Vous êtes sur la page 1sur 12

Transient Stability Improvement of SMIB With Unified Power Flow Controller

By

THAKUR SANDEEP SINGH(08E51A0258) O.RAGESH(08E51A0236) P.V.MAHESH WAR REDDY(08E51A0238)


UNDER THE GUIDANCE OF

Mr. s.Hari prasad

PROJECT OVERVIEW
Objective of the Project
Introduction Block Diagrams different stages in the project Advantages Applications Future work

Objective of the Project


The focus of this project

is on a FACTS device known as the

Unified Power Flow Controller (UPFC)


which can provide simultaneous control of basic power system

parameters like voltage, impedance and phase angle


In this project, we have two simulation models of single machine

infinite bus (SMIB) system, i.e. with & without UPFC.


These simulation models have been incorporated into MATLAB

based Power System Toolbox (PST) for their transient stability analysis.

INTRODUCTION
A number of flexible alternating current transmission systems

(facts) controllers are available today due to the rapid development in the field of power electronics.
Generally each of these controllers can act only on one of the

three parameters(voltage, impedance and angle),that determine the power flow through a transmission line.
But Unified Power Flow Controller (UPFC) is such a versatile

FACTS device that has the capability of controlling all the three parameters simultaneously

an approach to solve first-swing stability problem using UPFC, along

with comprehensive analysis.


analyzed that FACTS devices are used to control power flow through

a line and damp out oscillations.


Series controllers are more effective to control current/ power flow

through a line and damp out oscillations.


UPFC is a series shunt controller that can be used to control active &

reactive power through a line and line voltage control can be done simultaneously or individual.
UPFC is also used to analyze transient stability of a single machine

system or multi machine system.

BLOCK DIAGRAM

Different stages in the project


The different stages in the project are given below: Symmetrical Three Phase Fault on the Transmission Line:
Fault at receiving end:

Single Machine Infinite Bus (SMIB) System without UPFC. Single Machine Infinite Bus (SMIB) System with UPFC at receiving end.

Symmetrical Three Phase Fault on the Transmission Line :


Fault at Middle of Transmission line:

Single Machine Infinite Bus (SMIB) System without UPFC.

Single Machine Infinite Bus (SMIB) System with UPFC


at Receiving end.

ADVANTAGES
Unified Power Flow Controller (UPFC) is such a versatile FACTS

device that has the capability of controlling all the three parameters simultaneously.
The developed power analysis toolbox (PAT), is a very flexible and

modular tool for load flow, transient and small-signal analysis of


electric power systems.
It improves the transient stability of the transmission lines.

APPLICATIONS

ANY QUERIES

THANK YOU

Vous aimerez peut-être aussi