Met One BAM-1020

ECRD Publications

US-EPA

Equivalent Method

Met One BAM-1020 is a US-EPA designated beta gauge Instrument used world wide. EPA Designation vide EQPM-0798-122

Automatically measures Zero and Reference Mass value in each cycle. Does not require the use of correction factors. Best accuracy of all beta models.
C
ECRD Publications

BAM-1020 Advantages
Continuously samples and measures ambient air for particulate matter. 45 day continuous operation between filter tape changes. Accessories available for measuring PM2.5 and TSP. Heated Probe system to avoid moisture condensation in areas having high Humidity.

ECRD Publications

Beta rays are measured through clean filter tape. Air containing particulate is sampled and deposited on the filter tape. Beta rays are measured through dirty filter tape. The difference between the two measurements is proportional to the mass concentration.
3/31/2012
C
ECRD Publications

Theory of Operation

Beta Gauge Advantages


Time proven, stable technology: beta gauges have been in use for over 60 years. Beta attenuation technique is simple, easy to use, and requires less maintenance than other methods. Fewer site trips required, ideal for remote deployment. Met One beta gauges are manufactured and supported from the United States.

3/31/2012
C
ECRD Publications

Seasonal and geographical correction factors are not needed. It is not necessary to calibrate the beta measurement system in the field. BAMs provide excellent agreement with gravimetric reference standards when properly maintained and operated. Beta technology is virtually unaffected by the chemical composition of the sampled particulate.

Beta Gauge Advantages

3/31/2012
C
ECRD Publications

BAM-1020 Advantages
Continuously samples and measures ambient air for particulate matter. Designed to predict the mass concentration measured by manual gravimetric samplers with the highest accuracy. Does not require the use of correction factors

3/31/2012
C
ECRD Publications

BAM-1020 Advantages
60 day continuous operation between filter tape changes. Designed for long term operation at a fixed installation. Powerful integrated 6 channel data logger compatible with a wide array of meteorological sensors. Best accuracy of all beta models.

3/31/2012
C
ECRD Publications

Simplicity Measurement System


The BAM-1020 measurement system consists of a few simple components:
Carbon 14 Beta source Filter tape support Photomultiplier tube detector Preamp circuitry

3/31/2012

BAM Comparison to EPA Reference for PM2.5

3/31/2012