Vous êtes sur la page 1sur 54

UAG Hardware System

www.huawei.com

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

References

SGSN V8R8 UAG product manual

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page1

Objectives

Upon completion of this course, you will be able to:

Describe UAG product networking Outline UAG logical structure Outline UAG hardware structure Outline UAG board function Describe UAG signalling and data flow

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page2

Contents
1. UAG Overview 2. UAG Hardware Structure 3. UAG Signalling and Data Flows

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page3

Contents
1. UAG Overview 2. UAG Hardware Structure 3. UAG Signalling and Data Flows

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page4

The Location of UAG

UAG

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page5

The Function of UAG


Forwarding the CS signalling and Service Data Forwarding the PS signalling and Service Data UAP Authentication Functions of the NTP Client

Routing Function

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page6

Contents
1. UAG Overview 2. UAG Hardware Structure 3. UAG Signalling and Data Flows

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page7

Contents
2. UAG Hardware Structure
2.1 UAG Logical Structure 2.2 UAG Hardware Structure 2.3 UAG Switching Subsystem 2.4 UAG OAM Subsystem 2.5 UAG Clock Subsystem 2.6 UAG Interface Subsystem

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page8

UAG Logical Structure


AP/MGW/ MSC Server SGSN/NTP /AHR

Data forwarding subsystem

NTP subsystem

Signalling processing subsystem

ATM switching subsystem

OAM subsystem

M2000/ LMT

Clock subsystem

BITS

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page9

UAG Subsystem Function

O&M Subsystem

The O&M subsystem offers the external O&M maintenance interface and implements the functions of system maintenance, configuration, performance, alarm, and log. The hardware function is implemented by the UOMU and UFSU boards.

Clock Subsystem

The clock subsystem obtains clock signals from the BITS and the STM-1/STM-4 optical interfaces, and offers the stratum-2 clock to the STM-1/STM-4 optical interface of the UAG.

The hardware function is implemented by the UCKI board.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page10

UAG Subsystem Function

ATM Switching Subsystem

The ATM switching subsystem implements the ATM exchange and interconnection among subracks. The hardware function is implemented by the URCU, UPIU, and UFCU boards.

NTP Subsystem

The NTP subsystem implements the function of the NTP client and obtains timing information on the IP network from the NTP server.
The hardware function is implemented by the UGTP board.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page11

UAG Subsystem Function

Signalling Processing Subsystem

The signalling processing subsystem processes the eIu and Iu interface signalling, and authorizes and manages the UAP. The hardware function is implemented by the UASU board.

Data Forwarding Subsystem

The data forwarding subsystem offers the eIu interface, the Iu interface, the Hg interface, and the interface from the UAG to the NTP server. It forwards user data between the eIu interface and the Iu interface. The hardware function is implemented by the UAFU and UPIU boards

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page12

Contents
2. UAG Hardware Structure
2.1 UAG Logical Structure 2.2 UAG Hardware Structure 2.3 UAG Switching Subsystem 2.4 UAG OAM Subsystem 2.5 UAG Clock Subsystem 2.6 UAG Interface Subsystem

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page13

UAG Cabinet

Power distribution box

UAG system uses the Huawei N68-22 cabinet, which complies with the IEC297 and IEEE standards.

U A F U

U A F U

U A S U

U A S U

U A S U

U A S U

U R C U

U R C U

U A S U

U A S U

U A S U

U A S U

U A S U

U A S U

U A L U

U P W R

U P W R

PSM subrack Air deflector

U A F U

U A F U

U A S U

U A S U

U A S U

U A S U

U R C U

U R C U

U A S U

U A S U

U A S U

U A S U

U A S U

U A S U

U A L U

U P W R

U P W R

PSM subrack Air deflector

U A F U

U A F U

U A S U

U A S U

U A S U

U A S U

U R C U

U R C U

U A S U

U A S U

U A S U

U A S U

U A S U

U A S U

U A L U

U P W R

U P W R

PSM subrack Air deflector

U A F U

U A F U

U A F U

U A F U

U F C U

U F C U

U R C U

U R C U

U O M U

U O M U

U G T P

U G T P

U A L U

U P W R

U P W R

PSM subrack Dummy panel

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page14

UAG Subrack: Switching Subrack


U L A N U A S U
0

U L A N U A S U
1

U P I U U A F U
2

U P I U U A F U
3

U U U U U P P B A B I I I C I U U U U U U U U U R F F R C C C C U U U U
4 5 6 7 8

U A C U

U F S U
U O M U

U F S U
U O M U

U C K I

U C K I

U G T P

U G T P

U A L U

U P W R U P W R

U P W R U P W R

9 10 11 12 13 14 15 16 17,18 19,20

The switching subrack is configured with the UOMU and UFCU boards. Only one switching subrack is required. The fundamental functions of the switching subrack are listed as follows:

