Académique Documents
Professionnel Documents
Culture Documents
G A S
E Q U I P M E N T
Sequent Plug & Drive is the new system for LPG/CNG conversion developped by BRC.
Designed on the basis of the previous Sequent systems but characterised by a totally new approach of gas flow management.
Main innovation is in the software for engine management. Thanks to its new algorithms, it allows an optimised feeding of gas fuel, in a simply and intuitive way. Some of more advanced functions have been integrated and others have been added in order to simplify the calibration procedure.
Harness
Change-over switch one-touch with buzzer Gas filter FJ1 HE
LPG SYSTEM
B R C G A S E Q U I P M E N T
CNG SYSTEM
B R C G A S E Q U I P M E N T
HARNESS
B R C G A S E Q U I P M E N T
HARNESS
B R C G A S E Q U I P M E N T
To connect
Power Ignition on
Optional
Connection to OBD plug depending on type of connection
Connection
Type PIN
6-7-8-9
CAN BUS 6 - 14
1-2-3
K LINE 7
In case of need
Lambda oxygen sensor OUT External timing advancer (for CNG) RPM signal
HARDWARE INNOVATION
Communication with new change-over switch and PC on same K line Communication with petrol OBD on K line or dedicated CAN Output for timing advancer external unit (for CNG)
SOFTWARE INNOVATION
Totally revised Injection Control Self-mapping Leaning in Open Loop Tip-in / Tip-out and Setup already activated New functions thanks to communication to OBD.
B R C
G A S
E Q U I P M E N T
INSTALLATION SEQUENT PLUG & DRIVE DRIVEABILITY : REFINE TIP-IN, TIP-OUT, RETURN TO IDLE
IS VEHICLE OK?
YES
SELF MAPPING
NO
IS VEHICLE OK?
(TIP-IN, TIP-OUT, RETURN TO IDLE)
NO
NO
IS VEHICLE OK?
(OPEN LOOP condition)
YES
YES
Injection: Calculation
B R C G A S E Q U I P M E N T
+12 V
Petrol INJECTOR
T gas
Gas INJECTOR
+12 V
Step1
Orange Violet TonP
Step2
Step3
Ton G calculation
TonG
Petrol ECU
GAS ECU
MAP
START PROCEDURE
SELECT TYPE EQUIPMENT (Step 1)
SETUP EQUIPMENT AND TYPE OF INJECTORS (Step 2) SAVE FILE .FPD (Step 3) SELF-MAPPING (Step 4) SAVE FILE .FPD (Step 5)
END OF PROCEDURE
B R C
G A S
E Q U I P M E N T
SELF-MAPPING
SELF-MAPPING
B R C G A S E Q U I P M E N T
Start procedure
Idle in petrol
3 accelerations
Sequential Change-over Automatic from Petrol to Gas: 1st Correction Gas Map
Gas Map?
SELF-MAPPING
B R C G A S E Q U I P M E N T
Start procedure
End procedure
Idle in petrol
OK
CHECK DATA GAS MAP
3 accelerations
KO
Switch to Petrol
B R C
G A S
E Q U I P M E N T
Correction at idle
Easy Refinement
Warning!
B R C G A S E Q U I P M E N T
Important concepts Map Refinement Close Loop Idle control: taking into consideration MAP variation and checking
Lambda sensor trend, check that, when switching from petrol to gas, TonP is still the same. When possible, connect EOBD tester to check selfadapting parameters Gear control: check the map with TonP more than that at idle. I.e. 9-10 ms If connection to EOBD plug is present, check the self-adapting parameters Ton Min Gas = value of TonP at idle during gas mode Map parameters: after map refinement, always check that numeric value of Q is negative (<0). If positive, some flow will be delivered by gas injectors even when petrol ECU is in cut-off (TonP=0)
B R C
G A S
E Q U I P M E N T
SETUP
B R C
G A S
E Q U I P M E N T
DRIVEABILITY
B R C
G A S
E Q U I P M E N T
BEFORE STARTING A DRIVEABILITY SETUP, BE SURE THAT GAS FLOW IS CORRECT CHECKING IT BY MAP REFINEMENT.
In the Closed Loop management, the petrol injection supplies the optimal fuel quantity in order to obtain a stoichiometric mixture (QPStoich.). The gas flow (QG) is calculated starting exactly from this petrol quantity.
QPStoich.
QG
In the Open Loop management of the petrol injection, the stoichiometric conditions are usually abandoned in favour of a mixture richer in petrol (QBStoich.+ ENO.L.), of considerable percentages too (for instance 30%).
QPStoich. + ENO.L.
For instance:
QG + ENO.L.
QPStoich. + 30%
QG + 30%
QPStoich. + ENO.L.
QG
On the basis of the parameters acquired during the self-mapping, the strategy recalculates in a independent way the optimal petrol quantity (QPoptimal) needed to keep a rich calibration for the Open Loop condition, but limited compared to the original one. However, enrichment is always possible if needed. (EN LIMIT).
QPOptimal (Rich) =
QPStoich + EN LIMIT
When the leaning in O.L. strategy is enabled, system compares the Real Petrol Flow to the Optimal Limited one (recalculated by Plug&Drive system) to select on which one calculate the Gas flow.
o When petrol ECU, working on gas, requires an higher enrichment compared to the Optimal Limited one, Sequent P&D will calculate gas flow starting from the Optimal Limited.
QPStoich. + ENO.L.
>
QPOptimal (Rich) QG
o If the Real Petrol Flow required by petrol ECU is lower than the Optimal Limited one, Sequent P&D will not make any cutting and gas flow will be calculated on the Real Petrol Flow
QPStoich. + ENO.L.
<
QPOptimal (Rich) QG
red points are values of lambda oxygen sensor, acquired during self-mapping
green points are actual fuel quantity required by petrol ECU.
o If green points are above the blue line, strategy actually leans, down taking the fuel quantity to
the blue points level, instead of level of green points o For RPM in which green points are below of the blue line, leaning is not done and gas quantity is the same required by petrol ECU, that of green point
Tip-in / Tip-out
B R C G A S E Q U I P M E N T
Cold Strategy
B R C G A S E Q U I P M E N T
Return to Idle
B R C G A S E Q U I P M E N T
B R C
G A S
E Q U I P M E N T
DATA MONITORING
Data Monitoring
B R C G A S E Q U I P M E N T
B R C
G A S
E Q U I P M E N T
EOBD PARAMETERS
EOBD Parameters
B R C G A S E Q U I P M E N T
Tester EOBD
(N Connection)
Communication Protocol ISO 9141 slow ISO 14230 fast ISO 14230 slow SAE J1850 VPM SAE J1850 PWM CAN 250 Kbit/s 11 bits CAN 250 Kbit/s 29 bits CAN 500 Kbit/s 11 bits CAN 500 Kbit/s 29 bits
Type connection K LINE K LINE K LINE --CAN BUS CAN BUS CAN BUS CAN BUS
1 2 3 4 5 6 7 8 9
EOBD Parameters
B R C G A S E Q U I P M E N T
Connection to EOBD PLUG is not necessary for the good working of the vehicle in gas. Some parameters read by EOBD plug are used by Sequent PLUG & DRIVE for further refinement of the fuel control. In addition, these parameters make it easier the manual refinement of gas map, showing the value of the self-adapting parameters in the Map Refinement page. EOBD parameters are also shown and should be recorded during the normal acquisition of gas paramenters in Data Monitoring page.
B R C
G A S
E Q U I P M E N T
ECU VERSION
ECU Version
B R C G A S E Q U I P M E N T
B R C
G A S
E Q U I P M E N T
session