Argomenti trattati
Introduzione
Standard di Riferimento Esigenza operativa Requisiti Contesto Overview Caratteristiche
Il principio
Il principio della Multilaterazione Transponder management
Sotto-Sistemi
Funzioni Componenti
Limplementazione AMS
Funzioni Componenti Performance
Integrazione in A-SMGCS
2
Introduzione
Standard di Riferimento
ICAO, "Aeronautical Telecommunications - Surveillance Radar
and Collision Avoidance Systems," Annex 10 Vol.IV, Third Edition, July 2002
A-SMGCS
Separazione garantita in modo automatico dal sistema attraverso le funzioni di:
Surveillance - Introduzione di Elementi per la gestione dei target cooperanti (localizzazione ed identificazione) - On-Board Situational Awareness Control Guidance - Conflict Prediction, Detection and Resolution - On-Board Alert - Sistemi di guida automatizzati e cooperanti con le funzioni di Surveillance, Control e Planning - On-Board Guidance Route Planning - Sistemi di ausilio per lassegnazione dei percorsi ottimi - Conformance Monitoring
Sorveglianza
Basata su localizzazione ed identificazione automatica derivata e\o ricevuta
Posizione accurata dei target sul sedime aeroportuale Identificazione Automatica Aumento della Accuratezza della Localizzazione Eliminazione dellambiguit sullIdentificazione Maggior Copertura (anche in APRON)
Sorveglianza
Basata su localizzazione ed identificazione automatica
Multilaterazione DGPS Veicolare ADS-B
Transponder Avionici e Veicolari Apparati GPS Veicolari Transponder Avionici e Veicolari
Contesto (1/2)
CO-OPERATING TARGETS SENSOR INPUTS
Surveillance
MONITORING PARAMETERS
GUIDANCE AIDS
Contesto (2/2)
MLAT System Airport Application Attuale A-SMGCS Wide Area Application Evoluzione ATM
Surveillance
Surveillance
Overview (1/2)
Sistema cooperativo per la sorveglianza e lidentificazione
di velivoli (e/o veicoli opportunamente equipaggiati).
Elaborazione degli squitter Modo S standard ed estesi Elaborazione delle repliche asincrone sollecitate da
stazioni dinterrogazione.
10
Overview (2/2)
Il sistema si basa sullinstallazione allinterno ed intorno al sedime aeroportuale, di un opportuno numero di stazioni riceventi e trasmittenti. Non sono richiesti apparati aggiuntivi a bordo dei velivoli. Per il controllo dei veicoli necessario equipaggiarli con transponder ATC
11
Caratteristiche
Accurata stima della posizione del target
Univoca identificazione del target
Frequenza daggiornamento dati pari ad 1 Hz Riuso Apparati di Bordo esistenti Nessun carico aggiuntivo alle trasmissioni radio
12
Il Principio
13
14
15
Mode-S
Short Squitters High Precision Synchronization Extended Squitters TXSINC Roll-Call Replies BDS Registers
Interrogation: All Call Mode A,C Roll Call Mode S
RX RX
ATCRBS
A/C Replies
RX
Plot Extraction Synchronization Logic Tracking Control & Monitoring Recording & Playback
To A-SMGCS
ADS-B
Total Capability
16
Transponder Management
Mode-S Short Squitter (DF11) Mode-S ADS-B Extended Squitter (DF17) Repliche Modo S (Downlink Format 4, 5, 20 e 21) dovute a
interrogazioni selettive
Repliche
ADS-B Extended Squitter/Non-Transponder (Downlink Format 18) inviate da non-Mode-S transponders interrogazioni Roll Call
Repliche 3A/C inviate da transponders Modo S, dovute a Repliche 3A/C inviate da transponders convenzionali, dovute
a interrogazioni All-Call convenzionali
17
Sotto-Sistemi
18
Sotto-sistemi Componenti
Sotto-sistema di Campo
Acquisizione dei segnali emessi dai Transponder Calcolo ed associazione dei Time Stamp Interrogazione selettiva dei Transponder Emissione dei segnali di sincronizzazione dei Clock Performance & Integrity Monitoring
Sotto-sistema di Elaborazione
Target Location & Identification Sincronizzazione dei Clock delle stazioni in campo Supervisor & BITE Recording
Sotto-sistema di Presentazione
Presentazione della diagnostica degli apparati e delle funzioni Presentazione del traffico in tempo reale Playback
19
Stazioni Trasmittenti
Acquisizione dei segnali emessi dai Transponder Calcolo ed associazione dei Time Stamp Interrogazione selettiva dei Transponder
Stazioni di Sincronizzazione
Emissione dei segnali di sincronizzazione dei Clock Emissione dei segnali per Performance & Integrity Monitoring
20
Stazione RX - Funzioni
La principale funzione che svolge una stazione ricevente quella di acquisire, decodificare ed assegnare un time stamp ai segnali emessi dai transponder di bordo.