Forwarding data among the PSM subracks Offering the O&M interfaces
Page15

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

UAG Subrack: Extension Subrack


U P I U U A F U
0

U P I U U A F U
1

U A S U
2

U A S U
3

U A S U
4

U A S U
5

U B I U U R C U
6

U U U U A B A P C I C I U U U U U U R A C F U U
7 8

U P I U U A F U

U A S U

U A S U

U A S U

U A S U

U A L U

U P W R U P W R

U P W R U P W R

9 10 11 12 13 14 15 16 17,18 19,20

The SGSN9810 can configure 0 to 3 extension subracks. Extension subracks process only services.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page16

Contents
2. UAG Hardware Structure
2.1 UAG Logical Structure 2.2 UAG Hardware Structure 2.3 UAG Switching Subsystem 2.4 UAG OAM Subsystem 2.5 UAG Clock Subsystem 2.6 UAG Interface Subsystem

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page17

UAG Switching Subsystem

U B I U U R C U Extension subrack

U B I U U R C U

U P I U
U F C U

Switching subrack

U B I U U R C U Extension subrack

Fiber
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page18

Communication Within Subracks

The different boards of the same subrack will use the bus of the back board to communicate with each other.
U P I U
U A F U U A S U U G T P

BUS

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page19

Communication Between Subracks

Different boards of different subrack will communicate to each other via URCU/UFCU.
Switching

BUS U A S U

U B I U U R C U

Fiber

U P I U U F C U

Fiber

U B I U U R C U

Extension

BUS U G T P

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page20

UFCU

UFCU:

The Frame Connect Unit (UFCU) is the switching center of UAG.

The UFCU can be inserted in slots 05 and 1015 in the PSM switching subrack in the front position.
RST
10/100BT

Interface COM 10/100BT

Description RJ45 serial port (RS232) 10/100 Mbit/s test network port

Function Provides the test function of the UFCU to external devices. Provides the test function of the UFCU to external devices.

ALMRUN ACT
COM

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page21

UFCU
Indicator RUN Color Green Description Board running indicator Meaning FPGA loading: flashing in the frequency of 1 Hz Normal running: flashing in the frequency of 0.5 Hz OFF: board working normally ON: board failure OFF: standby board ON: active board OFF: board working normally ON: Before clipping the ejector lever after inserting the board into the subrack After loosing the ejector lever when the board is switched on Compliable to the hot swapping specifications. You can pull out the UFCU when this indicator is on. Normal State Flashing in the frequency of 0.5 Hz OFF -

ALM ACT

Yellow Green

Board fault indicator 1+1 active/standby state indicator Hot-swap indicator (at the bottom of the panel)

Blue indicator

Blue

OFF

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page22

UFCU Operation Environment


Optical port Optical port

The UFCU communicates with the UPIU, its back board, through the high speed serial port and the configuration network port. The UFCU communicates with the other boards in the subrack through the data bus. The UFCU communicates with the URCU in the PSM service subrack through the fiber led out through the UPIU.

UAIC

UAIC

UPIU

Conf. netowrk port

High-speed serial port

U R C U UFCU

Data bus

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page23

UPIU

RUN ACT

ALM LNK

UPIU:

RX TX M/S-LINK

The back board of UFCU/UAFU. Providing Ethernet or Giga bit/s or ATM interface by using different PMC board:

P0

P1

P2

UEEC

P3

UEEC: 10M/100M Ethernet port; UEFC: 1000M Ethernet( Giga bps) port; UAIC: ATM optical port.
P0

P1 UEFC/

UPIU only use UAIC PMC board when work with UFCU.

