METHODE SUPERFICIELLE
Algorithme de vérification des conditions d’autocurage EU
Débit des tuyaux (litre /seconde) (formule
de BAZINE)
Pente =1% Pente = 2 % Pente = 3 % Pente = 4 % Pente = 5 %
(mm) A B A B A B A B A B
75 - - - - 2.10 3.15 2.43 3.64 2.71 4.06
94 2.30 3.45 3.26 4.89 3.99 5.98 4.61 6.01 5.16 7.74
100 2.68 4.02 3.60 5.70 4.65 6.97 5.38 8.04 5.99 8.98
108 3.27 4.90 4.72 7.08 5.75 8.62 6.63 9.94 7.41 11.11
125 3.85 7.42 7.00 10.50 8.58 12.87 9.91 14.86 11.10 16.60
135 6.08 9.12 8.67 13.00 10.56 15.84 12.23 18.34 13.66 20.49
150 8.17 12.25 11.54 17.31 14.16 21.24 16.30 24.45 18.20 27.30
175 12.40 10.60 17.50 26.26 21.50 32.20 24.80 37.20 27.70 41.50
200 17.86 26.79 25.27 37.80 30.85 46.27 35.64 53.46 39.87 59.80
225 22.50 36.70 34.60 51.90 42.40 63.60 49.00 73.50 54.80 82.20
250 32.55 48.82 45.97 68.95 56.50 84.75 65.09 97.63 72.77 109.15
300 53.04 79.56 75 112.6 91.74 137.6 106.0 159.1 118.4 177.67
5 1 8 2 5