21
Stazione RX - Componenti
La stazione Ricevente composta da: RF Antenna RF Receiver Unit (1090 MHz) Signal Processor Unit Data Link Unit BITE
22
Stazione TX - Funzioni
Stesse funzioni di una stazione ricevente con laggiunta ricevuti fornite della possibilit di emettere La carico interrogazioni selettive in base ai comandi dallelaboratore allunit trasmittente centrale. in generazione delle sequenze dinterrogazione allelaboratore di segnale.
23
Stazione TX - Componenti
La stazione Ricevente composta da: RF Antenna RF Receiver Unit (1090 MHz) RF Transmission Unit (1030 MHz) Signal Processor Unit Duplexer Data Link Unit BITE
24
Rx3
Rx4
26
Componenti Elaborazione
Target Location & Identification Supervisor & BITE (Control & Monitoring) Recording & Playback Clock Offset Alignment Interrogation Scheduling Tracking
27
Limplementazione AMS
28
Limplementazione AMS
FieldSection
Remote Unit
Remote Unit
Remote Unit
Remote Unit
Multilateration LAN
CD R M - O C R M D- O
LAN Switch
ProcessingSection
CPF
VT520 DisplayTerminal
CPF
Op LAN
C -R M D O
1000x1000
MDT Display
29
Sotto-sistema di Campo
FieldSection
Remote Unit
Remote Unit
Remote Unit
Remote Unit
Multilateration LAN
C -R D OM C- R M D O
LAN Switch
ProcessingSection
CPF
VT520 DisplayTerminal
CPF
Op LAN
C- R M D O
1000x1000
MDT Display
RX Stations
RF Antenna RF Filter Unit Freq. Synthesizer Unit OVEN Clock Unit Digital Processing Unit Redundant PWR Supply 19 rack mount case No Break PWR Supply
RTX Stations
RF Antenna RF Filter Unit Duplexer Power Amplifier Unit Modulator Unit Freq. Synthesizer Unit OVEN Clock Unit Digital Processing Unit Redundant PWR Supply 19 rack mount case No Break PWR Supply 1090 MHz Signals Acquisition 1030 MHz Tx Interrogations TOA Computation Real Time BITE Remote Configurable Functions
TX or SGU Stations
RF Antenna RF Filter Unit Power Amplifier Unit Modulator Unit Digital Processing Unit Redundant PWR Supply 19 rack mount case No Break PWR Supply
1090 MHz Signals Acquisition TOA Computation Real Time BITE Remote Configurable
1090 MHz Synchr. Squitter (SGU) 1030 MHz Tx Interrogation (TX) Real Time BITE Remote Configurable
Legenda Equipment
30
Components
Stazione RX - Caratteristiche
Antenna: Omni with 6 dB gain. Directive type can also be
used
Channel: 1090 MHz Bandwidth: 15 MHz Sensitivity (MTL): configurable, min. better than 60 dBm Dynamic range: better than 60 dB Reply type: Mode A/C, Mode-S (DF 4/ 5/ 11/ 17/ 18/ 20/ 21)
Elettriche Alimentazione: 85 - 255 VAC, 47 Hz .. 63 Hz AC Assorbimento: < 50 W Ambientali Temperature: -50 .. +70 C Humidity: up to 97% condensing Fisiche Installazione in Rack 19
non
Interfaces
1 Ethernet 10/100 BaseT (IEEE 802.3) 1 Infrared port for local configuration 1 RS232 port for local configuration
(*) Patent-pending
31
Stazione TX - Caratteristiche
Tx Interrogator
Antenna: Omni with 6 dB gain. Directive type can
also be used
Channel: 1030 MHz Bandwidth: ICAO compliant Interrogator Type: A/C All Call, UF4/5, UF20/21
(option)
Elettriche Potenza di uscita: 48 dBm max Alimentazione: 220V 50Hz AC Assorbimento: < 50 W Ambientali Temperatura di servizio: -50 .. +70C Umidit: fino a 97% (non condensing) Fisiche Installazione in Rack 19
Interfaces
1 Ethernet 10/100 BaseT (IEEE 802.3) 1 Infrared port for local configuration 1 RS232 port for local configuration
32
Channel: 1090 MHz Bandwidth: ICAO compliant Squitter type: DF11 or DF18 Squitter rate: configurable, 2 Hz max ICAO/Non-ICAO
local/remote Address: configurable by
Elettriche Potenza di uscita: 48 dBm max Alimentazione: 220V 50Hz AC; 9-12 VDC Ambientali Waterproof encapsulation Fisiche Installazione in Rack 19 o trasportabile
Interfaces
1 Ethernet 10/100 BaseT (IEEE 802.3) 1 Infrared port for local configuration 1 RS232 port for local configuration
33
Sotto-sistema di Elaborazione
Central Processing Function (CPF) Target Location & Identification Supervisor & BITE
FieldSection
Recording
Remote Unit
Remote Unit
Remote Unit
Remote Unit
Multilateration LAN
C -R M D O C -R M D O
LAN Switch
ProcessingSection
CPF
VT520 DisplayTerminal
CPF
Op LAN
C -R M D O
1000x1000
MDT Display
34
Questa procedura permette di ottenere stime molto accurate in tempi di elaborazione molto brevi.