P2

UAIC

P3

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page24

Contents
2. UAG Hardware Structure
2.1 UAG Logical Structure 2.2 UAG Hardware Structure 2.3 UAG Switching Subsystem 2.4 UAG OAM Subsystem 2.5 UAG Clock Subsystem 2.6 UAG Interface Subsystem

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page25

UAG OAM Subsystem


LMT Upper Eth port Lower Eth port

Eth Fiber Bus Serial cable

Alarm box
COM port

UOMU/UFSU

UFCU/UPIU

ULAN

URCU/UBIU

URCU/UBIU

UASU.. UASU.. Extension

UGTP.. UAFU.. Switching

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page26

UAG OAM Subsystem

Normal maintenance route:

LMTUOMUUFCUURCUUGTP/UASU etc.

Software loading route:

(1) LMTUOMUULANURCU( switching subrack ) UFCU ; then;

(2) UOMUUFCUURCUUGTP/UASU etc.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page27

UOMU

UOMU is the OAM center of UAG:

Configuration management, performance management, security management and log management

Query control User or signal tracing


RST

ALM RUN ACT

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page28

COM

UFSU
RUN ALM PWR HD

UFSU: Flash Disk Storage Unit, the backboard of UOMU.

RX TX
ATM 155M

Supports level conversion of the 2-port asynchronous serial port signals from the UOMU and provides physical interfaces to two asynchronous serial ports.
COM1

Holds the hard disk of the UOMU and stores system


details such as system configuration data.

COM2

Provides external optical port and network port for the UOMU.

10/100M0 10/100M1

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page29

URCU

URCU: Subrack Control Unit, is the OAM center of a subrack.

Each PSM subrack is configured with two URCU boards that are inserted in slot 6 and slot 8. The URCU boards are configured in 1+1 backup mode.
10/100BT COM

URCU provide the data transport channel of


different boards in the same subrack or in different subrack.

RST

ALM RUN DOMADOMB

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page30

UBIU: Back Interface Unit, is the backboard of URCU. The UBIU provides external ports for the URCU:

LNK ALM PWR RX TX ATM155

Ethernet port 155Mbit/s optical port

UBIU also handle the clock signal:

Receives the 8K clock signal from the sub-board UFIU of the URCU. ( For extension subrack UBIU) Receives the 8K clock signal from UCKI. ( For switching subrack UBIU)

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page31

2M_OUT2 8K_IN 8K_OUT COM1 COM2 COM2+ 10/100M

Serial ports

2M_OUT1

UBIU

UACU

UACU: Auxiliary Control Unit, cooperate with URCU to perform the management of a subrack.

Each PSM subrack is configured with two UACU


boards inserted in slot 7 and slot 9 in the rear position.

The URCU in slot 6 is used in co-ordination with the UACU in slot 9 and the URCU in slot 8 is used in coordination with UACU in slot 7.
DOMB DOMA

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page32

URCU/UBIU/UACU Cooperation
Optical port Optical port UBIU UBIU

Optical port electric signal

Async. serial port


UACU UACU

Bus A

Bus B

U SPB F I U

U R C U

U F I U

U R C U SPB

SPB: Serv ice Processing Board


Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page33

Contents
2. UAG Hardware Structure
2.1 UAG Logical Structure 2.2 UAG Hardware Structure 2.3 UAG Switching Subsystem 2.4 UAG OAM Subsystem 2.5 UAG Clock Subsystem 2.6 UAG Interface Subsystem

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page34

UAG Clock Subsystem


External clock input

UCKI

PSM switching subrack

UBIU Internal clock bus

UPIU STM-1 PSM service subrack

UPIU STM-1 PSM service subrack

...

UPIU STM-1

...

PSM service subrack

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page35

UAG Clock Subsystem

In the PSM switching subrack, the UBIU receives clock signals from the UCKI and synchronizes these signals to the UPIU in this subrack through the internal clock bus.

The UPIU multiplexes the clock signals to the STM-1 fiber and sends the system synchronization clock to each PSM service subrack. This guarantees the clock synchronization of the whole system.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page36

UCKI

UCKI: Clock Unit, It is inserted in slots 13 and 15 in the PSM basic subrack. Each UCKI occupies two back board slots.

