012
MUHAMMAD SAJID
2/25/2012
MUHAMMAD SAJID
Fluid Separation
98-99%
2/25/2012
MUHAMMAD SAJID
2/25/2012
MUHAMMAD SAJID
2/25/2012
MUHAMMAD SAJID
Tasks of Fluid
First task:
Heat transfer, discharge temp. approximately 75 - 80 oC
Lubrication of Airend Bearings Sealing gap between rotors and casing, prevention of metallic contact absorbing dust, sulphur, etc.
2/25/2012
MUHAMMAD SAJID
Inlet Valve
2/25/2012
MUHAMMAD SAJID
2/25/2012
MUHAMMAD SAJID
2/25/2012
MUHAMMAD SAJID
2/25/2012
MUHAMMAD SAJID
2/25/2012
MUHAMMAD SAJID
2/25/2012
MUHAMMAD SAJID
2/25/2012
MUHAMMAD SAJID
Thermostatic valve The purpose of the thermostatic valve is to bring the cooling fluid up to operating temperature as quickly as possible and to keep it at this level under all operating conditions (idle running, winter operation, etc.). This keeps the compressed air/fluid mixture above the pressure dew point**, preventing condensation in the fluid separator tank. Water in the fluid circuit leads to corrosion in metal parts and reduces the cooling and lubricating qualities of the fluid. Operating temperature, determined by the choice of working element within the thermostatic valve, is dependent on the pressure range and the climatic zone in which the compressor is used. ** Pressure dew point is the temperature at which the air is saturated with moisture. If the air picks up any more moisture it is precipitated out as water (condensate). II Fluid filter The valve also serves as a filter head to which a spin-on element is attached. The element is mounted directly on the valve outlet so that 100% of the fluid flow is filtered before returning to the airend. Direct mounting avoids the need for connecting pipes.
2/25/2012
MUHAMMAD SAJID
2/25/2012
A Cold fluid Fluid flows from the separator tank to the valve inlet(1). When the fluid is cold, the working element (2) and the actuating piston (3) remain in their initial positions. The fluid flows past the cooler through the bypass (4) (as the cooler presents a higher resistance to the fluid than the bypass, the fluid takes the path of least resistance). The fluid flows through the fluid filter (5) directly to the airend (6). In this way, it reaches operating temperature in the shortest possible time. B Warm fluid The fluid flows from the separator tank to the valve inlet (1). The heated fluid flows around the thermostatic working element (2). The working element forces the actuating piston (3) downwards. The passage to the bypass (4) narrows continuously and some of the fluid flows through the cooler. When the fluid reaches operating temperature, the actuating piston (3) is forced down completely by the working element (2). The bypass (4) is closed. All the fluid is routed through the cooler. The fluid flowing out of the cooler is fed to the filter (5). Cooled and filtered fluid is now routed directly to the airend (6).
MUHAMMAD SAJID
Sigma Control
2/25/2012
MUHAMMAD SAJID
Preselect functions
2/25/2012
MUHAMMAD SAJID
Menu-functions UP key Scrolls the display text downard line for line DOWN key scrolls the display text upward line for line
Escape key returns to next higher level Return key initiates jump to next sub-menu or accepts value
Acknowledge key acknowledges alarms andwhen permitted - resets the alarm memory Info key access to additional information or to the event information memory.
2/25/2012
MUHAMMAD SAJID
COSTS COSTS
2/25/2012
MUHAMMAD SAJID
Condensate separation
To ensure sufficient separation, liquids and heavy particles are subjected to centrifugal forces at high rates of flow. The degree of separation is around 95% at 6 bar, 20 C and the nominal volumetric flow rate. The pressure drop is approximately 0.05 bar .
air inlet
air outlet
deflector
Desiccant Dryer
1 2 3 4 Microfilter FE (0.01 m, 0.01 ppm) Flow Distributor Stainless Steel Flow diffuser Desiccant bed: moisture adsorption 5 Upper Part of Dessicant chamber 6 Security Reserve 7 Flow distributor 8 Particulate filter FD 1 m 9 Purge (regeneration ) air valve 10 Desiccant bed: regeneration 11 Purge air exhaust silencer
2/25/2012
MUHAMMAD SAJID
Drying cycle
The incoming compressed air from the receiver tank is filtered by the inlet filter FE (1) from liquid and dust particles (particle size 0,01 m). The air passes through inlet air valve via stainless steel flow distributor (3) where the air is distributed to the whole cross section of the chamber. In the mass transfer zone (4) most of the moisture is transferred to the desiccant granules.The second part of the chamber (5) takes away the remaining moisture to reach the needed dew point. The last part is a security reserve (6). The dried compressed air then flows through the flow distributor (7) and the shuttle valve to the compressed air outlet. Then the air is filtered from dust particles (particle size 1 m) in the dust filter FD (8).
2/25/2012
MUHAMMAD SAJID
Regeneration of desiccant The regeneration is done by a part of the air flow of the dried air of the first chamber. The part air flow is passing through the shuttle valve (9) and going from top down through the second chamber. As expanding air is able to take up moisture, the dry air is regenerating the desiccant (10). The amount of needed regenerating air is a physical size and can be optimised by an adjustable regeneration nozzle (9). The wet purge air is passed through top flow distributor (2), purge air valve and purge air muffler (11) into the atmosphere.
2/25/2012 MUHAMMAD SAJID
dust microscopic
fog:
spray visual
rain
Min.
water mist carbon dust traffic dust cement dust pollen plant spores bacteria metallurgical dust paint spray mist
oil mist
centrifugal separation and filtration performance normal bag-type heavy air filter
2/25/2012
MUHAMMAD SAJID
2/25/2012
MUHAMMAD SAJID
2/25/2012
MUHAMMAD SAJID
Diffusion /Coalescence
2/25/2012
MUHAMMAD SAJID