35
36
Sofisticati algoritmi di calibrazione consentono di ottenere stime del tempo di ricezione delle repliche con incertezze inferiori ad un nano-secondo (Kalman filtering function)
37
Reply rate maggiore o uguale ad 1 Hz Forti accelerazioni positive e negative Cambi di direzione repentini Plot ricevuti in modalit asincrona Target con aeromobili) dinamiche sostanzialmente differenti (veicoli e
39
Smoothing
La funzione di smoothing si basa su una logica adattiva (Kalman) per il calcolo della correzione da applicare alla nuova posizione misurata.
Inizializzazione Tracce
Ogni volta che la logica di correlazione fallisce su un nuovo plot ricevuto, questo viene mantenuto come possibile base per linizializzazione di una nuova traccia. Se questo plot viene seguito da una serie di plot successivi che correlano con questa nuova traccia tentative, questa diviene traccia attiva. Se questo non avviene la traccia tentative viene scartata.
Cancellazione Tracce
Le tracce che non ricevono nuovi contributi dalla funzione di correlazione vengono cancellate dopo un certo numero di battute attese e non confermate.
40
Sotto-sistema di Presentazione
Multilateration Display Terminal
Presentazione della diagnostica degli apparati e delle funzioni Presentazione del traffico in tempo reale Playback
FieldSection
Remote Unit
Remote Unit
Remote Unit
Remote Unit
Multilateration LAN
C -R M D O C -R M D O
LAN Switch
ProcessingSection
CPF
VT520 DisplayTerminal
CPF
Op LAN
C -R M D O
1000x1000
MDT Display
41
42
MDT opera un monitoraggio costante del segnale di stato (BITE) che ogni apparto invia periodicamente o ad evento. In questo modo loperatore ha sotto costante controllo lo stato funzionale di ogni componente il sistema.
43
Tutti i dati in uscita dal CPF e tutti i messaggi di stato degli apparati vengono costantemente registrati dal sistema. I dati di uscita del CPF possono essere utilizzati per riprodurre fedelmente sul display di MDT una situazione di traffico precedente (playback).
44
System Performance
45
Copertura
La copertura di un sistema di multilaterazione dipende da due fattori:
Copertura della singola stazione Posizionamento sul campo delle stazioni Il sistema dunque adatto per la copertura di aree limitate come a quella di aree molto estese (wide area application)
46
Capacit
Il sistema di multilaterazione in grado di processare oltre 300 target simultaneamente presenti nella sua area di copertura, mantenendo un rate aggiornamento dati di 1 report al secondo.
47
48
49
Position Accuracy
Laccuratezza dipende da due fattori:
North Zone
South Zone
51
Integrazione in A-SMGCS
52
Integrazione in A-SMGCS
Plots & Tracks
Controller Display
Legenda Equipment
Benefits Data
53
Eastwood House, Glebe Road Chelmsford, Essex CM1 1QW England, United Kingdom T+44 (0) 1245 702702 F+44 (0) 1245 702700
Via Tiburtina Km 12,400 00 131 Roma, Italia T+39 06 41501 F+39 06 4131133 www.amsjv.com
The copyright in this document is owned by the companies of Alenia Marconi Systems and may not be reproduced without written consent. Alenia Marconi Systems Limited 2003 54