RUN ALM ACT RST BITS1 BITS2 LINE1 LINE2 1 3 5 7 9 11 13 15 2 4 6 8 10 12 14 16

Interface BITS1 BITS2 LINE1

Description 2 MHz or 2 Mbit/s clock input port 2 MHz or 2 Mbit/s clock input port E1 2 MHz clock input port

Function Extract 2 MHz or 2 Mbit/s clock signals as the reference source. Extract 2 MHz or 2 Mbit/s clock signals as the reference source. Extract 2 MHz clock signals as the reference source.

LINE2

E1 2 MHz clock input port

Connects the UEPI to extract 2 MHz clock signals as the reference source.
Provides the clock source for the UEPI in various subracks.

1 to 16

Sixteen 8 kHz clock output ports

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page37

Clock Cable Connection

Clock cable BITS1 Clock cable 1 UCKI 8k_in

UBIU (Switching subrack)

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page38

Contents
2. UAG Hardware Structure
2.1 UAG Logical Structure 2.2 UAG Hardware Structure 2.3 UAG Switching Subsystem 2.4 UAG OAM Subsystem 2.5 UAG Clock Subsystem 2.6 UAG Interface Subsystem

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page39

UAG Interface Subsystem


AP U P I U U A F U U A S U Switching subsystem U G T P Eth Fiber U A S U U A F U U P I U PS U A S U U A F U U P I U CS

eIU interface

Iu-CS interface

AHR/ NTP

U P I U

U A F U

U A S U

APM/NTP

Iu-PS interface

Internal connection
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page40

UAG Interface Subsystem


eIu interface Iu-CS, Iu-PS interface
UEEC/ UEFC UAIC

UPIU

Conf. network port

High-speed serial port

U A S U UAFU

U G T P

Data bus

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page41

UAFU

UAFU: UMTS AG Forwarding Unit, is the forwarding front board of the AG.

Forwarding the data on the CS and PS user planes between the AG, the MGW, and the SGSN.
Forwarding the signalling on the elu and Iu interfaces to the UASU for processing.
RST
10/100BT

The UAFU works in the 1+1 active/standby mode. The number of the UAFUs depends on the number of subscribers. A maximum of 10 couples of UAFUs can be configured in the system.

ALMRUN ACT
COM

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page42

UPIU

RUN ACT

ALM LNK

UPIU:

RX TX M/S-LINK

The back board of UFCU/UAFU. Providing Ethernet or Giga bit/s or ATM interface by using different PMC board:

P0

P1

P2

UEEC

P3

UEEC: 10M/100M Ethernet port; UEFC: 1000M Ethernet( Giga bps) port; UAIC: ATM optical port.
P0

P1 UEFC/ P2 UAIC

P3

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page43

UASU

UAFU: UMTS AG Signal Unit, is the service signal processing board.


Handling of CS and PS call signalling;


RNC agent; AP management; MSISDN access control; resource management.
10/100BT

RST

The UASU works in the 1+1 active/standby mode. The number of the UAFUs depends on the number of subscribers.

ALMRUN ACT
COM

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page44

UGTP

UGTP: GTP Processing Unit

Processes the GTP user plane signalling, and stores and manages the user PDP contexts.

NTP function; IPsec function.


RST
10/100BT

ALMRUN ACT
COM

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page45

Contents
1. UAG Overview 2. UAG Hardware Structure 3. UAG Signalling and Data Flows

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page46

Iu-CS Signalling Flow


MSC Server AP U P I U U A F U U A S U U B I U U R C U U P I U U F C U U B I U U R C U U A S U U P I U U A F U

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page47

Iu-CS Data Flow


MGW AP U P I U U A F U U A S U U B I U U R C U U P I U U F C U U B I U U R C U U A S U U P I U U A F U

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page48

Iu-CS Signalling Flow


SGSN AP U P I U U A F U U A S U U B I U U R C U U P I U U F C U U B I U U R C U U A S U U P I U U A F U

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page49

Iu-PS Data Flow


SGSN AP U P I U U A F U U A S U U B I U U R C U U P I U U F C U U B I U U R C U U A S U U P I U U A F U

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page50

APM/NTP Signalling Flow


AP U P I U U A F U U A S U NTP U P I U U A F U NTP flow U G T P

APM flow

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page51

Summary

UAG is consist of OAM subsystem, ATM switching subsystem, clock subsystem, NTP subsystem, data forwarding subsystem and signalling processing subsystem.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page52

Thank you
www.huawei.com

Vous aimerez peut-être aussi